VMVicky C. Moore

Vicky C. Moore

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Vicky C. Moore has a total of 37 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Work-related asthma in stainless steel welders, irritant or allergy?

    by Vicky C Moore, Alastair S Robertson, Christopher C Huntley, Gareth I Walters, P Sherwood Burge

    Background: Work-related asthma in welders is often thought to be irritant rather than allergic, limiting the availability of surveillance, assisted retraining and compensation. However, excess inflammatory gene activation is a feature of asthma in stainless-steel welders. Aims: To investigate a cohort of workers exposed to stainless-steel welding fume who have work-related symptoms to assess if their diagnosis best fits irritant or allergic phenotypes or endotypes. Methods: All workers seen between 2000 and 2021 with confirmed work-related asthma exposed to stainless-steel welding fume were included. The types of exposure responses were identified from Oasys programme plots of 2-hourly peak expiratory flow (PEF) measurements at work and home over 4 weeks. While exposed, non-specific bronchial reactivity (NSBR), atopy, eosinophilia and fractional exhaled nitric oxide (FeNO) were measured. The irritant endotype was defined as (i) absence of relevant immunoglobulin E sensitization; (ii) association with NSBR; (iii) immediate onset of symptoms following exposure; and (iv) either pre-existing asthma or a latency period for symptom onset of <6 months. Results: Twenty-five workers exposed to stainless-steel welding fume showed PEF changes, confirming work-related asthma. A possible irritant endotype was present in four. One had pre-existing asthma, two had latencies of <6 months and three had NSBR. Peripheral eosinophilia and raised FeNO were uncommon. Conclusions: The phenotype or endotype was incompatible with purely irritant mechanisms in 21 participants and had predominately T helper 2 low inflammatory characteristics. Stainless-steel welders with work-related asthma should be managed as occupational asthma with hypersensitivity.

  • Stay home; save lives; aid the diagnosis of occupational asthma

    by Vicky Moore, Sherwood Burge, Christopher Huntley, Alastair Robertson, Gareth Walters

    Introduction: Many UK workers have had paid, extended periods away from work due to the COVID-19 pandemic. In those with suspected occupational asthma (OA) this has enabled assessment of serial peak expiratory flow (PEF) over long periods away from their workplace. Methods: Those who had been followed up by telephone or face-to-face between March and December 2020, had completed serial PEF measurements while at work (pre-March 2020), and then during a long period away from work were included. Workers were asked to complete 4 weeks of readings taking them every 2 hours from waking to sleeping each day, whether in the workplace or not. Data was analysed using the OASYS software program. Results: 10 patients completed serial PEF measurements during the time periods specified. 7 workers showed an improvement in their mean PEFs with prolonged time away from work. Table 1 shows the results. Conclusion: Although the diagnosis of OA is usually based on analysis of serial PEFs performed during short, alternating episodes at and away from work, PEFs recorded during longer periods away from the workplace have provided evidence of OA in some patients with equivocal PEF results beforehand and confirmed OA in others.

  • A virtual SIC: A new way of diagnosing occupational asthma in the COVID-19 pandemic

    by Vicky Moore, Sherwood Burge, Christopher Huntley, Alastair Robertson, Gareth Walters

    We present a novel way of performing a specific inhalation challenge test (SIC) for the diagnosis of occupational asthma. During the COVID 19 pandemic, it has not been possible to admit patients, therefore we performed it virtually. The worker was a 32 year old physiotherapist who started to have problems related to wearing FFP3 or surgical masks introduced at the advent of COVID-19. Methods: The worker completed virtually supervised FEV1 and PEF measurements (using the Vitalograph Asma-1), then went to a separate room where she wore one of the masks; Day 1: surgical mask for 1.5 hours; day 2 surgical mask for 3 hours; day 3 – rest day; day 4 FFP3 for 3 hours. She performed hourly readings until bed (supervised during working hours). The following week, she wore the surgical mask Monday-Friday during working hours performing hourly FEV1/PEF. After an 8 week break, an airfed helmet was tested in the same way for a week. Results: The hoarse voice and tingling tongue started within 1 hour of wearing the surgical and FFP3 masks. She developed chest tightness in the afternoon. She had no change in her FEV1 and no facial swelling or rash during days 1-4. After day 5, her face swelled and the rash appeared, but her FEV1 remained stable. This continued for a further 2 weeks and took approximately 8 weeks to get back to normal. The airfed helmet produced no symptoms or FEV1 change. Conclusion: Remote SICs are possible although caution would need to be taken with the agents used. The cause of the cases’ symptoms is still being investigated but could be associated with the waterproofing material.

  • Around the world usage of the Oasys serial PEF plotter for the diagnosis of occupational asthma

    by Vicky Moore, Cedd Burge, Gareth Walters, Alastair Robertson, Sherwood Burge

    The Oasys plotter is the best validated method of analysing serial PEF measurements in the diagnosis of occupational asthma, and is supported by all evidence-based reviews. In April 2010 it became freely available via www.occupationalasthma.com to which anonymous records can be uploaded and reports generated. The website includes the email address of the uploader, from which the country or origin can often be identified. We have analysed the internet usage of Oasys by country of origin over the last 10 years, and identified records that reach diagnostic quality of at least 1 Oasys score. Results: 6,530 records were uploaded, the country of origin was identifiable in 67%.There has been an average of 266 records entered per year in the UK, 175 from other identified countries and 212 from country non-specific addresses (such as .com). Overall, over half of the records achieved optimal diagnostic quality (Table 1). Figure 1 shows the number of diagnostic quality PEFs plotted by country. Conclusion: Serial PEF records are achievable around the world and using a program such as Oasys can give diagnostic quality results.

  • Specific inhalation challenges with chloramines; an updated method

    by Vicky Moore, Gareth Walters, Alastair Robertson, Maximillian Thomas, Sherwood Burge

    Occupational asthma (OA) caused by chlorine has been previously reported. However, we have often been unable to reproduce asthma following specific inhalation challenge (SIC) using chlorine-based agents. This could be due to the actual cause of symptoms being the chloramines produced from the reaction of chlorinated water with a nitrogen source. Initial SICs used nitrogen trichloride but had safety issues. We then reported a positive SIC after adding 5 ml urine to 100 ml of 10,000 ppm chlorine solution generating volatile chloramines. This followed a negative SIC with chlorine in aqueous solution in a nurse with good evidence of occupational asthma. We aimed to further improve this method. Methods: 5 healthcare or swimming pool workers underwent SIC to chloramines created by adding up to 1g of urea powder to 100 ml of 10,000 ppm chlorine solution painted onto cardboard. The chlorine solution alone was used as a control. Results: 3 workers had a positive SIC (a late reaction - Figure 1; an immediate reaction; and a > 10 fold increase in methacholine hyperreactivity). The 2 negative challenges were in a swimming teacher who hadn’t been exposed for 3 years and a healthcare worker who had a number of other possible causes. Conclusion: Chloramines can cause OA in healthcare workers, cleaners and swimming pool workers. It is possible to perform a chloramine SIC in a safe, repeatable and simple way using urea powder mixed with chlorine solution.

  • Diagnosis of occupational asthma from serial measurements of forced expiratory volume in 1 s (FEV1) using the Area Between Curves (ABC) score from the Oasys plotter

    by Edward D Parkes, Vicky C Moore, Gareth I Walters, Peter Sherwood Burge

    Objectives: To identify the changes in serial 2-hourly forced expiratory volume in 1 s (FEV1) measurements required to identify occupational asthma (OA) using the Oasys Area Between Curves (ABC) score.Methods: The ABC score from 2-hourly measurements of FEV1was compared between workers with confirmed OA and asthmatics without occupational exposure to identify the optimum separation using receiver operator characteristic (ROC) analysis. Separate analyses were made for plots using clock time and time from waking to allow for use in shift workers. Minimum record criteria were ≥6 readings per day, >4 day shifts and >4 rest days (or >9 days for controls).Results: A retrospective analysis identified 22 workers with OA and 30 control asthmatics whose records reached the quality standards. Median FEV1diurnal variation was 20.3% (IQR 16.1–32.6) for OA and 19.5% (IQR 14.5–26.1) for asthmatic controls. ROC curve analysis identified that a difference of 0.056 L/hour gave a ROC score of 0.821 for clock time and 0.768 for time from waking with a sensitivity of 73% and a specificity of 93% for the diagnosis of OA.Conclusions: The diagnosis of OA requires objective confirmation. Unsupervised serial FEV1measurements are more difficult to obtain reliably than measurements of peak expiratory flow, which are likely to remain the standard for general use. A FEV1ABC score >0.056 L/hour provides a valid cut-off for those who wish to use FEV1rather than peak expiratory flow.


  • Identification of late asthmatic reactions following specific inhalation challenge

    by Vicky C Moore, Gareth Iestyn Walters, Alastair S Robertson, P Sherwood Burge

    Specific inhalation challenge (SIC) is the reference standard for the diagnosis of occupational asthma. Current guidelines for identifying late asthmatic reactions are not evidence based.Objectives: To identify the fall in forced expiratory volume in 1 s (FEV1) required following SIC to exceed the 95% CI for control days, factors which influence this and to show how this can be applied in routine practice using a statistical method based on the pooled SD for FEV1from three control days.Methods: Fifty consecutive workers being investigated for occupational asthma were asked to self-record FEV1hourly for 2 days before admission for SIC. These 2 days were added to the in-hospital control day to calculate the pooled SD and 95% CI.Results: 45/50 kept adequate measurements. The pooled 95% CI was 385 mL (SD 126), or 14.2% (SD 6.2) of the baseline FEV1, but was unrelated to the baseline FEV1(r=0.06, p=0.68), or gender, atopy, smoking, non-specific reactivity or treatment before or during SIC. Thirteen workers had a late asthmatic reaction with ≥2 consecutive FEV1measurements below the 95% CI for pooled control days, 4/13 had 15% late fall from baseline. The four workers with ≥2 values below the 95% CI all had independent evidence of occupational asthma.Conclusion: The pooled SD method for defining late asthmatic reactions has scientific validity, accounts for interpatient spirometric variability and diurnal variation and can identify clinically relevant late asthmatic reactions from smaller exposures. For baseline FEV1<2.5 L, a 15% fall is within the 95% CI.

  • Identification of late asthmatic reactions following specific inhalation challenge

    by Vicky Moore, Gareth Walters, Alastair Robertson, Sherwood Burge

    Background: Specific inhalation tests (SIC) aim to identify the specific cause of asthma with sufficient certainty to exclude measurement inaccuracy and spontaneous diurnal changes, while minimising deterioration in the workers asthma. We aimed to define late asthmatic reactions using the pooled SD method of Stenton in consecutive workers undergoing SIC. Methods: Two unsupervised control days at home were added to an in-hospital control day to provide the three control days required to calculate the pooled FEV1 SD. A late asthmatic reaction required two consecutive measurements below the 95% CI for the control days. The absolute change in ml and the change expressed as % baseline were calculated. Results: Sufficient FEV1 data were provided by 45/50 workers. The mean 95% CI for control day FEV1 was 385ml (SD 126), independent of FEV1, treatment and personal characteristics. Four workers had late asthmatic reactions identified only by the pooled SD method, all confirmed by independent methods. The 95% CI for the FEV1 fall expressed as a percent baseline value was 14.2% (SD 6.2%), correlated inversely with the baseline FEV1 (r=0.55, p<0.0001 Figure 1). Conclusions: The pooled standard deviation method for defining late asthmatic reactions has scientific validity, accounts for inter-patient spirometric variability and diurnal variation, and can identify clinically relevant late asthmatic reactions from smaller exposures. It warrants inclusion in guidelines.


  • Open Access

    Shift work effects on serial PEF measurements for occupational asthma

    by V. C. Moore, M. S. Jaakkola, C. B. S. G. Burge, C. F. A. Pantin, A. S. Robertson, P. S. Burge

    Diurnal variation (DV) affects lung function but the changes are thought to be related to sleep patterns rather than time of day. When diagnosing occupational asthma (OA), serial peak expiratory flow (PEF) measurements are the recommended first line investigation, but could be confounded by shift work. The aim of the study was to investigate the effects of shift work on PEF measurements used for diagnosing OA. PEF records containing more than one shift pattern with ≥4 days per shift were identified. OA diagnosis was based on an Oasys-2 score ≥2.51 and non-OA on having an alternative clinical diagnosis and Oasys-2 score P < 0.001). The ABC score was lower in the OA group on night (P < 0.05) and afternoon shifts (P < 0.05) as compared with days, without significant differences in DV. Among those without OA, cross-shift PEF increased more on day shifts (mean + 25 l/min) than afternoon or night shifts (+1 l/min) (P < 0.001). The sensitivity for the ABC score and DV were good and similar across shifts, but specificity was reduced using DV (DV mean 39%; ABC 98%). PEF responses between work and rest show small differences according to shift type. The ABC score has a high sensitivity and specificity for all shifts; differences in DV have lower specificity.