LZLinhua Zhang

Linhua Zhang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Linhua Zhang has a total of 45 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Heating pipeline leakage locating of pressure pulsation signal based on the integration of time–frequency characteristic extraction

    by Guorong Wang, Yongxing Song, Zhongyan Zhou, Feng Liang, Qiang Liu, Lin Liu, Linhua Zhang

    Heating pipelines play a vital role in urban infrastructure. Accurately locating pipeline leakage is essential. To address the limitations of the existing locate methods in terms of accuracy and efficiency, a new method based on the integration of time–frequency characteristic extraction (ITFE) was proposed. To study the accuracy of pipeline leakage locating in the ITFE and short-time Fourier transform (STFT) method. The experimental platform for pipeline leakage locating was established, and the pressure pulsation (PP) signal in the two leakage locations was collected. The time-domain signals are analyzed by the method of STFT and ITFE. Finally, the time difference obtained by the two methods is used for pipeline leakage location calculation. The experimental results demonstrate that the time delay differences for leak location of the PP signal using the STFT method are 0 s and 0 s, respectively. The time delay differences of the ITFE method for locating the leakage of the PP signal are 0.000 888 s and 0.000 698 s, respectively. The positioning errors are 0.049 m and 0.043 m, respectively. The relative positioning errors are 3.61% and 2.88%, respectively. The accuracy of pipeline leakage location using the ITFE method is above 96%.

  • Cavitation state recognition method of centrifugal pump based on multi-dimensional feature fusion and convolutional gate recurrent unit

    by Tonghe Zhang, Yongxing Song, Qiang Liu, Yi Ge, Linhua Zhang, Jingting Liu

    The rapid and accurate recognition of cavitation in centrifugal pumps has become essential for improving production efficiency and ensuring machinery longevity. To address the limitations of existing methods in terms of applicability, accuracy, and efficiency, a new method based on multi-dimensional feature fusion and convolutional gate recurrent unit (MCGN) was proposed. Experimental monitoring of cavitation of centrifugal pumps was conducted. Five signals at different water temperatures and operating frequencies were collected. Key modulating features were extracted by time-frequency analysis and principal component analysis. The multi-dimensional features are fused by one and two dimensional convolutional neural networks. The cavitation state label was used to label the sample set by cavitation number, net positive suction head, and cavitation evolution images captured by high-speed cameras. Finally, the neural network based on the convolutional gate recurrent unit was used to classify the cavitation state of the centrifugal pump. The experimental results demonstrate that the proposed method achieves recognition accuracies exceeding 98% for vibration signals, noise signals, outlet pressure pulsation signals, and torque signals. Compared with the short-time Fourier transform-autoencoder model, MCGN model can improve the recognition accuracy by 4.03%, computation efficiency by 20%, and loss by 87%. These advances underscore the potential of the method in monitoring and maintenance practices for centrifugal pumps.


  • Open Access

    Research on the Heating Effect of a Convection Radiator Based on a Human Thermophysiological Model

    by Zongjiang Liu, Wei Xu, Linhua Zhang, Zhong Li, Ji Li

    Forced convection is the most effective way to improve the thermal efficiency of a radiator under low-temperature conditions. This technical method differs significantly from the heating effects of general radiation and natural convection. Few studies have applied the objective evaluation method based on quantitative calculation to evaluate the effectiveness of indoor heating or optimize the technical parameters (air flow rate, air supply method, etc.) of heating systems. This article couples human metabolic factors with heating environmental factors and uses a 57-node human thermal physiological model to evaluate the effectiveness of forced convection radiator heating from the perspective of the local thermal comfort of the human body and demonstrates the feasibility of this scheme by comparing it with floor radiation heating. The research shows that the air supply speed of a radiator affects human thermal comfort. Continuing to increase the wind speed, at a speed of 3 m/s, the surface temperature of the human body reaches a high value and will then decrease, leading to a decrease in thermal comfort. Research on indoor air distribution shows that the use of bottom-side air supply provides better thermal comfort compared to top air supply. The local skin temperature distribution of the human body indicates that when the indoor average temperature is higher than 20 °C, the overall thermal comfort of convective radiator heating and floor radiant heating is comparable. The article provides a way of objectively calculating and directly quantifying the effect of heating equipment on human thermal physiological parameters.


  • Research on the characteristics of two-phase flow-induced noise in the cavitation dynamics of electronic expansion valves

    by Junyu Wang, Yongxing Song, Jingting Liu, Linhua Zhang

    Electronic expansion valves are widely used in refrigeration systems. However, the two-phase flow-induced noise is often produced during operation. In this paper, the two-phase flow-induced noise characteristics of electronic expansion valves are investigated by means of a combination of numerical calculations and experimental studies. The numerical results show that the noise distribution in the flow field is closely related to the valve opening. As the valve opening increases, the noise in the flow field begins to develop in the downstream region. The experimental results showed a gradual increase in the refrigerant flow rate of the experimental system as the valve opening was increased from 60 to 200 pulses (tested at 10-pulse intervals). The flow-induced noise increases first and then decreases and then increases. With the increase in valve opening, the cavitation phenomenon after valve throttling becomes more and more serious. By processing the noise signal, it is found that the flow-induced noise is distributed in wide frequency. When the valve opening is 60–100 pulse, the noise is mainly concentrated in 10–20 kHz. When the valve opening is 110–150 pulses, the noise concentrated in the high band gradually spreads to the low band. When the valve opening is 160–200 pulses, the noise at low frequency and high frequency increases significantly with the increase in valve opening. After adding a groove structure on the valve core, the noise of the electronic expansion valve decreased by 1.75 dB.


  • Open Access

    Research on Heating Effect of Convection Radiator Based on Human Thermophysiological Model

    by Zongjiang Liu, Wei Xu, Linhua Zhang, Zhong Li, Ji Li

    This article couples human metabolic factors and heating environmental factors, and uses a 57 node human thermal physiological model to study the heating effect of radiators. It provides a way to objectively calculate and directly quantify the effect of heating equipment on human thermal physiological parameters. As the inlet speed increases, the surface temperature of the human body first increases and then decreases. At a speed of 3m/s, it basically reaches a high value. Continuing to increase the wind speed, as the indoor convection intensity further increases, the surface temperature of the human body will decrease, leading to a decrease in thermal comfort. Compared with floor radiation heating under similar indoor temperature conditions, forced convection radiator heating has similar skin temperatures in various parts of the human body after the indoor design temperature exceeds 20 ℃, and the overall thermal comfort of the two technical solutions is equivalent. Research has shown that the turbulence wind speed of convective radiators should not be too small, with a wind speed range of 2.5m/s to 3m/s. The heating effect of using horizontal air outlet from the lower part of the radiator is better than that of vertical air outlet from the upper part. Convection type radiator heating is more suitable for buildings with rooms that are not too high due to the large indoor temperature gradient.

  • Open Access

    Estimation of Wind Speed Based on Schlieren Machine Vision System Inspired by Greenhouse Top Vent

    by Huang Li, Angui Li, Linhua Zhang, Yicun Hou, Changqing Yang, Lu Chen, Na Lu

    Greenhouse ventilation has always been an important concern for agricultural workers. This paper aims to introduce a low-cost wind speed estimating method based on SURF (Speeded Up Robust Feature) feature matching and the schlieren technique for airflow mixing with large temperature differences and density differences like conditions on the vent of the greenhouse. The fluid motion is directly described by the pixel displacement through the fluid kinematics analysis. Combining the algorithm with the corresponding image morphology analysis and SURF feature matching algorithm, the schlieren image with feature points is used to match the changes in air flow images in adjacent frames to estimate the velocity from pixel change. Through experiments, this method is suitable for the speed estimation of turbulent or disturbed fluid images. When the supply air speed remains constant, the method in this article obtains 760 sets of effective feature matching point groups from 150 frames of video, and approximately 500 sets of effective feature matching point groups are within 0.1 difference of the theoretical dimensionless speed. Under the supply conditions of high-frequency wind speed changes and compared with the digital signal of fan speed and data from wind speed sensors, the trend of wind speed changes is basically in line with the actual changes. The estimation error of wind speed is basically within 10%, except when the wind speed supply suddenly stops or the wind speed is 0 m/s. This method involves the ability to estimate the wind speed of air mixing with different densities, but further research is still needed in terms of statistical methods and experimental equipment.


  • Open Access

    A Simplified Thermal Comfort Calculation Method of Radiant Floor Cooling Technology for Office Buildings in Northern China

    by Xiaolong Wang, Tian Mu, Lili Zhang, Wenke Zhang, Linhua Zhang

    The increasing application of floor heating technology promotes the development of floor radiant cooling technology (abbreviated as FRC technology). Many office buildings in northern China try to use FRC technology to cool in summer, but thermal comfort is the key problem restricting the promotion of this technology. The thermal comfort problems of an office room with floor radiant cooling were studied in this paper by the methods of numerical simulation, control variable, and data fitting, and the experimental results were verified in multiple ways. It was found that, for an office room using floor radiant cooling, the effect of the floor surface temperature on thermal comfort was about 16%, while the effect of indoor air temperature was about 84%, and relative humidity had little effect on thermal comfort. A simplified thermal comfort calculation model was proposed, which could be used as an indicator to adjust the floor surface and indoor air temperature, or could be used to calculate the PMV-PPD value. The findings have guiding significance for the design and control of FRC technology.