Comparison of red blood cell survival in sheep determined using red blood cells labeled with either biotin at multiple densities or [14C]cyanate: validation of a model to study human physiology and disease
- 9 January 2012
- journal article
- research article
- Published by Wiley in Transfusion
- Vol. 52 (5) , 963-973
Abstract
BACKGROUND: Measurement of red blood cell (RBC) survival (RCS) is important for investigating pathophysiology and treatment of anemia. Our objective was to validate the multidensity biotin method for RCS determination in sheep, a commonly used model of RBC physiology. [14C]Cyanate served as the reference method for long‐term RCS because the 51Cr method (the reference method for humans) is not reliable in sheep.STUDY DESIGN AND METHODS: Aliquots of autologous RBCs from eight adult sheep were labeled with [14C]cyanate and four separate densities of biotin (BioRBCs) and reinfused. Short‐term RCS was assessed by posttransfusion recovery at 24 hours (PTR24); long‐term RCS was assessed by the time to 50% survival (T50) and mean potential life span (MPL).RESULTS: Values for PTR24 of the four BioRBC densities were not different. Values for RCS as reflected by T50 and MPL were nearly identical for [14C]cyanate and the two intermediate‐density BioRBC populations. In contrast, the lowest‐density BioRBC population survived slightly longer (p < 0.01), but with a difference of no clinical significance. The highest‐density BioRBC population importantly shortened RCS (p < 0.01 compared to the two intermediate densities).CONCLUSION: This study provides evidence that BioRBCs labeled at four biotin densities can be used to independently and simultaneously measure short‐term RCS and that BioRBCs labeled at the three lowest biotin densities can be used to accurately and simultaneously measure long‐term RCS. Because the sheep RBC model is comparable to humans, this nonradioactive method has promise for use in RBC kinetic studies in neonates and pregnant women.Keywords
This publication has 29 references indexed in Scilit:
- Red blood cell (RBC) volume can be independently determined in vivo in humans using RBCs labeled at different densities of biotinTransfusion, 2011
- Red blood cell (RBC) volume can be independently determined in vivo in the sheep using ovine RBCs labeled at different densities of biotinTransfusion, 2010
- Red blood cell (RBC) survival determined in humans using RBCs labeled at multiple biotin densitiesTransfusion, 2010
- Red blood cell volume can be independently determined in vitro using sheep and human red blood cells labeled at different densities of biotinTransfusion, 2009
- The measurement and importance of red cell survivalAmerican Journal of Hematology, 2008
- Red Cell Volume Can Be Accurately Determined in Sheep Using a Nonradioactive Biotin LabelPediatric Research, 2008
- Biotin labeling as an alternative nonradioactive approach to determination of red cell survivalAnnals of Hematology, 1993
- Elution Correction in 51Cr Red Cell Survival StudiesBritish Journal of Haematology, 1974
- Factors Influencing Chromium Elution from Labelled Red Cells in Vivo and the Effect of Elution on Red‐Cell Survival MeasurementsBritish Journal of Haematology, 1970
- THE USE OF RADIOACTIVE CHROMIUM 51 AS AN ERYTHROCYTE TAGGING AGENT FOR THE DETERMINATION OF RED CELL SURVIVAL IN VIVO 12Journal of Clinical Investigation, 1953