NYNatsuki Yamamoto

Natsuki Yamamoto

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Natsuki Yamamoto has a total of 10 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    MRI-based 3D cartilage modelling in the elbow joint

    by Tasuku Miyake, Satoshi Miyamura, Ryoya Shiode, Toru Iwahashi, Arisa Kazui, Natsuki Yamamoto, Hiroki Kondo, Hiroyuki Tanaka, Seiji Okada, Tsuyoshi Murase, et al.

    Aims: To construct and validate a 3D MRI-based cartilage model of the elbow joint by comparing it with laser-scanned models and to assess how cartilage morphology influences intra-articular stress distribution through finite element analysis (FEA). Methods: Seven formalin-fixed cadaveric elbows were scanned using high-resolution MRI (voxel size: 0.375 × 0.375 × 0.400 mm), with sequences selected based on the contrast-to-noise ratio. Cartilage models of the distal humerus, radial head, and proximal ulna were reconstructed and validated against laser-scanned reference models. Validation metrics included cartilage thickness differences, surface-to-surface distances, and Dice similarity coefficients. Subsequently, FEA was performed using models with and without cartilage, under physiological loading, to evaluate the intra-articular stress distribution. Results: MRI-based and laser-scanned models showed similar cartilage thickness distributions, with differences within or close to the imaging resolution. The median cartilage thicknesses measured using the MRI-based and laser-scanned models were 1.15 mm (IQR 0.97 to 1.54) and 1.25 mm (IQR 1.14 to 1.29) in the distal humerus, 1.15 mm (IQR 0.97 to 1.18) and 1.03 mm (IQR 1.01 to 1.14) in the radial head, and 1.06 mm (IQR 0.93 to 1.21) and 1.05 mm (IQR 1.00 to 1.10) in the proximal ulna, respectively. The surface-to-surface root mean square distances were < 0.40 mm, and the Dice coefficients exceeded 0.96. FEA revealed physiologically plausible stress concentration patterns at anatomical contact areas only in models incorporating the cartilage. Conclusion: The 3D MRI-based cartilage models have high geometrical accuracy and biomechanical validity. These models offer a noninvasive tool for assessing cartilage morphology and joint mechanics, and may provide a foundation for future studies investigating the pathophysiology of elbow osteoarthritis. Cite this article: Bone Joint Res 2026;15(7):811–821.

  • Single-Stage Double-Level Osteotomy for Complex Cubitus Varus Involving the Humerus and Ulna

    by Satoshi Miyamura, Ryoya Shiode, Toru Iwahashi, Natsuki Yamamoto, Tasuku Miyake, Hiroki Kondo, Tsuyoshi Murase, Hiroyuki Tanaka, Seiji Okada, Kunihiro Oka

    Case: A 15-year-old male baseball pitcher presented with progressive cubitus varus deformity after multiple childhood elbow fractures treated conservatively. Three-dimensional evaluation demonstrated multiplanar deformities involving both the humerus and ulna. A single-stage double-level osteotomy was performed using patient-specific cutting guides and custom-made plates. Postoperatively, alignment was restored, bone union was achieved without complications, and the patient returned to competitive sport at 5 months, remaining asymptomatic at 36 months of follow-up. Conclusion: Complex cubitus varus involving multiple skeletal segments may not be correctable with single-level osteotomy. Double-level osteotomy allows anatomical realignment while preserving elbow joint orientation, reliably achieved using three-dimensional patient-specific techniques.