1.7 micron optical coherence tomography for vaginal tissue characterization in vivo
- 30 July 2018
- journal article
- research article
- Published by Wiley in Lasers in Surgery and Medicine
- Vol. 51 (2) , 120-126
Abstract
Objectives: Optical coherence tomography (OCT) can noninvasively visualize in vivo tissue microstructure with high spatial resolution that approaches the histologic level. Currently, OCT studies in gynecology are few and limited to a conventional 1.3 μm center wavelength swept light source which provides high spatial resolution but limited penetration depth. Here, we present a novel endoscopic OCT system with improved penetration depth and high resolution.Methods: A novel endoscopic OCT system was developed based on a 1.7 µm swept source laser, which is capable of deeper tissue penetration due to its longer wavelength. To evaluate the performance of system, we imaged the human vaginas in vivo with both conventional 1.3 and 1.7 μm endoscopic OCT systems.Results: With the 1.7 μm endoscopic OCT system, imaging depth was improved by more than 25%, allowing better visualization of the lamina propria and clear contrast of the epithelial layer from the surrounding tissues.Conclusion: The significantly improved performance of the novel 1.7 μm OCT imaging system demonstrates its potential use as a minimally‐invasive monitoring tool of vaginal health in gynecologic practice. Lasers Surg. Med. 51:120–126, 2019.Keywords
Funding Information
- National Institutes of Health (R01HL‐125084, R01HL‐127271, R01EY‐026091, R01EY‐02, R01EY‐021529, P41EB‐015890)
- Air Force Office of Scientific Research (FA9550‐17‐1‐0193)
This publication has 21 references indexed in Scilit:
- Intravascular Optical Coherence Tomography for Characterization of Atherosclerosis with a 1.7 Micron Swept-Source LaserScientific Reports, 2017
- Fully integrated optical coherence tomography, ultrasound, and indocyanine green-based fluorescence tri-modality system for intravascular imagingBiomedical Optics Express, 2017
- High-speed intravascular spectroscopic photoacoustic imaging at 1000 A-lines per second with a 0.9-mm diameter catheterJournal of Biomedical Optics, 2015
- Genitourinary syndrome of menopauseMenopause, 2014
- Assessment of vaginal atrophy: a reviewInternational Urogynecology Journal, 2014
- The Structure of the Human VaginalStratum Corneumand its Role in Immune DefenseAmerican Journal of Reproductive Immunology, 2014
- Histology of the vaginal wall in women with pelvic organ prolapse: a literature reviewInternational Urogynecology Journal, 2013
- Vulvovaginal AtrophyMayo Clinic Proceedings, 2010
- The effect of oestradiol on vaginal collagen metabolism in postmenopausal women with genuine stress incontinenceBJOG: An International Journal of Obstetrics & Gynaecology, 2002
- Noninvasive imaging of in vivo blood flow velocity using optical Doppler tomographyOptics Letters, 1997