Ranran Song
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Ranran Song has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Fan Zhang
School of Chemistry and Molecular Engineering, East China Normal University, 500 Dongchuan Road, Shanghai, 200241, PR China
1 shared publication Guancheng Jiang
1 shared publication- Guancheng Jiang
College of Petroleum Engineering China University of Petroleum Beijing 102249 China
1 shared publication Guanggang Zhou
1 shared publicationGuiwu Lu
1 shared publicationKai Wang
College of Petroleum Engineering China University of Petroleum Beijing 102249 China
1 shared publication
Latest Publications
- 3 May 2020
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 412 (15) , 3737-3743
Real-time monitoring of extracellular pH using a pH-potentiometric sensing SECM dual-microelectrode
Extracellular pH can indicate the variation in organelle function and cell state. It is important to measure extracellular pH (pHe) with a controllable distance. In this work, a potentiometric SECM dual-microelectrode was developed to monitor the pHe of MCF-7 cells under electrical stimulation. The distance between the dual-microelectrode and the cells was determined first with a gold microelectrode by recording the approaching curve, and the pH was determined using an open-circuit potential (OCP) technique with a polyaniline-modified Pt microelectrode. The pH microelectrode showed a response slope of 53.0 ± 0.4 mV/pH and good reversibility from pH 4 to pH 8, fast response within 10 s, and a potential drift of 1.13% for 3 h, and thus was employed to monitor the pHe of stimulated cells. The value of pHe decreased with the decrease in the distance to cells, likely due to the release of H+. With an increase in the stimulation potential or time, the pHe value decreased, as the cell membrane became more permeable, which was verified by fluorescence staining of calcein-AM/PI (propidium iodide). Based on these results, this method can be widely applied for determining the species released by biosystems at a controllable position.
- 3 May 2020
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 412 (15) , 3737-3743
Real-time monitoring of extracellular pH using a pH-potentiometric sensing SECM dual-microelectrode
Extracellular pH can indicate the variation in organelle function and cell state. It is important to measure extracellular pH (pHe) with a controllable distance. In this work, a potentiometric SECM dual-microelectrode was developed to monitor the pHe of MCF-7 cells under electrical stimulation. The distance between the dual-microelectrode and the cells was determined first with a gold microelectrode by recording the approaching curve, and the pH was determined using an open-circuit potential (OCP) technique with a polyaniline-modified Pt microelectrode. The pH microelectrode showed a response slope of 53.0 ± 0.4 mV/pH and good reversibility from pH 4 to pH 8, fast response within 10 s, and a potential drift of 1.13% for 3 h, and thus was employed to monitor the pHe of stimulated cells. The value of pHe decreased with the decrease in the distance to cells, likely due to the release of H+. With an increase in the stimulation potential or time, the pHe value decreased, as the cell membrane became more permeable, which was verified by fluorescence staining of calcein-AM/PI (propidium iodide). Based on these results, this method can be widely applied for determining the species released by biosystems at a controllable position.
- 27 September 2017
- Published by Wiley in Journal of Applied Polymer Science
- Vol. 135 (5)
Gelation mechanism and rheological properties of polyacrylamide crosslinking with polyethyleneimine and its plugging performance in air‐foam displacement
Gels based on polyacrylamide crosslinking with polyethyleneimine have attracted attention because of their resulting high strength and good thermal stability. This study investigated the gelation mechanism of the polymeric gel and its plugging performance in air‐foam flooding. An optic microrheology analyzer was used to monitor the gelation process. The crosslinking reaction occurred in two steps, as determined from the elasticity factor curves, and the polymeric gels adopted a semisolid state from solution, as determined from the solid liquid balance curves. The elastic modulus values were higher than the viscous modulus values, indicating that mature gels were elastic‐based materials. The yield stress increased gradually with increasing polymer dosage, which was consistent with the breakthrough pressure and the trend of displacement pressure. The mature gels showed significant thixotropy. In the core displacement test, the preferred injection volume of the gel was 0.1 pore volume, and the stable pressure of the foam flooding was increased by about three times after the core was plugged. The blocking effect for cores with small original permeability was better than that with large permeability. The best blocking resulted from simultaneous treatment of both ends of the cores, followed by front‐end treatment and rear‐end treatment. © 2017 Wiley Periodicals, Inc. J. Appl. Polym. Sci. 2018, 135, 45778.
- 27 September 2017
- Published by Wiley in Journal of Applied Polymer Science
- Vol. 135 (5)
Gelation mechanism and rheological properties of polyacrylamide crosslinking with polyethyleneimine and its plugging performance in air‐foam displacement
Gels based on polyacrylamide crosslinking with polyethyleneimine have attracted attention because of their resulting high strength and good thermal stability. This study investigated the gelation mechanism of the polymeric gel and its plugging performance in air‐foam flooding. An optic microrheology analyzer was used to monitor the gelation process. The crosslinking reaction occurred in two steps, as determined from the elasticity factor curves, and the polymeric gels adopted a semisolid state from solution, as determined from the solid liquid balance curves. The elastic modulus values were higher than the viscous modulus values, indicating that mature gels were elastic‐based materials. The yield stress increased gradually with increasing polymer dosage, which was consistent with the breakthrough pressure and the trend of displacement pressure. The mature gels showed significant thixotropy. In the core displacement test, the preferred injection volume of the gel was 0.1 pore volume, and the stable pressure of the foam flooding was increased by about three times after the core was plugged. The blocking effect for cores with small original permeability was better than that with large permeability. The best blocking resulted from simultaneous treatment of both ends of the cores, followed by front‐end treatment and rear‐end treatment. © 2017 Wiley Periodicals, Inc. J. Appl. Polym. Sci. 2018, 135, 45778.
- 1 November 2016
- Published by Elsevier in Applied Surface Science
- Vol. 385, 616-621
Molecular dynamics investigation on the adsorption behaviors of H2O, CO2, CH4 and N2 gases on calcite (1 0) surface- 1 November 2016
- Published by Elsevier in Applied Surface Science
- Vol. 385, 616-621
Molecular dynamics investigation on the adsorption behaviors of H2O, CO2, CH4 and N2 gases on calcite (1 0) surface