Optical Sensor for Sulfur Dioxide Determination in Wines
- 14 October 2006
- journal article
- research article
- Published by American Chemical Society (ACS) in Journal of Agricultural and Food Chemistry
- Vol. 54 (23) , 8697-8701
Abstract
A method for the determination of free and total sulfur dioxide in wines, based on the use of an optical sensor that employs a dichlorobis(diphenylphosphino)methane dipalladium I complex [Pd2(dppm)2Cl2] immobilized in a PVC membrane plasticized with o-nitrophenyloctylether (o-NPOE) is described. A sensing membrane [4.2% Pd2(dppm)2Cl2, 20.8% PVC, and 75% o-NPOE] was adapted to the tip of a bifurcated optical fiber bundle to perform reflectance measurements at 550 nm. The detection system consisted of two cells (40 mL), which hold the sample solution (plus reagents) and the optical sensor, respectively. For the determination of free SO2, a wine sample was mixed with H2SO4 solution in the sample cell, into which N2 was bubbled, providing mixing of the solutions and conducting the SO2 formed toward the detection cell. For determination of total SO2, a KOH solution was mixed with the wine in the sample cell. Afterward, an H2SO4 solution was added to the cell, and then N2 was bubbled to conclude the measurement. Linear responses up to 50 and 150 mg L-1 were obtained for free and total SO2, with detection limits of 0.37 and 0.70 mg L-1, respectively. The repeatability of the method was evaluated by carrying out 10 measurements using a single wine sample, providing relative standard deviation values of 2.2 and 2.5% for free and total SO2, respectively. The sensing membrane prepared from 10 μL of the cocktail solution lasted for 80 measurements, whereas those prepared from 200 μL can be used for 250 measurements. The method was applied to free and total SO2 determination in wines, and the results did not show significant difference from those obtained with the Ripper reference method at a confidence level of 95%. Keywords: Optical sensor; gas sensor; sulfur dioxide; sulfite; wineKeywords
This publication has 12 references indexed in Scilit:
- Determination of free and total sulfur dioxide in wine samples by vapour-generation inductively coupled plasma–optical-emission spectrometryAnalytical and Bioanalytical Chemistry, 2005
- An organopalladium-PVC membrane for sulphur dioxide optical sensingSensors and Actuators B: Chemical, 2005
- Determination of free and total sulphur dioxide in wine by use of an amalgamated piezoelectric sensorAnalytica Chimica Acta, 2005
- A multichannel photometer based on an array of light emitting diodes for use in multivariate calibrationAnalytica Chimica Acta, 2004
- Reagentless system for sulphite determination based on polyanilineAnalytica Chimica Acta, 2004
- A gas diffusion sequential injection system for the determination of sulphur dioxide in winesAnalytica Chimica Acta, 2001
- Evaluation of Nafion–Crystal Violet films for the construction of an optical relative humidity sensorThe Analyst, 1999
- Optical sensing of sulfite with a phosphorescent probeAnalytica Chimica Acta, 1998
- Determination of sulphur and total sulphur dioxide in wines by an ICP-AES methodTalanta, 1998
- Determination of SO2 in Wines Using a Flow Injection Analysis System with Potentiometric DetectionJournal of Agricultural and Food Chemistry, 1998