The NICE recommendation for drug-coated balloons and its global impact
Open Access
- 2 March 2015
- journal article
- review article
- Published by SAGE Publications in Therapeutic Advances in Cardiovascular Disease
- Vol. 9 (3) , 87-94
Abstract
The clinical efficacy and safety of drug-coated balloon (DCB) angioplasty in patients with coronary in-stent restenosis (ISR) has been demonstrated. The objective of this article is to provide comparative cost efficacy data for DCB angioplasty in various countries based on the original methodology of the Medical Technologies Evaluation Programme (MTEP) at the National Institute for Health and Clinical Excellence (NICE) in 2010. Published and unpublished Health Technology Assessment (HTA) reports were evaluated for comparison in selected countries. Furthermore, a systematic review of economic evaluations of DCB angioplasty versus standard treatments (uncoated balloon angioplasty or drug-eluting stent implantations) was conducted. National cost efficacy data were evaluated using Markov state transition models which were adapted to fit each country’s device and procedure related costs. The clinical input for adverse events was defined with two relevant trials for in-stent restenosis of bare metal stents (BMS-ISR) and of drug-eluting stents (DES-ISR). In the UK, Germany, Switzerland, South Africa, Japan and Brazil, DCB angioplasty is cost-effective when compared with drug-eluting stents to treat either BMS-ISR or DES-ISR. DCB angioplasty ought to be the preferred treatment option for patients with BMS-ISR and DES-ISR from the payers’ point of view.Keywords
This publication has 27 references indexed in Scilit:
- A Randomized Comparison of Drug-Eluting Balloon Versus Everolimus-Eluting Stent in Patients With Bare-Metal Stent–In-Stent RestenosisJACC, 2014
- Cost-Effectiveness Analysis of Paclitaxel-Coated Balloons for Endovascular Therapy of Femoropopliteal Arterial ObstructionsJournal of Endovascular Therapy, 2013
- The Paclitaxel-eluting PTCA-balloon in combination with a cobalt-chromium stent in two different sequences to treat de novo coronary artery lesions: An angiographic follow up studyIndian Heart Journal, 2013
- A multicenter randomized comparison of paclitaxel-coated balloon catheter with conventional balloon angioplasty in patients with bare-metal stent restenosis and drug-eluting stent restenosisAmerican Heart Journal, 2013
- Cost‐Effectiveness of Paclitaxel‐Coated Balloon Angioplasty in Patients With Drug‐Eluting Stent RestenosisClinical Cardiology, 2013
- Paclitaxel-eluting balloons, paclitaxel-eluting stents, and balloon angioplasty in patients with restenosis after implantation of a drug-eluting stent (ISAR-DESIRE 3): a randomised, open-label trialThe Lancet, 2013
- Cost-effectiveness of paclitaxel-coated balloon angioplasty and paclitaxel-eluting stent implantation for treatment of coronary in-stent restenosis in patients with stable coronary artery diseaseClinical Research in Cardiology, 2012
- Paclitaxel-eluting balloon angioplasty and cobalt-chromium stents versus conventional angioplasty and paclitaxel-eluting stents in the treatment of native coronary artery stenoses in patients with diabetes mellitusEuroIntervention, 2011
- Effectiveness of Paclitaxel-Eluting Balloon Catheter in Patients With Sirolimus-Eluting Stent RestenosisJACC: Cardiovascular Interventions, 2011
- Paclitaxel-coated balloon versus drug-eluting stent during PCI of small coronary vessels, a prospective randomised clinical trial. The PICCOLETO StudyHeart, 2010