Rapid determination of plutonium in urine using flow injection on-line preconcentration and inductively coupled plasma mass spectrometry
- 1 April 2005
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 20 (5) , 424-430
Abstract
A rapid technique for the determination of Pu in urine samples using flow injection (FI) on-line preconcentration, desolvation nebulization using a highly sensitive APEX device and inductively coupled plasma mass spectrometry with a dynamic reaction cell (ICP-DRC-MS) was developed. Using the DRC avoided the necessity to separate Pu from U, and thus made the technique more rapid. Effective preconcentration and matrix separation for urine samples was achieved using TRU resin as the ion exchanger. A detection limit for 242Pu of 1.9 pg L−1 was achieved for raw, undigested urine samples using a 10 ml sample volume. The reproducibility of the method was demonstrated by recovery measurements performed on urine that had been collected from several non-exposed volunteers and spiked with Pu. 205Tl and 175Lu were used as an internal standard and yield tracer, respectively. The method provides a rapid (∼11 min) means of measuring Pu in urine with no off-line sample pre-treatment, at levels below the regulatory requirements for drinking water.Keywords
This publication has 17 references indexed in Scilit:
- Application of isotope-dilution laser ablation ICP?MS for direct determination of Pu concentrations in soils at pg g?1 levelsAnalytical and Bioanalytical Chemistry, 2004
- Separation of plutonium from soil and sediment prior to determination by inductively coupled plasma mass spectrometryJournal of Analytical Atomic Spectrometry, 2003
- Determination of Plutonium in Soil by ICP‐MS After CCC PreseparationJournal of Liquid Chromatography & Related Technologies, 2003
- Rapid analysis for plutonium-239 in urine by magnetic sector inductively coupled plasma-mass spectrometry using Aridus desolvation introduction systemJournal of Analytical Atomic Spectrometry, 2003
- Determination of Pu concentration and its isotope ratio in Japanese soils by HR-ICP-MSJournal of Radioanalytical and Nuclear Chemistry, 2003
- A rapid and accurate method for the determination of plutonium in food using magnetic sector ICP-MS with an ultra-sonic nebuliser and ion chromatography© Copyright LGC Limited 2003.Journal of Environmental Monitoring, 2003
- Determination of Pu Isotopes in Seawater by an On-Line Sequential Injection Technique with Sector Field Inductively Coupled Plasma Mass SpectrometryAnalytical Chemistry, 2002
- Rapid Separation of Plutonium in Environmental Samples Using an Anion Exchange Resin DiskJournal of Radioanalytical and Nuclear Chemistry, 2001
- Determination of plutonium concentration and its isotopic ratio in environmental materials by ICP-MS after separation using and extraction chromatographyJournal of Analytical Atomic Spectrometry, 1999
- Determination of plutonium in seawater using co-precipitation and inductively coupled plasma mass spectrometry with ultrasonic nebulisationSpectrochimica Acta Part B: Atomic Spectroscopy, 1998