Is the test result correct? A questionnaire study of blood collection practices in primary health care
- 13 July 2010
- journal article
- Published by Wiley in Journal of Evaluation in Clinical Practice
- Vol. 16 (4) , 707-711
Abstract
Rationale, aims and objectives Venous blood tests are important for clinical decision making. Most errors in blood testing are due to human errors before the blood samples reach the laboratory. The present study was designed to investigate venous blood sampling (VBS) practices in primary health care centres (PHCs) compared with clinical laboratory staff.Method A cross‐sectional survey of 70 PHCs and two clinical laboratories is conducted. All staff responsible for VBS (317 respondents, response rate 94%) completed a questionnaire on VBS practices.Results Instructions for VBS were not followed in the surveyed PHCs. For example, only 54% reported that they always identified the patient by using name/Swedish identification number and only 5% reported that they always used photo‐ID, the two preferred means for patient identification. Only 12% reported that they always released venous stasis as soon as possible. Fewer PHC staff than clinical laboratory staff reported correct VBS practices. For example, 54% of the PHC staff reported that they always identified the patient by name and Swedish identification number, as compared with 95% of the clinical laboratory staff (P < 0.001). Documented VBS routines and re‐education in VBS were not clearly associated with reported correct VBS practices.Conclusions In the surveyed PHCs, there are clinically important risks for misidentification of patients and erroneous test results, with consequences for the diagnosis and treatment of patients. Quality interventions, aimed at improving VBS practices, are needed to ensure patient safety.Keywords
This publication has 23 references indexed in Scilit:
- Preanalytical venous blood sampling practices demand improvement — A survey of test-request management, test-tube labelling and information search proceduresClinica Chimica Acta, 2008
- Prevalence and type of pre‐analytical problems for inpatients samples in coagulation laboratoryJournal of Evaluation in Clinical Practice, 2008
- Errors in a Stat Laboratory: Types and Frequencies 10 Years LaterClinical Chemistry, 2007
- Patient‐centred care – preanalytical factors demand attention: A questionnaire study of venous blood sampling and specimen handlingScandinavian Journal of Clinical and Laboratory Investigation, 2007
- Venous stasis and routine hematologic testingClinical and Laboratory Haematology, 2006
- Medical errors: impact on clinical laboratories and other critical areasClinical Biochemistry, 2004
- The truth about quality: medical usefulness and analytical reliability of laboratory testsClinica Chimica Acta, 2004
- Test result variation and the quality of evidence-based clinical guidelinesClinica Chimica Acta, 2004
- Clinical interpretation of reference intervals and reference limits. A plea for assay harmonizationClinical Chemistry and Laboratory Medicine (CCLM), 2004
- Problems in Laboratory Testing in Primary CareJAMA, 1996