Compressed sensing reconstruction for high‐SNR, rapid dissolved 129Xe gas exchange MRI
Open Access
- 25 September 2024
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 93 (2) , 741-750
Abstract
Purpose: Three‐dimensional hyperpolarized 129Xe gas exchange imaging suffers from low SNR and long breath‐holds, which could be improved using compressed sensing (CS). The purpose of this work was to assess whether gas exchange ratio maps are quantitatively preserved in CS‐accelerated dissolved‐phase 129Xe imaging and to investigate the feasibility of CS‐dissolved 129Xe imaging with reduced‐cost natural abundance (NA) xenon.Methods: 129Xe gas exchange imaging was performed at 1.5 T with a multi‐echo spectroscopic imaging sequence. A CS reconstruction with an acceleration factor of 2 was compared retrospectively with conventional gridding reconstruction in a cohort of 16 healthy volunteers, 5 chronic obstructive pulmonary disease patients, and 23 patients who were hospitalized following COVID‐19 infection. Metrics of comparison included normalized mean absolute error, mean gas exchange ratio, and red blood cell (RBC) image SNR. Dissolved 129Xe CS imaging with NA xenon was assessed in 4 healthy volunteers.Results: CS reconstruction enabled acquisition time to be halved, and it reduced background noise. Median RBC SNR increased from 6 (2–18) to 11 (2–100) with CS, and there was strong agreement between CS and gridding mean ratio map values (R2 = 0.99). Image fidelity was maintained for gridding RBC SNR > 5, but below this, normalized mean absolute error increased nonlinearly with decreasing SNR. CS increased the mean SNR of NA 129Xe images 3‐fold.Conclusion: CS reconstruction of dissolved 129Xe imaging improved image quality with decreased scan time, while preserving key gas exchange metrics. This will benefit patients with breathlessness and/or low gas transfer and shows promise for NA‐dissolved 129Xe imaging.Keywords
Funding Information
- Medical Research Council (MR/M008894/1)
- Engineering and Physical Sciences Research Council (EP/X025187/1)
This publication has 31 references indexed in Scilit:
- Assessment of pulmonary morphometry using hyperpolarized 129Xe diffusion‐weighted MRI with variable‐sampling‐ratio compressed sensing patternsMedical Physics, 2022
- Repeatability of regional pulmonary functional metrics of Hyperpolarized 129Xe dissolved‐phase MRIJournal of Magnetic Resonance Imaging, 2019
- 3D diffusion‐weighted 129Xe MRI for whole lung morphometryMagnetic Resonance in Medicine, 2017
- Whole lung morphometry with 3D multiple b‐value hyperpolarized gas MRI and compressed sensingMagnetic Resonance in Medicine, 2016
- Single‐breath clinical imaging of hyperpolarized 129xe in the airspaces, barrier, and red blood cells using an interleaved 3D radial 1‐point Dixon acquisitionMagnetic Resonance in Medicine, 2015
- Feasibility of human lung ventilation imaging using highly polarized naturally abundant xenon and optimized three‐dimensional steady‐state free precessionMagnetic Resonance in Medicine, 2015
- Experimental validation of the hyperpolarized 129Xe chemical shift saturation recovery technique in healthy volunteers and subjects with interstitial lung diseaseMagnetic Resonance in Medicine, 2014
- Regional mapping of gas uptake by blood and tissue in the human lung using hyperpolarized xenon‐129 MRIJournal of Magnetic Resonance Imaging, 2013
- IDEAL spiral CSI for dynamic metabolic MR imaging of hyperpolarized [1‐13C]pyruvateMagnetic Resonance in Medicine, 2011
- Sparse MRI: The application of compressed sensing for rapid MR imagingMagnetic Resonance in Medicine, 2007