JSJohan Söderberg

Johan Söderberg

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Johan Söderberg has a total of 13 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Associations between workplace affiliation and phlebotomy practices regarding patient identification and test request handling practices in primary healthcare centres: a multilevel model approach

    by Karin Nilsson, Christina Juthberg, Johan Söderberg, Karin Bölenius, Kjell Grankvist, Christine Brulin, Marie Lindkvist

    Clinical practice guidelines aim to enhance patient safety by reducing inappropriate variations in practice. Despite considerable efforts to enhance the use of clinical practice guidelines, adherence is often suboptimal. We investigated to what extent workplace affiliation explains variation of self-reported adherence to venous blood specimen collection regarding patient identification and test request handling practices, taking into consideration other primary healthcare centre and individual phlebotomist characteristics. Data were collected through a questionnaire survey of 164 phlebotomy staff from 25 primary healthcare centres in northern Sweden. To prevent the impact of a large-scale education intervention in 2008, only baseline data, collected over a 3-month period in 2006–2007, were used and subjected to descriptive statistics and multilevel logistic analyses. In two patient identification outcomes, stable high median odds ratios (MOR) were found in both the empty model, and in the adjusted full model including both individual and workplace factors. Our findings suggest that variances among phlebotomy staff can be largely explained by primary healthcare centre affiliation also when individual and workplace demographic characteristics were taken in consideration. Analyses showed phlebotomy staff at medium and large primary healthcare centres to be more likely to adhere to guidelines than staff at small centres. Furthermore, staff employed shorter time at worksite to be more likely to adhere than staff employed longer. Finally, staff performing phlebotomy every week or less were more likely to adhere than staff performing phlebotomy on a daily basis. Workplace affiliation largely explains variances in self-reported adherence to venous blood specimen collection guidelines for patient identification and test request handling practices among phlebotomy staff. Characteristics of the workplace, as well as of the individual phlebotomist, need to be identified in order to design strategies to improve clinical practice in this and other areas.


  • Open Access

    Impact of a large-scale educational intervention program on venous blood specimen collection practices

    by Karin Bölenius, Marie Lindkvist, Christine Brulin, Kjell Grankvist, Karin Nilsson, Johan Söderberg

    Phlebotomy performed with poor adherence to venous blood specimen collection (VBSC) guidelines jeopardizes patient safety and may lead to patient suffering and adverse events. A first questionnaire study demonstrated low compliance to VBSC guidelines, motivating an educational intervention of all phlebotomists within a county council. The aim was to evaluate the impact of a large-scale educational intervention program (EIP) on primary health care phlebotomists’ adherence to VBSC guidelines. We hypothesised that the EIP would improve phlebotomists’ VBSC practical performance.


  • Minor improvement of venous blood specimen collection practices in primary health care after a large-scale educational intervention

    by Karin Bölenius, Johan Söderberg, Johan Hultdin, Marie Lindkvist, Christine Brulin, Kjell Grankvist

    Background:Venous blood specimen collection is a common health care practice that has to follow strict guidelines, non-compliance among sampling staff may compromise patient safety. We evaluated a large-scale 2 h educational intervention that emphasised guideline adherence to assess possible improvements of venous blood specimen collection practices.Methods:Blood specimen haemolysis is usually caused by inadequate venous blood specimen collection and handling, reflecting overall pre-analytical handling. We monitored haemolysis of serum samples with haemolysis index corresponding to ≥150 mg/L of free haemoglobin for specimens sent from 11 primary health care centres and analysed on a Vitros 5,1 clinical chemistry analyser before (2008, n=6652 samples) and after (2010, n=6121 samples) the intervention.Results:The total percentage of haemolysed specimens was 11.8% compared to 10.5% (p=0.022) before the intervention. As groups, rural primary health care centres demonstrated a significant reduction [Odds ratios (OR)=0.744] of haemolysed specimens after intervention, whereas urban primary health care centres demonstrated a significant increase (OR=1.451) of haemolysis.Conclusions:A large-scale 2 h educational intervention to make venous blood specimen collection staff comply with guideline practices had minor effects on collection practices. Educational interventions may be effective in wards/care centres demonstrating venous blood specimen collection practices with larger deviations from guidelines.


  • Open Access

    A content validated questionnaire for assessment of self reported venous blood sampling practices

    by Karin Bölenius, Christine Brulin, Kjell Grankvist, Marie Lindkvist, Johan Söderberg

    Venous blood sampling is a common procedure in health care. It is strictly regulated by national and international guidelines. Deviations from guidelines due to human mistakes can cause patient harm. Validated questionnaires for health care personnel can be used to assess preventable "near misses"--i.e. potential errors and nonconformities during venous blood sampling practices that could transform into adverse events. However, no validated questionnaire that assesses nonconformities in venous blood sampling has previously been presented. The aim was to test a recently developed questionnaire in self reported venous blood sampling practices for validity and reliability.


  • Is the test result correct? A questionnaire study of blood collection practices in primary health care

    by Johan Söderberg, Olof Wallin, Kjell Grankvist, Christine Brulin

    Rationale, aims and objectives  Venous blood tests are important for clinical decision making. Most errors in blood testing are due to human errors before the blood samples reach the laboratory. The present study was designed to investigate venous blood sampling (VBS) practices in primary health care centres (PHCs) compared with clinical laboratory staff.Method  A cross‐sectional survey of 70 PHCs and two clinical laboratories is conducted. All staff responsible for VBS (317 respondents, response rate 94%) completed a questionnaire on VBS practices.Results  Instructions for VBS were not followed in the surveyed PHCs. For example, only 54% reported that they always identified the patient by using name/Swedish identification number and only 5% reported that they always used photo‐ID, the two preferred means for patient identification. Only 12% reported that they always released venous stasis as soon as possible. Fewer PHC staff than clinical laboratory staff reported correct VBS practices. For example, 54% of the PHC staff reported that they always identified the patient by name and Swedish identification number, as compared with 95% of the clinical laboratory staff (P < 0.001). Documented VBS routines and re‐education in VBS were not clearly associated with reported correct VBS practices.Conclusions  In the surveyed PHCs, there are clinically important risks for misidentification of patients and erroneous test results, with consequences for the diagnosis and treatment of patients. Quality interventions, aimed at improving VBS practices, are needed to ensure patient safety.


  • Incident reporting practices in the preanalytical phase: Low reported frequencies in the primary health care setting

    by Johan Söderberg, Kjell Grankvist, Christine Brulin, Olof Wallin

    Objective: Incident reporting is commonly used to improve patient safety. The preanalytical phase of laboratory testing contains several manual error-prone tasks where mistakes can affect patient outcomes. However, the practical use of incident reports in this area has not been previously investigated in the primary health care setting, where the majority of the patients come in contact with health care. Material and methods: All staff responsible for venous blood sampling in 70 primary health care centres and in two hospital clinical laboratories (317 respondents, response rate 94%) completed a questionnaire. Results: Of the primary health care staff, 69% reported that they had never filed an incident report regarding venous blood sampling. Barriers for not filing incident reports often/always included lack of time (44%) and a complicated reporting procedure (27%). A higher proportion of staff with re-education (43%) had filed at least one incident report as compared to those without re-education (20%, p < 0.001). No differences in incident reporting practices were found between primary health care and hospital clinical laboratory staff. Conclusions: The investigated incident reporting system is likely to underreport incidents in the preanalytical phase. Therefore, the ability to discover preventable system vulnerabilities needs refinement.


  • Preanalytical errors in primary healthcare: a questionnaire study of information search procedures, test request management and test tube labelling

    by Johan Söderberg, Christine Brulin, Kjell Grankvist, Olof Wallin

    : Most errors in laboratory medicine occur in the preanalytical phase and are the result of human mistakes. This study investigated information search procedures, test request management and test tube labelling in primary healthcare compared to the same procedures amongst clinical laboratory staff.: A questionnaire was completed by 317 venous blood sampling staff in 70 primary healthcare centres and in two clinical laboratories (response rate = 94%).: Correct procedures were not always followed. Only 60% of the primary healthcare staff reported that they always sought information in the updated, online laboratory manual. Only 12% reported that they always labelled the test tubes prior to drawing blood samples. No major differences between primary healthcare centres and clinical laboratories were found, except for test tube labelling, whereby the laboratory staff reported better practices. Re-education and access to documented routines were not clearly associated with better practices.: The preanalytical procedure in the surveyed primary healthcare centres was associated with a risk of errors which could affect patient safety. To improve patient safety in laboratory testing, all healthcare providers should survey their preanalytical procedures and improve the total testing process with a systems perspective.Clin Chem Lab Med 2009;47:195–201.


  • Haemolysis index – an estimate of preanalytical quality in primary health care

    by Johan Söderberg, P. Andreas Jonsson, Olof Wallin, Kjell Grankvist, Johan Hultdin

    Haemolysis is usually caused by inadequate specimen collection or preanalytical handling, and is suggested to be a suitable indicator of pre-analytical quality. We investigated the prevalence of detectable haemolysis in all routine venous blood samples to identify differences in preanalytical quality. Haemolysis index (HI) values were obtained from a Vitros 5,1 in the routine clinical chemistry laboratory for samples collected in primary health care centres (PHCs), nursing homes, and a hospital emergency department (ED). Haemolysis was defined as a HI > or =15 (detection limit). Samples from the PHC with the highest prevalence of haemolysis were 6.1 times (95% confidence interval (CI) 4.0-9.2) more often haemolysed compared to the centre with the lowest prevalence. Of the samples collected in primary health care, 10.4% were haemolysed compared to 31.1% in the ED (p<0.001). A notable difference in haemolysed samples was found between the ED section staffed by emergency medicine physicians and the section staffed by primary health care physicians (34.8% vs. 11.3%, p<0.001). The significant variation in haemolysis indices among the investigated units is likely to reflect varying preanalytical conditions. The HI is a valuable tool for estimation and follow-up of preanalytical quality in primary health care.