Real-time monitoring of extracellular pH using a pH-potentiometric sensing SECM dual-microelectrode
- 3 May 2020
- journal article
- research article
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 412 (15) , 3737-3743
Abstract
Extracellular pH can indicate the variation in organelle function and cell state. It is important to measure extracellular pH (pHe) with a controllable distance. In this work, a potentiometric SECM dual-microelectrode was developed to monitor the pHe of MCF-7 cells under electrical stimulation. The distance between the dual-microelectrode and the cells was determined first with a gold microelectrode by recording the approaching curve, and the pH was determined using an open-circuit potential (OCP) technique with a polyaniline-modified Pt microelectrode. The pH microelectrode showed a response slope of 53.0 ± 0.4 mV/pH and good reversibility from pH 4 to pH 8, fast response within 10 s, and a potential drift of 1.13% for 3 h, and thus was employed to monitor the pHe of stimulated cells. The value of pHe decreased with the decrease in the distance to cells, likely due to the release of H+. With an increase in the stimulation potential or time, the pHe value decreased, as the cell membrane became more permeable, which was verified by fluorescence staining of calcein-AM/PI (propidium iodide). Based on these results, this method can be widely applied for determining the species released by biosystems at a controllable position.Keywords
Funding Information
- National Natural Science Foundation of China (No. 21575042)
This publication has 44 references indexed in Scilit:
- Monitoring Ion Activities In and Around Cells Using Ion-Selective Liquid-Membrane MicroelectrodesSensors, 2013
- Tattoo-based potentiometric ion-selective sensors for epidermal pH monitoringThe Analyst, 2012
- The a3 Isoform Vacuolar Type H+-ATPase Promotes Distant Metastasis in the Mouse B16 Melanoma CellsMolecular Cancer Research, 2011
- Using silicon nanowire devices to detect adenosine triphosphate liberated from electrically stimulated HeLa cellsBiosensors and Bioelectronics, 2011
- Serial In vivo Spectroscopic Nuclear Magnetic Resonance Imaging of Lactate and Extracellular pH in Rat Gliomas Shows Redistribution of Protons Away from Sites of GlycolysisCancer Research, 2007
- All-Optical Nanoscale pH MeterNano Letters, 2006
- Hypoxia activates the capacity of tumor‐associated carbonic anhydrase IX to acidify extracellular pHFEBS Letters, 2004
- Solid-state pH nanoelectrode based on polyaniline thin film electrodeposited onto ion-beam etched carbon fiberAnalytica Chimica Acta, 2002
- Molecular and functional characterization of sodium–hydrogen exchanger in skin as well as cultured keratinocytes and melanocytesBiochimica et Biophysica Acta (BBA) - Biomembranes, 2001
- Novel polypyrrole based all-solid-state potassium-selective microelectrodesThe Analyst, 1998