Purpose.: To determine the contribution of evaporation to the thinning of the precorneal tear film between blinks. Methods.: The rate of tear film thinning after a blink was measured using spectral interferometry from the right eyes of 37 subjects. Data were obtained under two different conditions: free air and air-tight goggles. Results.: The mean (±SD) tear film thinning rates for subjects was 3.22 ± 4.27 μm/min in free air and −0.16 ± 1.78 μm/min (i.e., a slight but not significant thickening) for the same subjects wearing air-tight goggles; this reduction in thinning rates was significant (P < 0.0001). Conclusions.: The large reduction in thinning rate caused by wearing goggles indicates that evaporation is the major cause of thinning between blinks. The mean thinning rate in free air is greater than reported evaporation rates; it is argued that the preocular chambers used in evaporimeters restrict movement of air over the tear film and reduce evaporation compared to our free air condition.Keywords
This publication has 24 references indexed in Scilit:
- Application of a Novel Interferometric Method to Investigate the Relation between Lipid Layer Thickness and Tear Film ThinningInvestigative Ophthalmology & Visual Science, 2010
- The Contribution of Lipid Layer Movement to Tear Film Thinning and BreakupInvestigative Ophthalmology & Visual Science, 2009
- Closed‐chamber transepidermal water loss measurement: microclimate, calibration and performanceInternational Journal of Cosmetic Science, 2009
- Contributions of Evaporation and Other Mechanisms to Tear Film Thinning and Break‐UpOptometry and Vision Science, 2008
- Thinning Rate of the Precorneal and Prelens Tear FilmsInvestigative Ophthalmology & Visual Science, 2005
- Ocular Surface TemperatureEye & Contact Lens: Science & Clinical Practice, 2005
- Aquaporin-Dependent Water Permeation at the Mouse Ocular Surface: In Vivo Microfluorimetric Measurements in Cornea and ConjunctivaInvestigative Ophthalmology & Visual Science, 2004
- Correlation of lipid layer thickness measurements with fluorescein tear film break-up time and Schirmer's testEye, 2003
- Importance of the Lipid Layer in Human Tear Film Stability and EvaporationOptometry and Vision Science, 1997
- A non-invasive instrument for clinical assessment of the pre-corneal tear film stabilityCurrent Eye Research, 1985