Branimir Rusanov
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Branimir Rusanov has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Martin Andrew Ebert
Department of Radiation Oncology, Sir Charles Gairdner Hospital, Nedlands, Australia
4 shared publications Mahsheed Sabet
School of Physics, Mathematics and Computing, The University of Western Australia, Crawley, Australia
3 shared publications- Pejman Rowshanfarzad
School of Physics, Mathematics and Computing, The University of Western Australia, Crawley, Australia
3 shared publications Ghulam Mubashar Hassan
University of Western Australia
2 shared publications- Ghulam Mubashar Hassan
Computer Science and Software Engineering, The University of Western Australia, Perth, Australia
2 shared publications Godfrey Mukwada
School of Physics, Mathematics and Computing, The University of Western Australia, Crawley, Australia
2 shared publications
Latest Publications
- Open Access
- 13 January 2025
- Published by Springer Nature in Physical and Engineering Sciences in Medicine
- Vol. 48 (1) , 301-316
Guidance on selecting and evaluating AI auto-segmentation systems in clinical radiotherapy: insights from a six-vendor analysis
Artificial Intelligence (AI) based auto-segmentation has demonstrated numerous benefits to clinical radiotherapy workflows. However, the rapidly changing regulatory, research, and market environment presents challenges around selecting and evaluating the most suitable solution. To support the clinical adoption of AI auto-segmentation systems, Selection Criteria recommendations were developed to enable a holistic evaluation of vendors, considering not only raw performance but associated risks uniquely related to the clinical deployment of AI. In-house experience and key bodies of work on ethics, standards, and best practices for AI in Radiation Oncology were reviewed to inform selection criteria and evaluation strategies. A retrospective analysis using the criteria was performed across six vendors, including a quantitative assessment using five metrics (Dice, Hausdorff Distance, Average Surface Distance, Surface Dice, Added Path Length) across 20 head and neck, 20 thoracic, and 19 male pelvis patients for AI models as of March 2023. A total of 47 selection criteria were identified across seven categories. A retrospective analysis showed that overall no vendor performed exceedingly well, with systematically poor performance in Data Security & Responsibility, Vendor Support Tools, and Transparency & Ethics. In terms of raw performance, vendors varied widely from excellent to poor. As new regulations come into force and the scope of AI auto-segmentation systems adapt to clinical needs, continued interest in ensuring safe, fair, and transparent AI will persist. The selection and evaluation framework provided herein aims to promote user confidence by exploring the breadth of clinically relevant factors to support informed decision-making.
- 13 January 2025
- Published by Springer Nature in Physical and Engineering Sciences in Medicine
- Vol. 48 (1) , 301-316
Open AccessGuidance on selecting and evaluating AI auto-segmentation systems in clinical radiotherapy: insights from a six-vendor analysis
Artificial Intelligence (AI) based auto-segmentation has demonstrated numerous benefits to clinical radiotherapy workflows. However, the rapidly changing regulatory, research, and market environment presents challenges around selecting and evaluating the most suitable solution. To support the clinical adoption of AI auto-segmentation systems, Selection Criteria recommendations were developed to enable a holistic evaluation of vendors, considering not only raw performance but associated risks uniquely related to the clinical deployment of AI. In-house experience and key bodies of work on ethics, standards, and best practices for AI in Radiation Oncology were reviewed to inform selection criteria and evaluation strategies. A retrospective analysis using the criteria was performed across six vendors, including a quantitative assessment using five metrics (Dice, Hausdorff Distance, Average Surface Distance, Surface Dice, Added Path Length) across 20 head and neck, 20 thoracic, and 19 male pelvis patients for AI models as of March 2023. A total of 47 selection criteria were identified across seven categories. A retrospective analysis showed that overall no vendor performed exceedingly well, with systematically poor performance in Data Security & Responsibility, Vendor Support Tools, and Transparency & Ethics. In terms of raw performance, vendors varied widely from excellent to poor. As new regulations come into force and the scope of AI auto-segmentation systems adapt to clinical needs, continued interest in ensuring safe, fair, and transparent AI will persist. The selection and evaluation framework provided herein aims to promote user confidence by exploring the breadth of clinically relevant factors to support informed decision-making.
- Open Access
- 30 January 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (3) , 035014
Transformer CycleGAN with uncertainty estimation for CBCT based synthetic CT in adaptive radiotherapy
Objective . Clinical implementation of synthetic CT (sCT) from cone-beam CT (CBCT) for adaptive radiotherapy necessitates a high degree of anatomical integrity, Hounsfield unit (HU) accuracy, and image quality. To achieve these goals, a vision-transformer and anatomically sensitive loss functions are described. Better quantification of image quality is achieved using the alignment-invariant Fréchet inception distance (FID), and uncertainty estimation for sCT risk prediction is implemented in a scalable plug-and-play manner. Approach . Baseline U-Net, generative adversarial network (GAN), and CycleGAN models were trained to identify shortcomings in each approach. The proposed CycleGAN-Best model was empirically optimized based on a large ablation study and evaluated using classical image quality metrics, FID, gamma index, and a segmentation analysis. Two uncertainty estimation methods, Monte-Carlo Dropout (MCD) and test-time augmentation (TTA), were introduced to model epistemic and aleatoric uncertainty. Main results . FID was correlated to blind observer image quality scores with a Correlation Coefficient of −0.83, validating the metric as an accurate quantifier of perceived image quality. The FID and mean absolute error (MAE) of CycleGAN-Best was 42.11 ± 5.99 and 25.00 ± 1.97 HU, compared to 63.42 ± 15.45 and 31.80 HU for CycleGAN-Baseline, and 144.32 ± 20.91 and 68.00 ± 5.06 HU for the CBCT, respectively. Gamma 1%/1 mm pass rates were 98.66 ± 0.54% for CycleGAN-Best, compared to 86.72 ± 2.55% for the CBCT. TTA and MCD-based uncertainty maps were well spatially correlated with poor synthesis outputs. Significance . Anatomical accuracy was achieved by suppressing CycleGAN-related artefacts. FID better discriminated image quality, where alignment-based metrics such as MAE erroneously suggest poorer outputs perform better. Uncertainty estimation for sCT was shown to correlate with poor outputs and has clinical relevancy toward model risk assessment and quality assurance. The proposed model and accompanying evaluation and risk assessment tools are necessary additions to achieve clinically robust sCT generation models.
- 30 January 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (3) , 035014
Open AccessTransformer CycleGAN with uncertainty estimation for CBCT based synthetic CT in adaptive radiotherapy
Objective . Clinical implementation of synthetic CT (sCT) from cone-beam CT (CBCT) for adaptive radiotherapy necessitates a high degree of anatomical integrity, Hounsfield unit (HU) accuracy, and image quality. To achieve these goals, a vision-transformer and anatomically sensitive loss functions are described. Better quantification of image quality is achieved using the alignment-invariant Fréchet inception distance (FID), and uncertainty estimation for sCT risk prediction is implemented in a scalable plug-and-play manner. Approach . Baseline U-Net, generative adversarial network (GAN), and CycleGAN models were trained to identify shortcomings in each approach. The proposed CycleGAN-Best model was empirically optimized based on a large ablation study and evaluated using classical image quality metrics, FID, gamma index, and a segmentation analysis. Two uncertainty estimation methods, Monte-Carlo Dropout (MCD) and test-time augmentation (TTA), were introduced to model epistemic and aleatoric uncertainty. Main results . FID was correlated to blind observer image quality scores with a Correlation Coefficient of −0.83, validating the metric as an accurate quantifier of perceived image quality. The FID and mean absolute error (MAE) of CycleGAN-Best was 42.11 ± 5.99 and 25.00 ± 1.97 HU, compared to 63.42 ± 15.45 and 31.80 HU for CycleGAN-Baseline, and 144.32 ± 20.91 and 68.00 ± 5.06 HU for the CBCT, respectively. Gamma 1%/1 mm pass rates were 98.66 ± 0.54% for CycleGAN-Best, compared to 86.72 ± 2.55% for the CBCT. TTA and MCD-based uncertainty maps were well spatially correlated with poor synthesis outputs. Significance . Anatomical accuracy was achieved by suppressing CycleGAN-related artefacts. FID better discriminated image quality, where alignment-based metrics such as MAE erroneously suggest poorer outputs perform better. Uncertainty estimation for sCT was shown to correlate with poor outputs and has clinical relevancy toward model risk assessment and quality assurance. The proposed model and accompanying evaluation and risk assessment tools are necessary additions to achieve clinically robust sCT generation models.
- Open Access
- 17 October 2023
- Published by Springer Nature in Scientific Reports
- Vol. 13 (1) , 1-14
Quantitative [68Ga]Ga-PSMA-11 PET biomarkers for the analysis of lesion-level progression in biochemically recurrent prostate cancer: a multicentre study
[68Ga]Ga-PSMA-11 PET has become the standard imaging modality for biochemically recurrent (BCR) prostate cancer (PCa). However, its prognostic value in assessing response at this stage remains uncertain. The study aimed to assess the prognostic significance of radiographic patient-level patterns of progression derived from lesion-level biomarker quantitation in metastatic disease sites. A total of 138 BCR PCa patients with both baseline and follow-up [68Ga]Ga-PSMA-11 PET scans were included in this analysis. Tumour response was quantified at the lesion level using commonly used quantitative parameters (SUVmean, SUVmax, SUVpeak, volume), and patients were classified as systemic, mixed, or no-progression based on these response classifications. A total of 328 matched lesions between baseline and follow-up scans were analysed. The results showed that systemic progressors had a significantly higher risk of death than patients with no progression with SUVmean demonstrating the highest prognostic value (HR = 5.70, 95% CI = 2.63–12.37, p < 0.001, C-Index = 0.69). Moreover, progressive disease as measured by SUVmean using the radiographic PSMA PET Progression Criteria (rPPP) was found to be significantly prognostic for patient overall survival (HR = 3.67, 95% CI = 1.82–7.39, p < 0.001, C-Index = 0.65). This work provides important evidence supporting the prognostic utility of PSMA response quantitation in the BCR setting.
- 17 October 2023
- Published by Springer Nature in Scientific Reports
- Vol. 13 (1) , 1-14
Open AccessQuantitative [68Ga]Ga-PSMA-11 PET biomarkers for the analysis of lesion-level progression in biochemically recurrent prostate cancer: a multicentre study
[68Ga]Ga-PSMA-11 PET has become the standard imaging modality for biochemically recurrent (BCR) prostate cancer (PCa). However, its prognostic value in assessing response at this stage remains uncertain. The study aimed to assess the prognostic significance of radiographic patient-level patterns of progression derived from lesion-level biomarker quantitation in metastatic disease sites. A total of 138 BCR PCa patients with both baseline and follow-up [68Ga]Ga-PSMA-11 PET scans were included in this analysis. Tumour response was quantified at the lesion level using commonly used quantitative parameters (SUVmean, SUVmax, SUVpeak, volume), and patients were classified as systemic, mixed, or no-progression based on these response classifications. A total of 328 matched lesions between baseline and follow-up scans were analysed. The results showed that systemic progressors had a significantly higher risk of death than patients with no progression with SUVmean demonstrating the highest prognostic value (HR = 5.70, 95% CI = 2.63–12.37, p < 0.001, C-Index = 0.69). Moreover, progressive disease as measured by SUVmean using the radiographic PSMA PET Progression Criteria (rPPP) was found to be significantly prognostic for patient overall survival (HR = 3.67, 95% CI = 1.82–7.39, p < 0.001, C-Index = 0.65). This work provides important evidence supporting the prognostic utility of PSMA response quantitation in the BCR setting.
- Top Cited PapersOpen Access
- 18 July 2022
- Published by Wiley in Medical Physics
- Vol. 49 (9) , 6019-6054
Deep learning methods for enhancing cone‐beam CT image quality toward adaptive radiation therapy: A systematic review
The use of deep learning (DL) to improve cone‐beam CT (CBCT) image quality has gained popularity as computational resources and algorithmic sophistication have advanced in tandem. CBCT imaging has the potential to facilitate online adaptive radiation therapy (ART) by utilizing up‐to‐date patient anatomy to modify treatment parameters before irradiation. Poor CBCT image quality has been an impediment to realizing ART due to the increased scatter conditions inherent to cone‐beam acquisitions. Given the recent interest in DL applications in radiation oncology, and specifically DL for CBCT correction, we provide a systematic theoretical and literature review for future stakeholders. The review encompasses DL approaches for synthetic CT generation, as well as projection domain methods employed in the CBCT correction literature. We review trends pertaining to publications from January 2018 to April 2022 and condense their major findings—with emphasis on study design and DL techniques. Clinically relevant endpoints relating to image quality and dosimetric accuracy are summarized, highlighting gaps in the literature. Finally, we make recommendations for both clinicians and DL practitioners based on literature trends and the current DL state‐of‐the‐art methods utilized in radiation oncology.
- 18 July 2022
- Published by Wiley in Medical Physics
- Vol. 49 (9) , 6019-6054
Top Cited PapersOpen AccessDeep learning methods for enhancing cone‐beam CT image quality toward adaptive radiation therapy: A systematic review
The use of deep learning (DL) to improve cone‐beam CT (CBCT) image quality has gained popularity as computational resources and algorithmic sophistication have advanced in tandem. CBCT imaging has the potential to facilitate online adaptive radiation therapy (ART) by utilizing up‐to‐date patient anatomy to modify treatment parameters before irradiation. Poor CBCT image quality has been an impediment to realizing ART due to the increased scatter conditions inherent to cone‐beam acquisitions. Given the recent interest in DL applications in radiation oncology, and specifically DL for CBCT correction, we provide a systematic theoretical and literature review for future stakeholders. The review encompasses DL approaches for synthetic CT generation, as well as projection domain methods employed in the CBCT correction literature. We review trends pertaining to publications from January 2018 to April 2022 and condense their major findings—with emphasis on study design and DL techniques. Clinically relevant endpoints relating to image quality and dosimetric accuracy are summarized, highlighting gaps in the literature. Finally, we make recommendations for both clinicians and DL practitioners based on literature trends and the current DL state‐of‐the‐art methods utilized in radiation oncology.
- 22 October 2021
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 66 (21) , 215007
A convolutional neural network for estimating cone-beam CT intensity deviations from virtual CT projections
Extending cone-beam CT (CBCT) use toward dose accumulation and adaptive radiotherapy (ART) necessitates more accurate HU reproduction since cone-beam geometries are heavily degraded by photon scatter. This study proposes a novel method which aims to demonstrate how deep learning based on phantom data can be used effectively for CBCT intensity correction in patient images. Four anthropomorphic phantoms were scanned on a CBCT and conventional fan-beam CT system. Intensity correction is performed by estimating the cone-beam intensity deviations from prior information contained in the CT. Residual projections were extracted by subtraction of raw cone-beam projections from virtual CT projections. An improved version of U-net is utilized to train on a total of 2001 projection pairs. Once trained, the network could estimate intensity deviations from input patient head and neck raw projections. The results from our novel method showed that corrected CBCT images improved the (contrast-to-noise ratio) with respect to uncorrected reconstructions by a factor of 2.08. The mean absolute error and structural similarity index improved from 318 HU to 74 HU and 0.750 to 0.812 respectively. Visual assessment based on line-profile measurements and difference image analysis indicate the proposed method reduced noise and the presence of beam-hardening artefacts compared to uncorrected and manufacturer reconstructions. Projection domain intensity correction for cone-beam acquisitions of patients was shown to be feasible using a convolutional neural network trained on phantom data. The method shows promise for further improvements which may eventually facilitate dose monitoring and ART in the clinical radiotherapy workflow.
- 22 October 2021
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 66 (21) , 215007
A convolutional neural network for estimating cone-beam CT intensity deviations from virtual CT projections
Extending cone-beam CT (CBCT) use toward dose accumulation and adaptive radiotherapy (ART) necessitates more accurate HU reproduction since cone-beam geometries are heavily degraded by photon scatter. This study proposes a novel method which aims to demonstrate how deep learning based on phantom data can be used effectively for CBCT intensity correction in patient images. Four anthropomorphic phantoms were scanned on a CBCT and conventional fan-beam CT system. Intensity correction is performed by estimating the cone-beam intensity deviations from prior information contained in the CT. Residual projections were extracted by subtraction of raw cone-beam projections from virtual CT projections. An improved version of U-net is utilized to train on a total of 2001 projection pairs. Once trained, the network could estimate intensity deviations from input patient head and neck raw projections. The results from our novel method showed that corrected CBCT images improved the (contrast-to-noise ratio) with respect to uncorrected reconstructions by a factor of 2.08. The mean absolute error and structural similarity index improved from 318 HU to 74 HU and 0.750 to 0.812 respectively. Visual assessment based on line-profile measurements and difference image analysis indicate the proposed method reduced noise and the presence of beam-hardening artefacts compared to uncorrected and manufacturer reconstructions. Projection domain intensity correction for cone-beam acquisitions of patients was shown to be feasible using a convolutional neural network trained on phantom data. The method shows promise for further improvements which may eventually facilitate dose monitoring and ART in the clinical radiotherapy workflow.