Combined flow-based imaging assessment of optimal cardiac resynchronization therapy pacing vector: a case report
Open Access
- 25 May 2019
- journal article
- case report
- Published by Springer Nature in Journal of Medical Case Reports
- Vol. 13 (1) , 161
Abstract
There are still many pendent issues about the effective evaluation of cardiac resynchronization therapy impact on functional mitral regurgitation. In order to reduce the intrinsic difficulties of quantification of functional mitral regurgitation itself, an automatic quantification of real-time three-dimensional full-volume color Doppler transthoracic echocardiography was proposed as a new, rapid, and accurate method for the assessment of functional mitral regurgitation severity. Recent studies suggested that images of left ventricle flow by echo-particle imaging velocimetry could be a useful marker of synchrony. Echo-particle imaging velocimetry has shown that regional anomalies of synchrony/synergy of the left ventricle are related to the alteration, reduction, or suppression of the physiological intracavitary pressure gradients. We describe a case in which the two technologies are used in combination during acute echocardiographic optimization of left pacing vector in a 63-year-old man, Caucasian, who showed worsening heart failure symptoms a few days after an implant, and the effect of the device’s optimization at 6-month follow-up. The degree of realignment of hemodynamic forces, with quantitative analysis of the orientation of blood flow momentum (φ), can represent improvement of fluid dynamics synchrony of the left ventricle, and explain, with a new deterministic parameter, the effects of cardiac resynchronization therapy on functional mitral regurgitation. Real-time three-dimensional color flow Doppler quantification is feasible and accurate for measurement of mitral inflow, left ventricular outflow stroke volumes, and functional mitral regurgitation severity. This clinical case offers an innovative and accurate approach for acute echocardiographic optimization of left pacing vector. It shows clinical utility of combined three-dimensional full-volume color Doppler transthoracic echocardiography/echo-particle imaging velocimetry assessment to increase response to cardiac resynchronization therapy, in terms of reduction of functional mitral regurgitation, improving fluid dynamics synchrony of the left ventricle.Keywords
This publication has 17 references indexed in Scilit:
- Automated 3-Dimensional Single-Beat Real-Time Volume Colour Flow Doppler Echocardiography in Children: A Validation Study of Right and Left Heart FlowsCanadian Journal of Cardiology, 2018
- Quantification of Flow by 3D Color Flow Doppler:Canadian Journal of Cardiology, 2018
- Clinical Implications of Three-Dimensional Real-Time Color Doppler Transthoracic Echocardiography in Quantifying Mitral Regurgitation: A Comparison with Conventional Two-Dimensional MethodsJournal of the American Society of Echocardiography, 2017
- Left ventricular pacing vector selection by novel echo-particle imaging velocimetry analysis for optimization of quadripolar cardiac resynchronization device: a case reportJournal of Medical Case Reports, 2016
- Changes in electrical activation modify the orientation of left ventricular flow momentum: novel observations using echocardiographic particle image velocimetryEuropean Heart Journal - Cardiovascular Imaging, 2015
- Mechanotransduction Mechanisms for Intraventricular Diastolic Vortex Forces and Myocardial Deformations: Part 1Journal of Cardiovascular Translational Research, 2015
- Quantification of Mitral Regurgitation by Real Time Three‐Dimensional Color Doppler Flow Echocardiography Pre– and Post–Percutaneous Mitral Valve RepairEchocardiography, 2014
- The vortex—an early predictor of cardiovascular outcome?Nature Reviews Cardiology, 2014
- Automated Quantification of Mitral Inflow and Aortic Outflow Stroke Volumes by Three-Dimensional Real-Time Volume Color-Flow Doppler Transthoracic Echocardiography: Comparison with Pulsed-Wave Doppler and Cardiac Magnetic Resonance ImagingJournal of the American Society of Echocardiography, 2012
- A real-time 3-dimensional digital Doppler method for measurement of flow rate and volume through mitral valve in children: A validation study compared with magnetic resonance imagingJournal of the American Society of Echocardiography, 2005