Impact of the Individual Operator Experience and Learning Curve of a Novel Size Adjustable Cryoballoon
- 23 December 2024
- journal article
- research article
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 36 (2) , 422-429
Abstract
Background: Cryoballoon ablation is less operator‐dependent than radiofrequency ablation. Recently, size‐adjustable cryoballoons (SA‐CBs) have become available. We sought to analyze the individual baseline operator experience's impact on procedural results.Methods: This multicenter observational study included atrial fibrillation (AF) patients who underwent pulmonary vein (PV) isolation using SA‐CBs capable of 28‐mm or 31‐mm balloon sizes. Experienced (E‐group) or less experienced (LE‐group) operators were defined as experiencing > 100 or ≤ 100 cryoballoon procedures, respectively.Results: Among 510 patients (67 ± 11 years, 355 men, 325 paroxysmal AF [PAF]) who underwent an SA‐CB ablation, 240 and 270 were in the E‐group and LE‐group, respectively. All cryoballoon parameters were similar between the groups, except for a significantly higher 31‐mm balloon isolation rate in the E‐group than LE‐group, especially for right superior PVs. Cryoballoon‐related phrenic nerve injury occurred in 34 (6.7%) patients and tended to be higher in the LE‐group than E‐group (8.1% vs. 5.0%, p = 0.16). The AF freedom was comparable between the groups for both PAF and non‐PAF patients. A total of 36(7.1%) patients underwent re‐do procedures at 5.2 ± 2.6 months post‐index procedure. The PV reconnection rate was significantly higher in the LE‐group than E‐group (27.1% vs. 8.9%, p < 0.01), and this trend was more pronounced for right PVs than left PVs.Conclusions: In AF ablation using SA‐CBs, the overall procedural efficacy and safety were comparable between the E‐group and LE‐group. However, 100 CB procedures seemed to still be in the middle of a learning curve for selecting the balloon size and balloon position, especially for right PVs.Keywords
This publication has 12 references indexed in Scilit:
- One‐year outcomes of pulmonary vein isolation with a novel cryoballoon: Primary results of the FROZEN AF trialJournal of Cardiovascular Electrophysiology, 2024
- Feasibility and efficacy of a novel size adjustable cryoballoon for ablation of atrial fibrillationJournal of Interventional Cardiac Electrophysiology, 2023
- Novel cryoballoon ablation system for pulmonary vein isolation: multicenter assessment of efficacy and safety—ANTARCTICA studyEP Europace, 2022
- PolarX Cryoballoon metrics predicting successful pulmonary vein isolation: targets for ablation of atrial fibrillationEP Europace, 2022
- First experience of POLARx™ versus Arctic Front Advance™: An early technology comparisonJournal of Cardiovascular Electrophysiology, 2021
- Cryoballoon Ablation as Initial Therapy for Atrial FibrillationNew England Journal of Medicine, 2021
- Comparison of procedural efficacy and biophysical parameters between two competing cryoballoon technologies for pulmonary vein isolation: Insights from an initial multicenter experienceJournal of Cardiovascular Electrophysiology, 2021
- 2017 HRS/EHRA/ECAS/APHRS/SOLAECE expert consensus statement on catheter and surgical ablation of atrial fibrillationEP Europace, 2017
- Best practice guide for cryoballoon ablation in atrial fibrillation: The compilation experience of more than 3000 proceduresHeart Rhythm, 2015
- Quantitative Analysis of Isolation Area and Rhythm Outcome in Patients With Paroxysmal Atrial Fibrillation After Circumferential Pulmonary Vein Antrum Isolation Using the Pace-and-Ablate TechniqueCirculation: Arrhythmia and Electrophysiology, 2012