Clinical implementation of full Monte Carlo dose calculation in proton beam therapy
Authors:
- Honggu JiangHJHonggu Jiang
- Katia ParodiKPKatia Parodi
- Roelf SlopsemaRSRoelf Slopsema
- Martijn EngelsmanMEMartijn Engelsman
- 13 August 2008
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 53 (17) , 4825-4853
Abstract
The goal of this work was to facilitate the clinical use of Monte Carlo proton dose calculation to support routine treatment planning and delivery. The Monte Carlo code Geant4 was used to simulate the treatment head setup, including a time-dependent simulation of modulator wheels (for broad beam modulation) and magnetic field settings (for beam scanning). Any patient-field-specific setup can be modeled according to the treatment control system of the facility. The code was benchmarked against phantom measurements. Using a simulation of the ionization chamber reading in the treatment head allows the Monte Carlo dose to be specified in absolute units (Gy per ionization chamber reading). Next, the capability of reading CT data information was implemented into the Monte Carlo code to model patient anatomy. To allow time-efficient dose calculation, the standard Geant4 tracking algorithm was modified. Finally, a software link of the Monte Carlo dose engine to the patient database and the commercial planning system was established to allow data exchange, thus completing the implementation of the proton Monte Carlo dose calculation engine ('DoC++'). Monte Carlo re-calculated plans are a valuable tool to revisit decisions in the planning process. Identification of clinically significant differences between Monte Carlo and pencil-beam-based dose calculations may also drive improvements of current pencil-beam methods. As an example, four patients (29 fields in total) with tumors in the head and neck regions were analyzed. Differences between the pencil-beam algorithm and Monte Carlo were identified in particular near the end of range, both due to dose degradation and overall differences in range prediction due to bony anatomy in the beam path. Further, the Monte Carlo reports dose-to-tissue as compared to dose-to-water by the planning system. Our implementation is tailored to a specific Monte Carlo code and the treatment planning system XiO (Computerized Medical Systems Inc.). However, this work describes the general challenges and considerations when implementing proton Monte Carlo dose calculation in a clinical environment. The presented solutions can be easily adopted for other planning systems or other Monte Carlo codes.Keywords
This publication has 54 references indexed in Scilit:
- Validation ofGEANT4, an object-oriented Monte Carlo toolkit, for simulations in medical physicsMedical Physics, 2004
- Treatment Planning for Conformal Proton Radiation TherapyTechnology in Cancer Research & Treatment, 2003
- Geant4—a simulation toolkitNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2003
- Monte Carlo simulation of a dynamic MLC based on a multiple source modelPhysics in Medicine & Biology, 2001
- Description and dosimetric verification of the PEREGRINE Monte Carlo dose calculation system for photon beams incident on a water phantomMedical Physics, 2001
- A multiple source model for 6 MV photon beam dose calculations using Monte CarloPhysics in Medicine & Biology, 2001
- Simple beam models for Monte Carlo photon beam dose calculations in radiotherapyMedical Physics, 2000
- Fast Monte Carlo dose calculation for photon beams based on the VMC electron algorithmMedical Physics, 1999
- Monte Carlo and analytical calculation of proton pencil beams for computerized treatment plan optimizationPhysics in Medicine & Biology, 1997
- A pencil beam algorithm for proton dose calculationsPhysics in Medicine & Biology, 1996