A Simplified Thermal Comfort Calculation Method of Radiant Floor Cooling Technology for Office Buildings in Northern China
Open Access
Abstract
The increasing application of floor heating technology promotes the development of floor radiant cooling technology (abbreviated as FRC technology). Many office buildings in northern China try to use FRC technology to cool in summer, but thermal comfort is the key problem restricting the promotion of this technology. The thermal comfort problems of an office room with floor radiant cooling were studied in this paper by the methods of numerical simulation, control variable, and data fitting, and the experimental results were verified in multiple ways. It was found that, for an office room using floor radiant cooling, the effect of the floor surface temperature on thermal comfort was about 16%, while the effect of indoor air temperature was about 84%, and relative humidity had little effect on thermal comfort. A simplified thermal comfort calculation model was proposed, which could be used as an indicator to adjust the floor surface and indoor air temperature, or could be used to calculate the PMV-PPD value. The findings have guiding significance for the design and control of FRC technology.Keywords
Funding Information
- the Plan of Guidance and Cultivation for Young Innovative Talents of Shandong Provincial Colleges and Universities (no fund number)
This publication has 47 references indexed in Scilit:
- Analysis of the accuracy on PMV – PPD model using the ASHRAE Global Thermal Comfort Database IIBuilding and Environment, 2019
- Numerical investigation of general and local thermal comfort of an office equipped with radiant panelsIndoor and Built Environment, 2018
- Evaluation of a cloud cover based model for estimation of hourly global solar radiation in Western CanadaInternational Journal of Sustainable Energy, 2018
- Notes on the Calculation of the PMV Index by Means of AppsEnergy Procedia, 2016
- Can radiant floor heating systems be used in removable glazed enclosed patios meeting thermal comfort standards?Building and Environment, 2016
- Evaluation of thermal comfort in an historical Italian opera theatre by the calculation of the neutral comfort temperatureBuilding and Environment, 2016
- Evaluation of Indoor Thermal Environment in a Radiant-Cooled-Floor Office Building in MalaysiaApplied Mechanics and Materials, 2014
- The role of measurement accuracy on the thermal environment assessment by means of PMV indexBuilding and Environment, 2011
- Application of radiant cooling as a passive cooling option in hot humid climateBuilding and Environment, 2007
- Coefficient of determination in nonlinear signal processingSignal Processing, 2000