Abstract
Compared with the fundamental loss, the harmonic losses become very complicated because of the coupling between the power supply harmonics and the motor harmonics. To dispose of this problem, a multislice 2-D finite element model considering the interbar currents and a fast rotor harmonics identification method is employed to identify the harmonics of the rotor current density and flux density of the inverter-fed induction motor (IM). Considering the complex coupling phenomenon of time–space harmonics, a two-term iron model with piecewise-defined variable coefficients (PVCIL model) and a finite element analysis (FEA)-based copper loss method are then used to calculate the iron and copper loss components of the inverter-fed IM. Finally, based on the introduced methods, both the electromagnetic field and different losses terms of the same 5.5-kW inverter-fed IM under different load and supply conditions are calculated and analyzed. The experimental validation of those two losses’ calculation methods is performed on a 5.5-kW IM with different operating conditions. The results obtained in this article can provide the theoretical basis for targeted harmonic elimination and loss reduction in the design phase of the inverter-fed IM.
Funding Information
  • National Natural Science Foundation of China (51977077)
  • Key Laboratory of Special Machine and High Voltage Apparatus Shenyang University of Technology, Ministry of Education, China (KFKT202006)
  • Guangxi Young and Middle-Aged Scientific Research Basic Ability Promotion Project, China (2020KY01009)

This publication has 46 references indexed in Scilit: