A convolutional neural network for estimating cone-beam CT intensity deviations from virtual CT projections
- 22 October 2021
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 66 (21) , 215007
Abstract
Extending cone-beam CT (CBCT) use toward dose accumulation and adaptive radiotherapy (ART) necessitates more accurate HU reproduction since cone-beam geometries are heavily degraded by photon scatter. This study proposes a novel method which aims to demonstrate how deep learning based on phantom data can be used effectively for CBCT intensity correction in patient images. Four anthropomorphic phantoms were scanned on a CBCT and conventional fan-beam CT system. Intensity correction is performed by estimating the cone-beam intensity deviations from prior information contained in the CT. Residual projections were extracted by subtraction of raw cone-beam projections from virtual CT projections. An improved version of U-net is utilized to train on a total of 2001 projection pairs. Once trained, the network could estimate intensity deviations from input patient head and neck raw projections. The results from our novel method showed that corrected CBCT images improved the (contrast-to-noise ratio) with respect to uncorrected reconstructions by a factor of 2.08. The mean absolute error and structural similarity index improved from 318 HU to 74 HU and 0.750 to 0.812 respectively. Visual assessment based on line-profile measurements and difference image analysis indicate the proposed method reduced noise and the presence of beam-hardening artefacts compared to uncorrected and manufacturer reconstructions. Projection domain intensity correction for cone-beam acquisitions of patients was shown to be feasible using a convolutional neural network trained on phantom data. The method shows promise for further improvements which may eventually facilitate dose monitoring and ART in the clinical radiotherapy workflow.Keywords
This publication has 35 references indexed in Scilit:
- CBCT‐based synthetic CT generation using deep‐attention cycleGAN for pancreatic adaptive radiotherapyMedical Physics, 2020
- Synthetic CT generation from CBCT images via deep learningMedical Physics, 2019
- Modified fast adaptive scatter kernel superposition (mfASKS) correction and its dosimetric impact on CBCT‐based proton therapy dose calculationMedical Physics, 2019
- Paired cycle‐GAN‐based image correction for quantitative cone‐beam computed tomographyMedical Physics, 2019
- Projection‐domain scatter correction for cone beam computed tomography using a residual convolutional neural networkMedical Physics, 2019
- Scatter correction for a clinical cone‐beam CT system using an optimized stationary beam blocker in a single scanMedical Physics, 2019
- ScatterNet: A convolutional neural network for cone‐beam CT intensity correctionMedical Physics, 2018
- U-Net: Convolutional Networks for Biomedical Image Segmentation2015
- Impact of interfractional changes in head and neck cancer patients on the delivered dose in intensity modulated radiotherapy with protons and photonsPhysica Medica, 2015
- Tumour Shrinkage and Contour Change during Radiotherapy Increase the Dose to Organs at Risk but not the Target Volumes for Head and Neck Cancer Patients Treated on the TomoTherapy HiArt™ SystemClinical Oncology, 2011