Robotic Intracellular Pressure Measurement Using Micropipette Electrode
Open Access
Abstract
Intracellular pressure, a key physical parameter of the intracellular environment, has been found to regulate multiple cell physiological activities and impact cell micromanipulation results. The intracellular pressure may reveal the mechanism of these cells’ physiological activities or improve the micro-manipulation accuracy for cells. The involvement of specialized and expensive devices and the significant damage to cell viability that the current intracellular pressure measurement methods cause significantly limit their wide applications. This paper proposes a robotic intracellular pressure measurement method using a traditional micropipette electrode system setup. First, the measured resistance of the micropipette inside the culture medium is modeled to analyze its variation trend when the pressure inside the micropipette increases. Then, the concentration of KCl solution filled inside the micropipette electrode that is suitable for intracellular pressure measurement is determined according to the tested electrode resistance–pressure relationship; 1 mol/L KCl solution is our final choice. Further, the measurement resistance of the micropipette electrode inside the cell is modeled to measure the intracellular pressure through the difference in key pressure before and after the release of the intracellular pressure. Based on the above work, a robotic measurement procedure of the intracellular pressure is established based on a traditional micropipette electrode system. The experimental results on porcine oocytes demonstrate that the proposed method can operate on cells at an average speed of 20~40 cells/day with measurement efficiency comparable to the related work. The average repeated error of the relationship between the measured electrode resistance and the pressure inside the micropipette electrode is less than 5%, and no observable intracellular pressure leakage was found during the measurement process, both guaranteeing the measurement accuracy of intracellular pressure. The measured results of the porcine oocytes are in accordance with those reported in related work. Moreover, a 90% survival rate of operated oocytes was obtained after measurement, proving limited damage to cell viability. Our method does not rely on expensive instruments and is conducive to promotion in daily laboratories.Keywords
Funding Information
- National Natural Science Foundation of China (62027812, 62273186, 2019IRS05)
- Beijing Advanced Innovation Center for Intelligent Robots and Systems, Beijing Institute of Technology (62027812, 62273186, 2019IRS05)
This publication has 24 references indexed in Scilit:
- A Multimodal System with Synergistic Effects of Magneto-Mechanical, Photothermal, Photodynamic and Chemo Therapies of Cancer in Graphene-Quantum Dot-Coated Hollow Magnetic NanospheresTheranostics, 2016
- Effects of Physiologic Mechanical Stimulation on Embryonic Chick Cardiomyocytes Using a Microfluidic Cardiac Cell Culture ModelAnalytical Chemistry, 2015
- Robotic Cell Rotation Based on the Minimum Rotation ForceIEEE Transactions on Automation Science and Engineering, 2014
- Generation of compartmentalized pressure by a nuclear piston governs cell motility in a 3D matrixScience, 2014
- Direct Measurement of Intracellular PressureCurrent Protocols in Cell Biology, 2014
- Robotic enuleation for oocytes2014
- A novel pneumatic micropipette aspiration method using a balance pressure modelReview of Scientific Instruments, 2013
- Mechanical Control of Stem Cell DifferentiationRegenerative Medicine, 2011
- A Protocol For Digesting Internal Soft Tissues And Mounting Spiders For Scanning Electron MicroscopyThe Journal of Arachnology, 2007
- Cell differentiation by mechanical stressThe FASEB Journal, 2001