Head‐and‐neck multichannel B1+ mapping and RF shimming of the carotid arteries using a 7T parallel‐transmit head coil
Open Access
- 5 October 2023
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 91 (1) , 190-204
Abstract
Purpose: Neurovascular MRI suffers from a rapid drop in B1+ into the neck when using transmit head coils at 7 T. One solution to improving B1+ magnitude in the major feeding arteries in the neck is to use custom RF shims on parallel‐transmit head coils. However, calculating such shims requires robust multichannel B1+ maps in both the head and the neck, which is challenging due to low RF penetration into the neck, limited dynamic range of multichannel B1+ mapping techniques, and B0 sensitivity. We therefore sought a robust, large‐dynamic‐range, parallel‐transmit field mapping protocol and tested whether RF shimming can improve carotid artery B1+ magnitude in practice.Methods: A pipeline is presented that combines B1+ mapping data acquired using circularly polarized (CP) and CP2‐mode RF shims at multiple voltages. The pipeline was evaluated by comparing the predicted and measured B1+ for multiple random transmit shims, and by assessing the ability of RF shimming to increase B1+ in the carotid arteries.Results: The proposed method achieved good agreement between predicted and measured B1+ in both the head and the neck. The B1+ magnitude in the carotid arteries can be increased by 43% using tailored RF shims or by 37% using universal RF shims, while also improving the RF homogeneity compared with CP mode.Conclusion: B1+ in the neck can be increased using RF shims calculated from multichannel B1+ maps in both the head and the neck. This can be achieved using universal phase‐only RF shims, facilitating easy implementation in existing sequences.Keywords
Funding Information
- Vivensa Foundation
- Engineering and Physical Sciences Research Council
- NIHR Oxford Biomedical Research Centre
- Siemens Healthineers
- Wellcome Trust (203139/Z/16/Z)
This publication has 22 references indexed in Scilit:
- The effect of patient age on the internal carotid artery location around the atlasJournal of Neurosurgery: Spine, 2010
- Arterial spin labeling at ultra‐high field: All that glitters is not goldInternational Journal of Imaging Systems and Technology, 2010
- Broadband slab selection with B mitigation at 7T via parallel spectral‐spatial excitationMagnetic Resonance in Medicine, 2009
- A geometrically adjustable 16‐channel transmit/receive transmission line array for improved RF efficiency and parallel imaging performance at 7 TeslaMagnetic Resonance in Medicine, 2008
- Exploring the limits of RF shimming for high‐field MRI of the human headMagnetic Resonance in Medicine, 2006
- Manipulation of image intensity distribution at 7.0 T: Passive RF shimming and focusing with dielectric materialsJournal of Magnetic Resonance Imaging, 2006
- B1 destructive interferences and spatial phase patterns at 7 T with a head transceiver array coilMagnetic Resonance in Medicine, 2005
- Parallel excitation with an array of transmit coilsMagnetic Resonance in Medicine, 2004
- Fast, automated, N‐dimensional phase‐unwrapping algorithmMagnetic Resonance in Medicine, 2002
- Transmit SENSEMagnetic Resonance in Medicine, 2002