An Algorithm for Heart Rate Extraction From Acoustic Recordings at the Neck
Open Access
- 18 May 2018
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 66 (1) , 246-256
Abstract
Heart rate is an important physiological parameter to assess the cardiac condition of an individual and is traditionally determined by attaching multiple electrodes on the chest of a subject to record the electrical activity of the heart. The installation and handling complexities of such systems does not prove feasible for a user to undergo a long-term monitoring in the home settings. A small-sized, battery-operated wearable monitoring device is placed on the suprasternal notch at neck to record acoustic signals containing information about breathing and cardiac sounds. The heart sounds obtained are heavily corrupted by the respiratory cycles and other external artifacts. This paper presents a novel algorithm for reliably extracting the heart rate from such acoustic recordings, keeping in mind the constraints posed by the wearable technology. The methodology constructs the Hilbert energy envelope of the signal by calculating its instantaneous characteristics to segment and classify a cardiac cycle into S1 and S2 sounds using their timing characteristics. The algorithm is tested on a dataset consisting of 13 subjects with an approximate data length of 75 hours and achieves an accuracy of 94.34%, an RMS error of 3.96 bpm and a correlation coefficient of 0.93 with reference to a commercial device in use.Keywords
Funding Information
- H2020 European Research Council (Grant Agreement N 724334)
This publication has 28 references indexed in Scilit:
- An automated tool for localization of heart sound components S1, S2, S3 and S4 in pulmonary sounds using Hilbert transform and Heron’s formulaSpringerPlus, 2013
- A comparison of photoplethysmography and ECG recording to analyse heart rate variability in healthy subjectsJournal of Medical Engineering & Technology, 2009
- A robust heart sound segmentation algorithm for commonly occurring heart valve diseasesJournal of Medical Engineering & Technology, 2008
- Neural network classification of homomorphic segmented heart soundsApplied Soft Computing, 2007
- Brachial–ankle pulse wave velocity: an index of central arterial stiffness?Journal of Human Hypertension, 2005
- Heart rate and the cardiovascular riskJournal Of Hypertension, 1997
- Computing the Hilbert transform on the real lineMathematics of Computation, 1995
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Spectral analysis of heart sounds: Relationships between some physical characteristics and frequency spectra of first and second heart sounds in normals and hypertensivesJournal of Biomedical Engineering, 1984
- Systolic Time Intervals in Heart Failure in ManCirculation, 1968