MRI-based 3D cartilage modelling in the elbow joint
Authors:
- Tasuku MiyakeTMTasuku Miyake
- Satoshi MiyamuraSMSatoshi Miyamura
- Ryoya ShiodeRSRyoya Shiode
- Toru IwahashiTIToru Iwahashi
- Arisa KazuiAKArisa Kazui
- Natsuki YamamotoNYNatsuki Yamamoto
- Hiroki KondoHKHiroki Kondo
- Hiroyuki TanakaHTHiroyuki Tanaka
- Seiji OkadaSOSeiji Okada
- Tsuyoshi MuraseTMTsuyoshi Murase
- Kunihiro OkaKOKunihiro Oka
Open Access
- 8 July 2026
- journal article
- Published by British Editorial Society of Bone & Joint Surgery in Bone & Joint Research
- Vol. 15 (7) , 811-821
Abstract
Aims: To construct and validate a 3D MRI-based cartilage model of the elbow joint by comparing it with laser-scanned models and to assess how cartilage morphology influences intra-articular stress distribution through finite element analysis (FEA). Methods: Seven formalin-fixed cadaveric elbows were scanned using high-resolution MRI (voxel size: 0.375 × 0.375 × 0.400 mm), with sequences selected based on the contrast-to-noise ratio. Cartilage models of the distal humerus, radial head, and proximal ulna were reconstructed and validated against laser-scanned reference models. Validation metrics included cartilage thickness differences, surface-to-surface distances, and Dice similarity coefficients. Subsequently, FEA was performed using models with and without cartilage, under physiological loading, to evaluate the intra-articular stress distribution. Results: MRI-based and laser-scanned models showed similar cartilage thickness distributions, with differences within or close to the imaging resolution. The median cartilage thicknesses measured using the MRI-based and laser-scanned models were 1.15 mm (IQR 0.97 to 1.54) and 1.25 mm (IQR 1.14 to 1.29) in the distal humerus, 1.15 mm (IQR 0.97 to 1.18) and 1.03 mm (IQR 1.01 to 1.14) in the radial head, and 1.06 mm (IQR 0.93 to 1.21) and 1.05 mm (IQR 1.00 to 1.10) in the proximal ulna, respectively. The surface-to-surface root mean square distances were < 0.40 mm, and the Dice coefficients exceeded 0.96. FEA revealed physiologically plausible stress concentration patterns at anatomical contact areas only in models incorporating the cartilage. Conclusion: The 3D MRI-based cartilage models have high geometrical accuracy and biomechanical validity. These models offer a noninvasive tool for assessing cartilage morphology and joint mechanics, and may provide a foundation for future studies investigating the pathophysiology of elbow osteoarthritis. Cite this article: Bone Joint Res 2026;15(7):811–821.Keywords
This publication has 39 references indexed in Scilit:
- 3D isotropic spine echo MR imaging of elbow: How it helps surgical decisionsEuropean Journal of Radiology Open, 2022
- A novel three-dimensional MRI-CT image fusion technique for precise preoperative evaluation and treatment of capitellar osteochondritis dissecansEuropean Radiology, 2021
- Effect of elbow MRI with axial traction on articular cartilage visibility—a feasibility studySkeletal Radiology, 2020
- Impact of osteoarthritis on activities of daily living: does joint site matter?Aging Clinical and Experimental Research, 2019
- Anatomical variations of the trochlear notch angle: MRI analysis of 78 elbowsMUSCULOSKELETAL SURGERY, 2016
- Accuracy of specimen-specific nonlinear finite element analysis for evaluation of distal radius strength in cadaver materialJournal of Orthopaedic Science, 2014
- Effects of formalin fixation and collagen cross‐linking on T2 and magnetization transfer in bovine nasal cartilageMagnetic Resonance in Medicine, 2007
- Comparison of multislice CT arthrography and MR arthrography for the detection of articular cartilage lesions of the elbowEuropean Radiology, 2005
- In vivo morphometry and functional analysis of human articular cartilage with quantitative magnetic resonance imaging - from image to data, from data to theoryBrain Structure and Function, 2001
- Maximizing signal-to-noise and contrast-to-noise ratios in flash imagingMagnetic Resonance Imaging, 1987