    Development of RF Probes and Preamplifiers for MRI at Low Fields

    by Charlotte R. Sappo, Jonathan B. Martin, Millie A. Barron, Selin Kandemir, Xinqiang Yan, John C. Gore

    Magnetic resonance imaging (MRI) systems operating at low magnetic fields ( T) have experienced renewed interest due to the emergence of portable, point‐of‐care (POC) scanners, and new approaches to mitigating the intrinsically lower signal‐to‐noise ratios (SNR). The performance of radiofrequency (RF) components is a large factor in determining overall system sensitivity. In contrast to conventional MRI, at higher fields where SNR is typically sample‐noise dominated, many low field (LF) systems operate in a coil‐noise dominated regime, requiring careful optimization of RF coil design, conductor losses, and receiver electronics. This manuscript surveys RF coil technologies and associated hardware considerations for MRI systems operating below approximately 0.18T, within the range that we designate as low field in this manuscript (0–250 mT). We begin by revisiting early low‐field imaging systems and the historical development of RF coil architectures for large‐volume imaging. The fundamental noise mechanisms governing low‐frequency MR detection are then examined, including Johnson noise in conductors, sample‐induced losses, receiver noise figure, and electromagnetic interference (EMI). Design strategies for improving sensitivity are discussed, including conductor optimization (e.g., Litz wire), coil geometry selection such as solenoidal and saddle configurations, and methods for managing coil bandwidth and quality factor. Recent developments in transmit‐receive switching, preamplifier design, EMI mitigation, and coil‐preamplifier co‐design are also reviewed. Finally, we highlight emerging directions for RF hardware development in low‐field MRI, including RF coils for encoding, multi‐element receive arrays for parallel imaging, and receiver architectures inspired by related modalities such as magnetic particle imaging and ultrasound. Continued advances in RF coil and receiver‐chain design will be essential for improving sensitivity and enabling low‐field MRI systems for clinical and research applications.


  • Open Access

    Diffusion imaging with a pulsed radiofrequency gradient spin-echo

    by Millie A. Barron, Charlotte R. Sappo, Kevin D. Harkins, Junzhong Xu, John C. Gore, Jonathan B. Martin

  • Open Access

    Radiofrequency field gradient encoding methods and applications for magnetic resonance imaging

    by Charlotte R. Sappo, Millie A. Barron, R. Todd Constable, Gigi Galiana, Aaron R. Purchase, Sai Abitha Srinivas, Efraín Torres, Christopher E. Vaughn, Jonathan B. Martin


  • A Minibatch Alternating Projections Algorithm for Robust and Efficient Magnitude Least-Squares RF Pulse Design in MRI

    by Jonathan B. Martin, Charlotte R. Sappo, Benjamin M. Hardy, William A. Grissom

    A magnitude-least-squares radiofrequency pulse design algorithm is reported which uses interleaved exact and stochastically-generated inexact updates to escape local minima and find low-cost solutions. Inexact updates are performed using a small randomly selected minibatch of the available B 1 + measurements to update RF pulse weights, which perturbs the sequence of alternating projections. Applications to RF shimming, parallel transmit spokes RF pulse design, and spectral-spatial RF pulse design are considered. Numerical and simulation studies characterized the optimal minibatch size, which was found to consistently produce lower power and lower RMSE solutions across subjects, coil geometries, B 1 + resolutions and orientations. The method was validated in-vivo at 7 Tesla and produced improvements in image quality in a slice-byslice RF-shimmed imaging sequence. Compared to conventional methods, the pulse design method can more robustly design RF pulses that correct for B 1 + inhomogeneities at ultra-high field strengths, and enable pulse designs to be completed with increased computational efficiency.


  • Open Access

    Paramagnetic salt and agarose recipes for phantoms with desired T1 and T2 values for low‐field MRI

    by Kalina V. Jordanova, Carla C. Fraenza, Michele N. Martin, Ye Tian, Sheng Shen, Christopher E. Vaughn, Kevin J. Walsh, Casey Walsh, Charlotte R. Sappo, Stephen E. Ogier, et al.

    Tissue‐mimicking reference phantoms are indispensable for the development and optimization of magnetic resonance (MR) measurement sequences. Phantoms have greatest utility when they mimic the MR signals arising from tissue physiology; however, many of the properties underlying these signals, including tissue relaxation characteristics, can vary as a function of magnetic field strength. There has been renewed interest in magnetic resonance imaging (MRI) at field strengths less than 1 T, and phantoms developed for higher field strengths may not be physiologically relevant at these lower fields. This work focuses on developing materials with specific relaxation properties for lower magnetic field strengths. Specifically, we developed recipes that can be used to create synthetic samples for target nuclear magnetic resonance relaxation values for fields between 0.0065 and 0.55 T. and mixing models for agarose‐based gels doped with a paramagnetic salt (one of CuSO4, GdCl3, MnCl2, or NiCl2) were created using relaxation measurements of synthetic gel samples at 0.0065, 0.064, and 0.55 T. Measurements were evaluated for variability with respect to measurement repeatability and changing synthesis protocol or laboratory temperature. The mixing models were used to identify formulations of agarose and salt composition to approximately mimic the relaxation times of five neurological tissues (blood, cerebrospinal fluid, fat, gray matter, and white matter) at 0.0065, 0.0475, 0.05, 0.064, and 0.55 T. These mimic sample formulations were measured at each field strength. Of these samples, the GdCl3 and NiCl2 measurements were closest to the target tissue relaxation times. The GdCl3 or NiCl2 mixing model recipes are recommended for creating target relaxation samples below 0.55 T. This work can help development of MRI methods and applications for low‐field systems and applications.


  • On the design and manufacturing of miniaturized microstripline power splitters for driving multicoil transmit arrays with arbitrary ratios at 7 T

    by Charlotte R. Sappo, Gabriela L. Gallego, William A. Grissom, Xinqiang Yan

    The purpose of the current study was to implement unequal microstrip power splitters for parallel transmission at 7 T that are optimized for size and loss and that can be configured for a wide range of power ratios. The splitters will enable the use of more transmit coils without a corresponding increase in the number of transmit channels or amplifiers to control specific absorption rate, shorten RF pulses, and shim inhomogeneous RF fields. Wilkinson unequal power splitters based on a novel microstrip network design were optimized to minimize their size under 8 cm in length and 9 cm in width, enabling them to be included in coil housing or cascaded in multiple stages. Splitters were designed and constructed for a wide range of output power ratios at 298 MHz. Simulations and bench tests were performed for each ratio, and a methodology was established to adapt the designs to other ratios and frequencies. The designs and code are open source and can be reproduced as is or reconfigured. The single‐stage designs achieved good matches and isolations between output ports (worst isolation −15.9 dB, worst match −15.1 dB). A two‐stage cascaded (one input to four outputs) power splitter with 1:2.5, 1:10, 1:3, and 1:6 ratio outputs was constructed. The worst isolation between output ports was −19.7 dB in simulation and the worst match of the three ports was −17.8 dB. The measured ratios for one‐ and two‐stage boards were within 10% of the theoretical ratios. The power‐handling capability of the smallest trace was approximately 70 W. Power loss for the one‐ and two‐stage boards ranged from 1% to 3% in simulation compared with 5.1% to 7.2% on the bench. It was concluded that Wilkinson unequal microstrip power splitters can be implemented with a small board size (low height) and low loss, and across a wide range of output power ratios. The splitters can be cascaded in multiple stages while maintaining the expected ratios and low loss. This will enable the construction of large fixed transmit array‐compression matrices with low loss.


  • Dual-Tuned Lattice Balun for Multi-Nuclear MRI and MRS

    by Yue Zhu, Charlotte R. Sappo, William A. Grissom, John C. Gore, Xinqiang Yan

    Balun or trap circuits are critical components for suppressing common-mode currents flowing on the outer conductors of coaxial cables in RF coil systems for Magnetic Resonance Imaging (MRI) and Magnetic Resonance Spectroscopy (MRS). Common-mode currents affect coils’ tuning and matching, induce losses, pick up extra noise from the surrounding environment, lead to undesired cross-talk, and cause safety concerns in animal and human imaging. First proposed for microwave antenna applications, the Lattice balun has been widely used in MRI coils. It has a small footprint and can be easily integrated with coil tuning/matching circuits. However, the Lattice balun is typically a single-tuned circuit and cannot be used for multi-nuclear MRI and MRS with two RF frequencies. This work describes a dual-tuned Lattice balun design that is suitable for multi-nuclear MRI/MRS. It was first analyzed theoretically to derive component values. RF circuit simulations were then performed to validate the theoretical analysis and provide guidance for practical construction. Based on the simulation results, a dual-tuned balun circuit was built for 7T 1 H/ 23 Na MRI and bench tested. The fabricated dual-tuned balun exhibits superior performance at the Larmor frequencies of both 1 H and 23 Na, with less than 0.15 dB insertion loss and better than 17 dB common-mode rejection ratio at both frequencies.


  • A 31‐channel integrated “AC/DC” B0 shim and radiofrequency receive array coil for improved 7T MRI

    by Jason P. Stockmann, Nicolas S. Arango, Thomas Witzel, Azma Mareyam, Charlotte Sappo, Jiazheng Zhou, Lucas Jenkins, Lincoln Craven‐Brightman, Eugene Milshteyn, Mathias Davids, et al.

    Purpose: To test an integrated “AC/DC” array approach at 7T, where B0 inhomogeneity poses an obstacle for functional imaging, diffusion‐weighted MRI, MR spectroscopy, and other applications.Methods: A close‐fitting 7T 31‐channel (31‐ch) brain array was constructed and tested using combined Rx and ΔB0 shim channels driven by a set of rapidly switchable current amplifiers. The coil was compared to a shape‐matched 31‐ch reference receive‐only array for RF safety, signal‐to‐noise ratio (SNR), and inter‐element noise correlation. We characterize the coil array’s ability to provide global and dynamic (slice‐optimized) shimming using ΔB0 field maps and echo planar imaging (EPI) acquisitions.Results: The SNR and average noise correlation were similar to the 31‐ch reference array. Global and slice‐optimized shimming provide 11% and 40% improvements respectively compared to baseline second‐order spherical harmonic shimming. Birdcage transmit coil efficiency was similar for the reference and AC/DC array setups.Conclusion: Adding ΔB0 shim capability to a 31‐ch 7T receive array can significantly boost 7T brain B0 homogeneity without sacrificing the array’s rdiofrequency performance, potentially improving ultra‐high field neuroimaging applications that are vulnerable to off‐resonance effects.


  • External Dynamic InTerference Estimation and Removal (EDITER) for low field MRI

    by Sai Abitha Srinivas, Stephen F. Cauley, Jason P. Stockmann, Charlotte R. Sappo, Christopher E. Vaughn, Lawrence L. Wald, William A. Grissom, Clarissa Z. Cooley

    Purpose: Point‐of‐care MRI requires operation outside of Faraday shielded rooms normally used to block image‐degrading electromagnetic interference (EMI). To address this, we introduce the EDITER method (External Dynamic InTerference Estimation and Removal), an external sensor‐based method to retrospectively remove image artifacts from time‐varying external interference sources.Theory and Methods: The method acquires data from multiple EMI detectors (tuned receive coils as well as untuned electrodes placed on the body) simultaneously with the primary MR coil during and between image data acquisition. We calculate impulse response functions dynamically that map the data from the detectors to the time varying artifacts then remove the transformed detected EMI from the MR data. Performance of the EDITER algorithm was assessed in phantom and in vivo imaging experiments in an 80 mT portable brain MRI in a controlled EMI environment and with an open 47.5 mT MRI scanner in an uncontrolled EMI setting.Results: In the controlled setting, the effectiveness of the EDITER technique was demonstrated for specific types of introduced EMI sources with up to a 97% reduction of structured EMI and up to 76% reduction of broadband EMI in phantom experiments. In the uncontrolled EMI experiments, we demonstrate EMI reductions of up to 99% using an electrode and pick‐up coil in vivo. We demonstrate up to a nine‐fold improvement in image SNR with the method.Conclusion: The EDITER technique is a flexible and robust method to improve image quality in portable MRI systems with minimal passive shielding and could reduce the reliance of MRI on shielded rooms and allow for truly portable MRI.