    Clinical practice and outcome of S-ICD replacement: results from the multicenter rhythm detect registry

    by P I E T R O Palmisano, P Pieragnoli, S Viani, G Nigro, P Francia, M Biffi, P De Filippo, E Pisano, G Bisignani, M Giammaria, et al.

    Background: Subcutaneous implantable cardioverter-defibrillator (S-ICD) therapy is expanding rapidly. However, there are few data on the S-ICD replacement procedure. Objective: The aim of this analysis was to describe the procedure and outcome of S-ICD replacement in clinical practice. Methods: From 2013 to 2022, consecutive patients undergoing de-novo implantation of an S-ICD were enrolled at 66 Italian centers of the Rhythm Detect Registry. We analyzed consecutive patients who required S-ICD replacement. Results: 319 S-ICD generators (49 Cameron, 270 Emblem) were replaced for battery depletion. All the procedures were performed in electrophysiology laboratories, by one or two expert operators. In 118 (37%) cases, the replacement was performed as outpatient procedure. The procedure was performed under local anesthesia with or without conscious sedation in 297 patients (93%). The previous S-ICD generator was in an intermuscular pocket in 195 (61%) patients, and in a subcutaneous pocket in the remaining 124 (39%). 39 (31%) generators were shifted from subcutaneous to intermuscular pocket, and their PRAETORIAN score improved from 43±20 to 34±13 (p=0.007). In most cases (308 (97%)), the defibrillation test was not performed after replacement, but the overall PRAETORIAN score was very low (37±28). The S-ICD system was successfully replaced in all patients and no complications were reported; the procedure duration was 39±16 min and was comparable in the case of generator re-implanted in the same pocket or in case of shift to a new pocket. Conclusions: S-ICD replacement was safe and easy to perform, with no peri-operative complications. In clinical practice the replacement procedure is often an opportunity to optimize the position of the generator

  • Open Access

    Association between amount of biventricular pacing and heart failure status measured by a multisensor implantable defibrillator algorithm

    by L Santini, L Calo, V Bianchi, M Manzo, A Dello Russo, G Savarese, D Pecora, C Amellone, V E Santobuono, R Calvanese, et al.

    Background: Achieving a high biventricular pacing percentage (BiV%) is crucial for optimizing outcomes in cardiac resynchronization therapy (CRT). The HeartLogic index, a multiparametric heart failure (HF) risk score, incorporates implantable defibrillator (ICD)-measured variables and has demonstrated its predictive ability for impending HF decompensation. Purpose: This study aimed to investigate the relationship between daily BiV% in CRT ICD patients and their HF status, assessed using the HeartLogic algorithm. Methods: The HeartLogic algorithm was activated in 306 patients across 26 centers, with a median follow-up of 26 months (25th–75th percentile: 15-37). Results: During the follow-up period, 619 HeartLogic alerts were recorded in 186 patients. Overall, daily values associated with the best clinical status (highest first heart sound, intrathoracic impedance, patient activity; lowest combined index, third heart sound, respiration rate, night heart rate) were associated with a BiV% exceeding 99%. We identified 455 instances of BiV% dropping below 98% after consistent pacing periods. Longer episodes of reduced BiV% (hazard ratio: 2.68; 95% CI: 1.02-9.72; P=0.045) and lower BiV% (hazard ratio: 3.97; 95% CI: 1.74-9.06; P=0.001) were linked to a higher risk of HeartLogic alerts. BiV% drops exceeding 7 days predicted alerts with 90% sensitivity (95% CI [74%-98%]) and 55% specificity (95% CI [51%-60%]), while BiV% ≤96% predicted alerts with 74% sensitivity (95% CI [55%-88%]) and 81% specificity (95% CI [77%-85%]). Conclusions: A clear correlation was observed between reduced daily BiV% and worsening clinical conditions, as indicated by the HeartLogic index. Importantly, even minor reductions in pacing percentage and duration were associated with an increased risk of HF alerts.Time to event

  • Open Access

    Multiparametric Implantable Cardioverter-Defibrillator Algorithm for Heart Failure Risk Stratification and Management: An Analysis in Clinical Practice

    by Leonardo Calò, Valter Bianchi, Donatella Ferraioli, Luca Santini, Antonio Dello Russo, Cosimo Carriere, Vincenzo Ezio Santobuono, Chiara Andreoli, Carmelo La Greca, Giuseppe Arena, et al.

    Background: The HeartLogic algorithm combines multiple implantable cardioverter-defibrillator sensors to identify patients at risk of heart failure (HF) events. We sought to evaluate the risk stratification ability of this algorithm in clinical practice. We also analyzed the alert management strategies adopted in the study group and their association with the occurrence of HF events. Methods: The HeartLogic feature was activated in 366 implantable cardioverter-defibrillator and cardiac resynchronization therapy implantable cardioverter-defibrillator patients at 22 centers. The median follow-up was 11 months [25th–75th percentile: 6–16]. The HeartLogic algorithm calculates a daily HF index and identifies periods IN alert state on the basis of a configurable threshold. Results: The HeartLogic index crossed the threshold value 273 times (0.76 alerts/patient-year) in 150 patients. The time IN alert state was 11% of the total observation period. Patients experienced 36 HF hospitalizations, and 8 patients died of HF during the observation period. Thirty-five events were associated with the IN alert state (0.92 events/patient-year versus 0.03 events/patient-year in the OUT of alert state). The hazard ratio in the IN/OUT of alert state comparison was (hazard ratio, 24.53 [95% CI, 8.55–70.38], P P =0.047). No differences in event rates were observed between in-office and remote alert management. Conclusions: This multiparametric algorithm identifies patients during periods of significantly increased risk of HF events. The rate of HF events seemed lower when clinical actions were undertaken in response to alerts. Extra in-office visits did not seem to be required to effectively manage HeartLogic alerts. Registration: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT02275637.


  • Open Access

    Combined flow-based imaging assessment of optimal cardiac resynchronization therapy pacing vector: a case report

    by A. R. Martiniello, V. Bianchi, G. Tonti, C. Cioppa, V. Tavoletta, A. D’oNofrio, V. M. Caso, G. Pedrizzetti, P. Caso

    There are still many pendent issues about the effective evaluation of cardiac resynchronization therapy impact on functional mitral regurgitation. In order to reduce the intrinsic difficulties of quantification of functional mitral regurgitation itself, an automatic quantification of real-time three-dimensional full-volume color Doppler transthoracic echocardiography was proposed as a new, rapid, and accurate method for the assessment of functional mitral regurgitation severity. Recent studies suggested that images of left ventricle flow by echo-particle imaging velocimetry could be a useful marker of synchrony. Echo-particle imaging velocimetry has shown that regional anomalies of synchrony/synergy of the left ventricle are related to the alteration, reduction, or suppression of the physiological intracavitary pressure gradients. We describe a case in which the two technologies are used in combination during acute echocardiographic optimization of left pacing vector in a 63-year-old man, Caucasian, who showed worsening heart failure symptoms a few days after an implant, and the effect of the device’s optimization at 6-month follow-up. The degree of realignment of hemodynamic forces, with quantitative analysis of the orientation of blood flow momentum (φ), can represent improvement of fluid dynamics synchrony of the left ventricle, and explain, with a new deterministic parameter, the effects of cardiac resynchronization therapy on functional mitral regurgitation. Real-time three-dimensional color flow Doppler quantification is feasible and accurate for measurement of mitral inflow, left ventricular outflow stroke volumes, and functional mitral regurgitation severity. This clinical case offers an innovative and accurate approach for acute echocardiographic optimization of left pacing vector. It shows clinical utility of combined three-dimensional full-volume color Doppler transthoracic echocardiography/echo-particle imaging velocimetry assessment to increase response to cardiac resynchronization therapy, in terms of reduction of functional mitral regurgitation, improving fluid dynamics synchrony of the left ventricle.


  • Open Access

    Left ventricular pacing vector selection by novel echo-particle imaging velocimetry analysis for optimization of quadripolar cardiac resynchronization device: a case report

    by Alfonso Roberto Martiniello, Gianni Pedrizzetti, Valter Bianchi, Giovanni Tonti, Antonio D’onofrio, Pio Caso

    The availability of pacing configurations offered by quadripolar left ventricular leads could improve patients’ response to cardiac resynchronization therapy; however, the selection of an optimal setting remains a challenge. Echo-particle imaging velocimetry has shown that regional anomalies of synchrony/synergy of the left ventricle are related to the alteration, reduction, or suppression of the physiological intracavitary pressure gradients. These observations are also supported by several numerical models of the left ventricle that have shown the close relationship between wall motion abnormalities, change of intraventricular flow dynamics, and abnormal distribution of forces operating on the ventricular endocardium. A 73-year-old white man in New York Heart Association III functional class with an ejection fraction of 27.5 % did not improve after 1 month of cardiac resynchronization therapy. Five configurations were tested and settings were defined by optimizing intraventricular flow. After 6 months, he became New York Heart Association II class with left ventricular ejection fraction of 53.2 %. The abnormal dynamic of pressure gradients during the cardiac cycle, through biohumoral endocrine, autocrine, and paracrine transduction, may lead to structural changes of the myocardial walls with subsequent left ventricular remodeling. The echo-particle imaging velocimetry technique may be useful for elucidating the favorable effects of cardiac resynchronization therapy on intraventricular fluid dynamics and it could be used to identify appropriate pacing setting during acute echocardiographic optimization of left pacing vector.