Detection of beat-to-beat intervals from wrist photoplethysmography in patients with sinus rhythm and atrial fibrillation after surgery
Open Access
- 1 March 2018
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 133-136
Abstract
Wrist photoplethysmography (PPG) allows unobtrusive monitoring of the heart rate (HR). PPG is affected by the capillary blood perfusion and the pumping function of the heart, which generally deteriorate with age and due to the presence of cardiac arrhythmia. The performance of wrist PPG in monitoring beat-to-beat HR in older patients with arrhythmia has not been reported earlier. We monitored PPG from wrist in 18 patients recovering from surgery in the post-anesthesia care unit, and evaluated the inter-beat interval (IBI) detection accuracy against ECG based R-to-R intervals (RRI). Nine subjects had sinus rhythm (SR, 68.0y ± 10.2y, 6 males) and nine subjects had atrial fibrillation (AF, 71.3y ± 7.8y, 4 males) during the recording. For the SR group, 99.44% of the beats were correctly identified, 2.39% extra beats were detected, and the mean absolute error (MAE) was 7.34 ms. For the AF group, 97.49% of the heartbeats were correctly identified, 2.26% extra beats were detected, and the MAE was 14.31 ms. IBI from the PPG were hence in close agreement with the ECG reference in both groups. The results suggest that wrist PPG provides a comfortable alternative to ECG during low motion and can be used for long-term monitoring and screening of AF episodes.Keywords
All Related Versions
This publication has 12 references indexed in Scilit:
- Evaluation of accuracy and reliability of PulseOn optical heart rate monitoring device2015
- Evaluation of wearable consumer heart rate monitors based on photopletysmography2014
- Validation of a wrist monitor for accurate estimation of RR intervals during sleep2013
- How accurate is pulse rate variability as an estimate of heart rate variability?International Journal of Cardiology, 2013
- Atrial Fibrillation Detection Using an iPhone 4SIEEE Transactions on Biomedical Engineering, 2012
- Effects of exercise intensity and duration on nocturnal heart rate variability and sleep qualityEuropean Journal of Applied Physiology, 2011
- Comparison of two systems for long-term heart rate variability monitoring in free-living conditions - a pilot studyBioMedical Engineering OnLine, 2011
- Comparison of three mobile devices for measuring R–R intervals and heart rate variability: Polar S810i, Suunto t6 and an ambulatory ECG systemEuropean Journal of Applied Physiology, 2010
- Heart rate variability: a reviewMedical & Biological Engineering & Computing, 2006
- Analysis of heart rate variability in the presence of ectopic beats using the heart timing signalIEEE Transactions on Biomedical Engineering, 2003