Factory-Calibrated Continuous Glucose Monitoring: How and Why It Works, and the Dangers of Reuse Beyond Approved Duration of Wear
- 30 March 2019
- journal article
- editorial
- Published by SAGE Publications in Diabetes Technology & Therapeutics
- Vol. 21 (4) , 222-229
Abstract
Continuous glucose monitors (CGM) display real-time glucose values enabling greater glycemic awareness with reduced management burden. Factory-calibrated CGM systems allow for glycemic assessment without the pain and inconvenience of fingerstick glucose testing. Advances in sensor chemistry and CGM algorithms have enabled factory-calibrated systems to have greater accuracy than previous generations of CGM technology. Despite these advances many patients and providers are hesitant about the idea of removing fingerstick testing from their diabetes care. In this commentary, we aim to review the clinical trials on factory-calibrated CGM systems, present the algorithms which facilitate factory-calibrated CGMs to improve accuracy, discuss clinical use of factory-calibrated CGMs, and finally present two cases demonstrating the dangers of utilizing exploits in commercial systems to prolong sensor life.Keywords
This publication has 32 references indexed in Scilit:
- The Performance and Usability of a Factory-Calibrated Flash Glucose Monitoring SystemDiabetes Technology & Therapeutics, 2015
- Online Calibration of Glucose Sensors From the Measured Current by a Time-Varying Calibration Function and Bayesian PriorsIEEE Transactions on Biomedical Engineering, 2015
- Feasibility of Factory Calibration for Subcutaneous Glucose Sensors in Subjects With DiabetesJournal of Diabetes Science and Technology, 2014
- Influence of fruit juice on fingertips and patient behavior on self-monitoring of blood glucoseDiabetes Research and Clinical Practice, 2012
- Glucose Monitoring After Fruit Peeling: Pseudohyperglycemia When Neglecting Hand Washing Before Fingertip Blood SamplingDiabetes Care, 2011
- Amperometric enzyme biosensors: Past, present and futureIRBM, 2008
- The Accuracy of the CGMS ™ in Children with Type 1 Diabetes: Results of the Diabetes Research in Children Network (DirecNet) Accuracy StudyDiabetes Technology & Therapeutics, 2003
- Calibration of a subcutaneous amperometric glucose sensorBiosensors and Bioelectronics, 2002
- The FDA Panel Advises Approval of the First Continuous Glucose SensorDiabetes Technology & Therapeutics, 1999
- Nonparametric input estimation in physiological systems: Problems, methods, and case studiesAutomatica, 1997