Ziyuan Huang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Ziyuan Huang has a total of 55 co-authors. Here are the top co-authors by number of shared publications:
- Zhongya Ding
School of Optelectronics Engineering and Instrument Science, Dalian University of Technology, Dalian, China
11 shared publications - Bangcheng Han
School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing 100191, China
10 shared publications - Maotong Pang
Hangzhou Institute of Extremely-Weak Magnetic Field Major National Science and Technology Infrastructure, Hangzhou, China
9 shared publications - Haitao Niu
Beihang University
3 shared publications Bangcheng Han
School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing, China
2 shared publications- Baodong Chen
School of Instrumentation and Optoelectronic Engineering, Ministry of Education, Fundamental Science on Novel Inertial Instrument and Navigation System Technology Laboratory, Beihang University, Beijing, China
2 shared publications
Latest Publications
- 1 October 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 45 (10) , 4937-4953
Topology Optimization of Magnetocardiographic Array Based on Cardiac Electromagnetic Simulation Model
Array topology in magnetocardiography system dictates spatial resolution and clinical applicability, impacting topographic reconstruction, which affects the accuracy of feature and source localization. Existing array designs rely on task-driven or empirical criteria without accounting for intrinsic imaging properties to ensure complete high-precision reconstruction and broad applicability, and analyses regarding the impact of array parameters on imaging remain lacking. To address these limitations, a computationally efficient electromagnetic simulation framework is proposed to guide array topological optimization. A three-dimensional electrophysiological forward model, combining the monodomain equation with phenomenological formulation, is constructed and regional parameters are optimized to rapidly simulate transmembrane potential. Following rigorousmultidimensional validation of the mapped magnetic distribution against real data, high-fidelity signals are utilized to demonstrate the necessity of parameter optimization for imaging and to establish universally applicable criteria for the effective coverage to completely capture signals. The Manifold Harmonic Transform and the sampling theorem are employed to analyze dynamic anti-aliasing sampling requirements across cardiac cycle. Ultimately, integrating the spatial coverage and sampling criteria with a highly efficient hexagonal layout yields a broadly applicable and cost-effective topology. The reliability of array is verified and results demonstrate that the optimized configuration can achieve complete and robust reconstruction of spatiotemporally evolving signals, thereby establishing a quantitative foundation and reliable paradigm for the clinical deployment and application of system. Meanwhile, the analysis process of array optimization can serve as a reference for other application scenarios.
- 1 October 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 45 (10) , 4937-4953
Topology Optimization of Magnetocardiographic Array Based on Cardiac Electromagnetic Simulation Model
Array topology in magnetocardiography system dictates spatial resolution and clinical applicability, impacting topographic reconstruction, which affects the accuracy of feature and source localization. Existing array designs rely on task-driven or empirical criteria without accounting for intrinsic imaging properties to ensure complete high-precision reconstruction and broad applicability, and analyses regarding the impact of array parameters on imaging remain lacking. To address these limitations, a computationally efficient electromagnetic simulation framework is proposed to guide array topological optimization. A three-dimensional electrophysiological forward model, combining the monodomain equation with phenomenological formulation, is constructed and regional parameters are optimized to rapidly simulate transmembrane potential. Following rigorousmultidimensional validation of the mapped magnetic distribution against real data, high-fidelity signals are utilized to demonstrate the necessity of parameter optimization for imaging and to establish universally applicable criteria for the effective coverage to completely capture signals. The Manifold Harmonic Transform and the sampling theorem are employed to analyze dynamic anti-aliasing sampling requirements across cardiac cycle. Ultimately, integrating the spatial coverage and sampling criteria with a highly efficient hexagonal layout yields a broadly applicable and cost-effective topology. The reliability of array is verified and results demonstrate that the optimized configuration can achieve complete and robust reconstruction of spatiotemporally evolving signals, thereby establishing a quantitative foundation and reliable paradigm for the clinical deployment and application of system. Meanwhile, the analysis process of array optimization can serve as a reference for other application scenarios.
- 1 September 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (17) , 25572-25581
Design of Highly Uniform Cylindrical Coils Based on an Improved Sand Cat Swarm Optimization Algorithm for Small-Animal Magnetocardiography
- 1 September 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (17) , 25572-25581
Design of Highly Uniform Cylindrical Coils Based on an Improved Sand Cat Swarm Optimization Algorithm for Small-Animal Magnetocardiography
- 16 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (15) , 29446-29453
Design and Application of a Wearable OPM-MMG System via Motion Artifacts Suppression
The magnetomyography system utilizing optically pumped magnetometer (OPM-MMG) is applicable for electrophysiological study of brachial plexus. In this paper, the suppression method of motion artifacts is proposed by optimal design of magnetic shielding barrel and the gradient measurement of arrayed OPMs. Firstly, multi-parameter optimization design of magnetic shield barrel is carried out. The purpose of design is to meet the requirements of residual magnetic field and magnetic noise of OPM-MMG system by optimizing several parameters of magnetic shield barrel. The experimental results show that the center residual field of the magnetic shield barrel is 8.64nT±0.5nT, and the magnetic noise is lower than 10fT/Hz1/2, which can provide excellent near-zero magnetic environment for MMG experiment. Furthermore, the gradiometer mode is used to measure the magnetic field of muscle for suppressing the motion artifacts. Experimental results show that the SNR of extensor digitorum muscle’s signal is increased from 12.1dB to 47.8dB compared with magnetometer mode. Consequently, the enhanced OPM-MMG system is capable of producing clearer MMG images.
- 16 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (15) , 29446-29453
Design and Application of a Wearable OPM-MMG System via Motion Artifacts Suppression
The magnetomyography system utilizing optically pumped magnetometer (OPM-MMG) is applicable for electrophysiological study of brachial plexus. In this paper, the suppression method of motion artifacts is proposed by optimal design of magnetic shielding barrel and the gradient measurement of arrayed OPMs. Firstly, multi-parameter optimization design of magnetic shield barrel is carried out. The purpose of design is to meet the requirements of residual magnetic field and magnetic noise of OPM-MMG system by optimizing several parameters of magnetic shield barrel. The experimental results show that the center residual field of the magnetic shield barrel is 8.64nT±0.5nT, and the magnetic noise is lower than 10fT/Hz1/2, which can provide excellent near-zero magnetic environment for MMG experiment. Furthermore, the gradiometer mode is used to measure the magnetic field of muscle for suppressing the motion artifacts. Experimental results show that the SNR of extensor digitorum muscle’s signal is increased from 12.1dB to 47.8dB compared with magnetometer mode. Consequently, the enhanced OPM-MMG system is capable of producing clearer MMG images.
- 8 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-12
Sampling and Layout of OPM Arrays for MCG Based on the Sampling Theorem
Given that the sampling and arrangement of the array need a reasonable standard to guide in high-precision magnetocardiography (MCG) imaging, the sampling range required for robust topography reconstruction is determined analytically by utilizing the frequency-domain analysis method according to the spatial Nyquist sampling theorem, and the layout with the highest sampling efficiency in uniform arrangement is found based on multidimensional sampling theorem. The results show that the upper limit of sampling distance required to reliably reconstruct the normal component is 0.71 times linearly related to the distance between the detection plane and source, and the minimum sampling period is also quantitatively associated with the distance and the noise level. When sampling the 2-D signal with the isotropic spectrum, among all uniform layouts without aliasing, the hexagonal lattice exhibits the highest sampling efficiency, surpassing that of the conventional rectangular lattice by approximately 12.15%. Finally, the necessity of sampling range and the effectiveness of hexagonal lattice are verified through simulation and experiment. This article provides the constraint and reference for the design of MCG array and the selection of sensor in various scenarios, while also indicating the sensor direction for further development.
- 8 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-12
Sampling and Layout of OPM Arrays for MCG Based on the Sampling Theorem
Given that the sampling and arrangement of the array need a reasonable standard to guide in high-precision magnetocardiography (MCG) imaging, the sampling range required for robust topography reconstruction is determined analytically by utilizing the frequency-domain analysis method according to the spatial Nyquist sampling theorem, and the layout with the highest sampling efficiency in uniform arrangement is found based on multidimensional sampling theorem. The results show that the upper limit of sampling distance required to reliably reconstruct the normal component is 0.71 times linearly related to the distance between the detection plane and source, and the minimum sampling period is also quantitatively associated with the distance and the noise level. When sampling the 2-D signal with the isotropic spectrum, among all uniform layouts without aliasing, the hexagonal lattice exhibits the highest sampling efficiency, surpassing that of the conventional rectangular lattice by approximately 12.15%. Finally, the necessity of sampling range and the effectiveness of hexagonal lattice are verified through simulation and experiment. This article provides the constraint and reference for the design of MCG array and the selection of sensor in various scenarios, while also indicating the sensor direction for further development.
- 31 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (6) , 10186-10195
Decoupling Design Model of Square Uniform-Field Coil System Using Improved PSO-ANN Algorithm
In this paper, a decoupling coil design method is proposed to solve the coupling problem of square uniform field coil design for magnetic field control system in cell culture device. Firstly, particle swarm optimization algorithm is improved by adaptive weights and penalty functions. Secondly, the artificial neural network is used to construct coil design models with magnetic shielding layers combined with improved particle swarm optimization algorithm. The simulation result shows that the maximum errors of coil design model is less than 0.8%. Then, the design model was used to design the uniform-field coil system in the magnetic control system of cell culture system. The simulation results show that the maximum normalized error of coil system in the target region is 0.966%, which is 2.3 times and 2.4 times less than standard square Helmholtz coil system (2.24%) and bi-planar coil system (2.32%) under same size. The experimental result of magnetic field control system shows that the uniform-field coil system can produce 1 μT with 1.7 nT mean error, which is 3.6 times less than the square Helmholtz coil system (6.1 nT average error).
- 31 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (6) , 10186-10195
Decoupling Design Model of Square Uniform-Field Coil System Using Improved PSO-ANN Algorithm
In this paper, a decoupling coil design method is proposed to solve the coupling problem of square uniform field coil design for magnetic field control system in cell culture device. Firstly, particle swarm optimization algorithm is improved by adaptive weights and penalty functions. Secondly, the artificial neural network is used to construct coil design models with magnetic shielding layers combined with improved particle swarm optimization algorithm. The simulation result shows that the maximum errors of coil design model is less than 0.8%. Then, the design model was used to design the uniform-field coil system in the magnetic control system of cell culture system. The simulation results show that the maximum normalized error of coil system in the target region is 0.966%, which is 2.3 times and 2.4 times less than standard square Helmholtz coil system (2.24%) and bi-planar coil system (2.32%) under same size. The experimental result of magnetic field control system shows that the uniform-field coil system can produce 1 μT with 1.7 nT mean error, which is 3.6 times less than the square Helmholtz coil system (6.1 nT average error).
- 5 January 2025
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 383
Optimization design of different induction magnetometers for MCG
- 5 January 2025
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 383
Optimization design of different induction magnetometers for MCG
- 16 April 2024
- Published by Elsevier in Measurement
- Vol. 234
Optimized design of uniform-field coils system with a large uniform region by particle swarm optimization algorithm
- 16 April 2024
- Published by Elsevier in Measurement
- Vol. 234
Optimized design of uniform-field coils system with a large uniform region by particle swarm optimization algorithm
- 4 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Informatics
- Vol. 20 (4) , 6289-6299
Harmonic Suppression for PMSM Applied to MSTMP Based on Virtual Even-Order Fractional Repetitive Controller
Current harmonics will produce losses, which make motor heated. The high temperature of the motor applied to turbo molecular pump (TMP) will degrade ultrahigh vacuum performance severely. Current harmonics should be suppressed effectively. The repetitive controller (RC) has been widely used in harmonic suppression. To address key challenges of conventional RC, this article proposes a novel virtual even-order fractional RC. First, the virtual fundamental frequency is introduced and the even-order RC is constructed. Second, the Lagrange interpolation is designed to fit the fractional part of the delay coefficient. Then, the low-pass filter (LPF) is replaced by a finite impulse response (FIR) filter and is removed out of RC internal model. The proposed method can improve the convergence speed of harmonic suppression. The tracking deviation in the high-frequency band is reduced and the harmonic suppression accuracy is improved. Finally, the effectiveness of the method is verified on the high-speed magnetically suspended TMP.
- 4 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Informatics
- Vol. 20 (4) , 6289-6299
Harmonic Suppression for PMSM Applied to MSTMP Based on Virtual Even-Order Fractional Repetitive Controller
Current harmonics will produce losses, which make motor heated. The high temperature of the motor applied to turbo molecular pump (TMP) will degrade ultrahigh vacuum performance severely. Current harmonics should be suppressed effectively. The repetitive controller (RC) has been widely used in harmonic suppression. To address key challenges of conventional RC, this article proposes a novel virtual even-order fractional RC. First, the virtual fundamental frequency is introduced and the even-order RC is constructed. Second, the Lagrange interpolation is designed to fit the fractional part of the delay coefficient. Then, the low-pass filter (LPF) is replaced by a finite impulse response (FIR) filter and is removed out of RC internal model. The proposed method can improve the convergence speed of harmonic suppression. The tracking deviation in the high-frequency band is reduced and the harmonic suppression accuracy is improved. Finally, the effectiveness of the method is verified on the high-speed magnetically suspended TMP.
- 19 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-10
Automatic Sensor Array Calibration and Coregistration for On-Scalp MEG
Accurate MEG localization of neural electrical activity requires registration between the MEG sensors and MRI. To reduce the geometric error of the sensor array and realize automatic registration, an array geometry calibration algorithm based on prior knowledge is proposed, which automatically completes the position and orientation calibration of OPM-MEG array with the reference of the design model of MEG helmet. Full-process automatic co-registration based on optical scanning is realized. A position error of 0.23 ± 0.12mm and orientation error of 0.34 ± 0.14° are obtained in the calibration results of 85 sensors on-scalp MEG system. The proposed array geometric calibration algorithm is used to quantify the deviation between the manufactured array and the theoretical array for the first time. The results show a mean position deviation of 0.57mm and an angle deviation of 0.68° in the manufactured array, with the maximum position deviation of 1.45 mm and the maximum orientation deviation of 2.13°. It is indicated that the replacement of the manufactured array by the theoretical array in previous research may introduce significant errors in the MEG source localization results.
- 19 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-10
Automatic Sensor Array Calibration and Coregistration for On-Scalp MEG
Accurate MEG localization of neural electrical activity requires registration between the MEG sensors and MRI. To reduce the geometric error of the sensor array and realize automatic registration, an array geometry calibration algorithm based on prior knowledge is proposed, which automatically completes the position and orientation calibration of OPM-MEG array with the reference of the design model of MEG helmet. Full-process automatic co-registration based on optical scanning is realized. A position error of 0.23 ± 0.12mm and orientation error of 0.34 ± 0.14° are obtained in the calibration results of 85 sensors on-scalp MEG system. The proposed array geometric calibration algorithm is used to quantify the deviation between the manufactured array and the theoretical array for the first time. The results show a mean position deviation of 0.57mm and an angle deviation of 0.68° in the manufactured array, with the maximum position deviation of 1.45 mm and the maximum orientation deviation of 2.13°. It is indicated that the replacement of the manufactured array by the theoretical array in previous research may introduce significant errors in the MEG source localization results.