Localization of Origins of Premature Ventricular Contraction by Means of Convolutional Neural Network From 12-Lead ECG
- 26 September 2017
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 65 (7) , 1662-1671
Abstract
Objective: This paper proposes a novel method to localize origins of premature ventricular contractions (PVCs) from 12-lead electrocardiography (ECG) using convolutional neural network (CNN) and a realistic computer heart model. Methods: The proposed method consists of two CNNs (Segment CNN and Epi-Endo CNN) to classify among ventricular sources from 25 segments and from epicardium (Epi) or endocardium (Endo). The inputs are the full time courses and the first half of QRS complexes of 12-lead ECG, respectively. After registering the ventricle computer model with an individual patient's heart, the training datasets were generated by multiplying ventricular current dipoles derived from single pacing at various locations with patient-specific lead field. The origins of PVC are localized by calculating the weighted center of gravity of classification returned by the CNNs. A number of computer simulations were conducted to evaluate the proposed method under a variety of noise levels and heart registration errors. Furthermore, the proposed method was evaluated on 90 PVC beats from nine human patients with PVCs and compared against ablation outcome in the same patients. Results: The computer simulation evaluation returned relatively high accuracies for Segment CNN (~78%) and Epi-Endo CNN (~90%). Clinical testing in nine PVC patients resulted an averaged localization error of 11 mm. Conclusion: Our simulation and clinical evaluation results demonstrate the capability and merits of the proposed CNN-based method for localization of PVC. Significance: This paper suggests a new approach for cardiac source localization of origin of arrhythmias using only the 12-lead ECG by means of CNN, and may have important applications for future real-time monitoring and localizing origins of cardiac arrhythmias guiding ablation treatment.Keywords
Funding Information
- National Institutes of Health (HL080093)
- National Science Foundation (CBET-0756331)
- Chinese “111 Project” (B08020)
This publication has 44 references indexed in Scilit:
- Image-Based Biophysical Simulation of Intracardiac Abnormal Ventricular ElectrogramsIEEE Transactions on Biomedical Engineering, 2016
- Influence of Modeling Errors on the Initial Estimate for Nonlinear Myocardial Activation Times Imaging Calculated With Fastest Route AlgorithmIEEE Transactions on Biomedical Engineering, 2016
- Temporal Sparse Promoting Three Dimensional Imaging of Cardiac ActivationIEEE Transactions on Medical Imaging, 2015
- Quantitative localization of premature ventricular contractions using myocardial activation ECGI from the standard 12-lead electrocardiogramJournal of Electrocardiology, 2013
- Noninvasive cardiac activation imaging of ventricular arrhythmias during drug-induced QT prolongation in the rabbit heartHeart Rhythm, 2013
- Noninvasive reconstruction of the three-dimensional ventricular activation sequence during pacing and ventricular tachycardia in the canine heartAmerican Journal of Physiology-Heart and Circulatory Physiology, 2012
- Noninvasive imaging of three-dimensional cardiac activation sequence during pacing and ventricular tachycardiaHeart Rhythm, 2011
- Application of the fastest route algorithm in the interactive simulation of the effect of local ischemia on the ECGMedical & Biological Engineering & Computing, 2008
- Noninvasive reconstruction of three-dimensional ventricular activation sequence from the inverse solution of distributed equivalent current densityIEEE Transactions on Medical Imaging, 2006
- Electrocardiographic Recognition of the Epicardial Origin of Ventricular TachycardiasCirculation, 2004