Third Body Wear of an All-Polymer, PEEK-OPTIMA™ on Ultra-High-Molecular-Weight Polyethylene Total Knee Replacement
Open Access
- 5 March 2025
- journal article
- research article
- Published by MDPI AG in Bioengineering
- Vol. 12 (3) , 261
Abstract
Experimental wear simulation of a PEEK-OPTIMA™ polymer-on-UHMWPE total knee replacement has shown equivalent UHMWPE wear to conventional knee replacement materials (cobalt chrome-on-UHMWPE) when tested in a clean environment. The aim of this study was to experimentally investigate the wear of this all-polymer total knee replacement under third body wear conditions. Three PEEK-OPTIMA™ and three cobalt chrome femoral components articulating against all-polyethylene tibial components were tested in a knee simulator. One million cycles of wear simulation was carried out in clean lubricant under conditions replicating walking followed by one million cycles with the lubricant contaminated with porcine bone particles, then one million cycles with PMMA cement particles. UHMWPE wear was determined gravimetrically. Statistical analysis compared UHMWPE wear against PEEK femoral components to cobalt chrome. In clean lubricant and with bone particles in the lubricant, there was no significant difference (p > 0.05) in UHMWPE wear against the different femoral component materials, and wear rates were similar under both conditions. With PMMA particles, there was a dramatic increase in UHMWPE wear for both knee replacement systems but no significant difference (p > 0.05) in UHMWPE wear between the femoral component materials. This is the first study to investigate wear of an all-polymer knee under third body wear conditions.Keywords
Funding Information
- Invibio Knees Ltd. (EP/N00941X/1)
- Engineering and Physical Sciences Research Council (EP/N00941X/1)
This publication has 45 references indexed in Scilit:
- Wear mechanism and debris analysis of PEEK as an alternative to CoCrMo in the femoral component of total knee replacementFriction, 2023
- The biological response to orthopaedic implants for joint replacement: Part I: MetalsJournal of Biomedical Materials Research Part B: Applied Biomaterials, 2016
- Wear in total knee arthroplasty—just a question of polyethylene?International Orthopaedics, 2013
- The influence of third-body particles on wear rate in unicondylar knee arthroplasty: a wear simulator study with bone and cement debrisJournal of Materials Science: Materials in Medicine, 2013
- Macrophage reactivity to different polymers demonstrates particle size‐ and material‐specific reactivity: PEEK‐OPTIMA®particles versus UHMWPE particles in the submicron, micron, and 10 micron size rangesJournal of Biomedical Materials Research Part B: Applied Biomaterials, 2011
- Präklinische Ergebnisse beschichteter Knieimplantate für AllergikerDer Orthopäde, 2010
- Patient Satisfaction after Total Knee Arthroplasty: Who is Satisfied and Who is Not?Clinical Orthopaedics and Related Research, 2010
- Concentration‐ and composition‐dependent effects of metal ions on human MG‐63 osteoblastsJournal of Biomedical Materials Research, 2002
- Quantitative evaluation of the prosthetic head damage induced by microscopic third‐body particles in total hip replacementJournal of Biomedical Materials Research, 2001
- Three-body abrasive wear behaviour of orthopaedic implant bearing surfaces from titanium debrisJournal of Materials Science: Materials in Medicine, 1994