Vladimir N. Epov
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Vladimir N. Epov has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
R. Douglas Evans
Environmental and Resource Studies, Trent University, Peterborough, ON, Canada
3 shared publicationsKarima Benkhedda
Environmental and Resource Studies, Trent University, Peterborough, ON, Canada
2 shared publicationsD. Lariviere
Trent University
1 shared publicationDominic Lariviere
Trent University, 1600 West Bank Drive, Peterborough, Ontario, Canada K9J 7B8
1 shared publicationEkaterina N. Epova
Trent University, 1600 West Bank Drive, Peterborough, Ontario, Canada K9J 7B8
1 shared publicationR. D. Evans
Trent University
1 shared publication
Latest Publications
- 23 May 2005
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 20 (9) , 990-992
Determination of Pu isotopes in vegetation using a new on-line FI-ICP-DRC-MS protocol after microwave digestion
A new protocol for the determination of Pu isotopes in leaves has been developed. The method consists of microwave sample digestion, flow injection on-line preconcentration/matrix separation, sample desolvation and introduction using an APEX unit and elemental determination using ICP-MS with a dynamic reaction cell. The preconcentration and matrix separation was performed using an anion-exchange resin (AG MP-1M). Detection limits as low as 2.9 fg g−1 and 0.46 fg g−1 were obtained for 239Pu and other Pu isotopes (240Pu, 241Pu, 242Pu and 244Pu), respectively, for 10 g of NIST-SRM 1515, Apple Leaves. The yield recovery of Pu was also determined for different leaf samples collected locally and spiked with a known concentration of 239Pu and 242Pu.
- 23 May 2005
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 20 (9) , 990-992
Determination of Pu isotopes in vegetation using a new on-line FI-ICP-DRC-MS protocol after microwave digestion
A new protocol for the determination of Pu isotopes in leaves has been developed. The method consists of microwave sample digestion, flow injection on-line preconcentration/matrix separation, sample desolvation and introduction using an APEX unit and elemental determination using ICP-MS with a dynamic reaction cell. The preconcentration and matrix separation was performed using an anion-exchange resin (AG MP-1M). Detection limits as low as 2.9 fg g−1 and 0.46 fg g−1 were obtained for 239Pu and other Pu isotopes (240Pu, 241Pu, 242Pu and 244Pu), respectively, for 10 g of NIST-SRM 1515, Apple Leaves. The yield recovery of Pu was also determined for different leaf samples collected locally and spiked with a known concentration of 239Pu and 242Pu.
- 1 April 2005
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 20 (5) , 424-430
Rapid determination of plutonium in urine using flow injection on-line preconcentration and inductively coupled plasma mass spectrometry
A rapid technique for the determination of Pu in urine samples using flow injection (FI) on-line preconcentration, desolvation nebulization using a highly sensitive APEX device and inductively coupled plasma mass spectrometry with a dynamic reaction cell (ICP-DRC-MS) was developed. Using the DRC avoided the necessity to separate Pu from U, and thus made the technique more rapid. Effective preconcentration and matrix separation for urine samples was achieved using TRU resin as the ion exchanger. A detection limit for 242Pu of 1.9 pg L−1 was achieved for raw, undigested urine samples using a 10 ml sample volume. The reproducibility of the method was demonstrated by recovery measurements performed on urine that had been collected from several non-exposed volunteers and spiked with Pu. 205Tl and 175Lu were used as an internal standard and yield tracer, respectively. The method provides a rapid (∼11 min) means of measuring Pu in urine with no off-line sample pre-treatment, at levels below the regulatory requirements for drinking water.
- 1 April 2005
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 20 (5) , 424-430
Rapid determination of plutonium in urine using flow injection on-line preconcentration and inductively coupled plasma mass spectrometry
A rapid technique for the determination of Pu in urine samples using flow injection (FI) on-line preconcentration, desolvation nebulization using a highly sensitive APEX device and inductively coupled plasma mass spectrometry with a dynamic reaction cell (ICP-DRC-MS) was developed. Using the DRC avoided the necessity to separate Pu from U, and thus made the technique more rapid. Effective preconcentration and matrix separation for urine samples was achieved using TRU resin as the ion exchanger. A detection limit for 242Pu of 1.9 pg L−1 was achieved for raw, undigested urine samples using a 10 ml sample volume. The reproducibility of the method was demonstrated by recovery measurements performed on urine that had been collected from several non-exposed volunteers and spiked with Pu. 205Tl and 175Lu were used as an internal standard and yield tracer, respectively. The method provides a rapid (∼11 min) means of measuring Pu in urine with no off-line sample pre-treatment, at levels below the regulatory requirements for drinking water.
- 1 July 2004
- Published by Wiley in Geostandards and Geoanalytical Research
- Vol. 28 (2) , 213-224
Polyatomic Interferences Produced by Macroelements During Direct Multi‐Elemental ICP‐MS Hydrochemical Analysis
An experimental study of the interferences produced by macroelements (Na, K, Ca, Mg, Sr, S, Cl, Si, N and C) contained in natural waters during inductively coupled plasma‐mass spectrometry (ICP‐MS) is presented. The most significant interferences created by these elements were found to be SO, CO, CAr, SiH, SiO, NaH, NaAr, MgAr, CaO, KO and KAr, the magnitude of which was dependant on the concentration of each macroelement. To reduce these interferences, different approaches, for example, desolvating nebulisation, high resolution and dynamic reaction cell ICP‐MS were applied and compared. All three approaches were found to be useful tools for significantly reducing various polyatomic interferences. Advantages and disadvantages for each approach are discussed.
- 1 July 2004
- Published by Wiley in Geostandards and Geoanalytical Research
- Vol. 28 (2) , 213-224
Polyatomic Interferences Produced by Macroelements During Direct Multi‐Elemental ICP‐MS Hydrochemical Analysis
An experimental study of the interferences produced by macroelements (Na, K, Ca, Mg, Sr, S, Cl, Si, N and C) contained in natural waters during inductively coupled plasma‐mass spectrometry (ICP‐MS) is presented. The most significant interferences created by these elements were found to be SO, CO, CAr, SiH, SiO, NaH, NaAr, MgAr, CaO, KO and KAr, the magnitude of which was dependant on the concentration of each macroelement. To reduce these interferences, different approaches, for example, desolvating nebulisation, high resolution and dynamic reaction cell ICP‐MS were applied and compared. All three approaches were found to be useful tools for significantly reducing various polyatomic interferences. Advantages and disadvantages for each approach are discussed.
- 1 December 2003
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 258 (3) , 473-480
Collision cell chemistry for the analysis of radioisotopes by inductively coupled plasma mass spectrometry
- 1 December 2003
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 258 (3) , 473-480
Collision cell chemistry for the analysis of radioisotopes by inductively coupled plasma mass spectrometry