A Minibatch Alternating Projections Algorithm for Robust and Efficient Magnitude Least-Squares RF Pulse Design in MRI
- 11 December 2024
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 44 (3) , 1556-1567
Abstract
A magnitude-least-squares radiofrequency pulse design algorithm is reported which uses interleaved exact and stochastically-generated inexact updates to escape local minima and find low-cost solutions. Inexact updates are performed using a small randomly selected minibatch of the available B 1 + measurements to update RF pulse weights, which perturbs the sequence of alternating projections. Applications to RF shimming, parallel transmit spokes RF pulse design, and spectral-spatial RF pulse design are considered. Numerical and simulation studies characterized the optimal minibatch size, which was found to consistently produce lower power and lower RMSE solutions across subjects, coil geometries, B 1 + resolutions and orientations. The method was validated in-vivo at 7 Tesla and produced improvements in image quality in a slice-byslice RF-shimmed imaging sequence. Compared to conventional methods, the pulse design method can more robustly design RF pulses that correct for B 1 + inhomogeneities at ultra-high field strengths, and enable pulse designs to be completed with increased computational efficiency.Keywords
All Related Versions
Funding Information
- U.S. NIH (R01 EB016695)
This publication has 40 references indexed in Scilit:
- Magnitude least squares optimization for parallel radio frequency excitation design demonstrated at 7 Tesla with eight channelsMagnetic Resonance in Medicine, 2008
- Parallel RF transmission with eight channels at 3 TeslaMagnetic Resonance in Medicine, 2006
- Exploring the limits of RF shimming for high‐field MRI of the human headMagnetic Resonance in Medicine, 2006
- Spatial domain method for the design of RF pulses in multicoil parallel excitationMagnetic Resonance in Medicine, 2006
- Fast‐kzthree‐dimensional tailored radiofrequency pulse for reducedB1inhomogeneityMagnetic Resonance in Medicine, 2006
- Transmit and receive transmission line arrays for 7 Tesla parallel imagingMagnetic Resonance in Medicine, 2005
- Spatial resolution of numerical models of man and calculated specific absorption rate using the FDTD method: A study at 64 MHz in a magnetic resonance imaging coilJournal of Magnetic Resonance Imaging, 2003
- Analysis of wave behavior in lossy dielectric samples at high fieldMagnetic Resonance in Medicine, 2002
- Dualband spectral‐spatial RF pulses for prostate MR spectroscopic imagingMagnetic Resonance in Medicine, 2001
- Radio frequency magnetic field mapping of a 3 Tesla birdcage coil: Experimental and theoretical dependence on sample propertiesMagnetic Resonance in Medicine, 2001