A virtual SIC: A new way of diagnosing occupational asthma in the COVID-19 pandemic

Authors:

Abstract
We present a novel way of performing a specific inhalation challenge test (SIC) for the diagnosis of occupational asthma. During the COVID 19 pandemic, it has not been possible to admit patients, therefore we performed it virtually. The worker was a 32 year old physiotherapist who started to have problems related to wearing FFP3 or surgical masks introduced at the advent of COVID-19. Methods: The worker completed virtually supervised FEV1 and PEF measurements (using the Vitalograph Asma-1), then went to a separate room where she wore one of the masks; Day 1: surgical mask for 1.5 hours; day 2 surgical mask for 3 hours; day 3 – rest day; day 4 FFP3 for 3 hours. She performed hourly readings until bed (supervised during working hours). The following week, she wore the surgical mask Monday-Friday during working hours performing hourly FEV1/PEF. After an 8 week break, an airfed helmet was tested in the same way for a week. Results: The hoarse voice and tingling tongue started within 1 hour of wearing the surgical and FFP3 masks. She developed chest tightness in the afternoon. She had no change in her FEV1 and no facial swelling or rash during days 1-4. After day 5, her face swelled and the rash appeared, but her FEV1 remained stable. This continued for a further 2 weeks and took approximately 8 weeks to get back to normal. The airfed helmet produced no symptoms or FEV1 change. Conclusion: Remote SICs are possible although caution would need to be taken with the agents used. The cause of the cases’ symptoms is still being investigated but could be associated with the waterproofing material.