Design and Application of a Wearable OPM-MMG System via Motion Artifacts Suppression
- 16 June 2025
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (15) , 29446-29453
Abstract
The magnetomyography system utilizing optically pumped magnetometer (OPM-MMG) is applicable for electrophysiological study of brachial plexus. In this paper, the suppression method of motion artifacts is proposed by optimal design of magnetic shielding barrel and the gradient measurement of arrayed OPMs. Firstly, multi-parameter optimization design of magnetic shield barrel is carried out. The purpose of design is to meet the requirements of residual magnetic field and magnetic noise of OPM-MMG system by optimizing several parameters of magnetic shield barrel. The experimental results show that the center residual field of the magnetic shield barrel is 8.64nT±0.5nT, and the magnetic noise is lower than 10fT/Hz1/2, which can provide excellent near-zero magnetic environment for MMG experiment. Furthermore, the gradiometer mode is used to measure the magnetic field of muscle for suppressing the motion artifacts. Experimental results show that the SNR of extensor digitorum muscle’s signal is increased from 12.1dB to 47.8dB compared with magnetometer mode. Consequently, the enhanced OPM-MMG system is capable of producing clearer MMG images.Keywords
Funding Information
- National Natural Science Foundation of China (62403102)
This publication has 24 references indexed in Scilit:
- Research on the anti-interference ability of optically pumped magnetometerMeasurement, 2023
- Real-time, model-based magnetic field correction for moving, wearable MEGNeuroImage, 2023
- MMG Signal Analysis for Muscle Performance AssessmentProcedia Computer Science, 2023
- Cross-Axis Dynamic Field Compensation of Optically Pumped Magnetometer Arrays for MEGNeuroImage, 2022
- Interference suppression techniques for OPM-based MEG: Opportunities and challengesNeuroImage, 2022
- Cross-Axis projection error in optically pumped magnetometers and its implication for magnetoencephalography systemsNeuroImage, 2021
- Optically pumped magnetometers reveal fasciculations non-invasivelyClinical Neurophysiology, 2021
- Investigation of the temporal and spatial dynamics of muscular action potentials through optically pumped magnetometersJournal of Electromyography and Kinesiology, 2021
- Optically pumped magnetometers disclose magnetic field components of the muscular action potentialJournal of Electromyography and Kinesiology, 2021
- Surface Electromyography (EMG) Signal Processing, Classification, and Practical Considerations2019