Optimization-based image reconstruction from sparse-view data in offset-detector CBCT
Authors:
- 21 January 2012
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 58 (2) , 205-230
Abstract
The field of view (FOV) of a cone-beam computed tomography (CBCT) unit in a single-photon emission computed tomography (SPECT)/CBCT system can be increased by offsetting the CBCT detector. Analytic-based algorithms have been developed for image reconstruction from data collected at a large number of densely sampled views in offset-detector CBCT. However, the radiation dose involved in a large number of projections can be of a health concern to the imaged subject. CBCT-imaging dose can be reduced by lowering the number of projections. As analytic-based algorithms are unlikely to reconstruct accurate images from sparse-view data, we investigate and characterize in the work optimization-based algorithms, including an adaptive steepest descent-weighted projection onto convex sets (ASD-WPOCS) algorithms, for image reconstruction from sparse-view data collected in offset-detector CBCT. Using simulated data and real data collected from a physical pelvis phantom and patient, we verify and characterize properties of the algorithms under study. Results of our study suggest that optimization-based algorithms such as ASD-WPOCS may be developed for yielding images of potential utility from a number of projections substantially smaller than those used currently in clinical SPECT/CBCT imaging, thus leading to a dose reduction in CBCT imaging.Keywords
This publication has 45 references indexed in Scilit:
- A comprehensive study on the relationship between the image quality and imaging dose in low-dose cone beam CTPhysics in Medicine & Biology, 2012
- Prior image constrained compressed sensing: Implementation and performance evaluationMedical Physics, 2011
- Evaluation of sparse-view reconstruction from flat-panel-detector cone-beam CTPhysics in Medicine & Biology, 2010
- Compressed sensing based cone‐beam computed tomography reconstruction with a first‐order methoda)Medical Physics, 2010
- Why do commercial CT scanners still employ traditional, filtered back-projection for image reconstruction?Inverse Problems, 2009
- Performance comparison between total variation (TV)-based compressed sensing and statistical iterative reconstruction algorithmsPhysics in Medicine & Biology, 2009
- Image reconstruction in circular cone-beam computed tomography by constrained, total-variation minimizationPhysics in Medicine & Biology, 2008
- Statistical inverse problems: Discretization, model reduction and inverse crimesJournal of Computational and Applied Mathematics, 2007
- Optimal short scan convolution reconstruction for fan beam CTMedical Physics, 1982
- Algebraic Reconstruction Techniques (ART) for three-dimensional electron microscopy and X-ray photographyJournal of Theoretical Biology, 1970