Abstract
Lumbar spinal fusion may cause adjacent segment degeneration (ASD) in the long term. Recently, inserting an interspinous process device (IPD) proximal to the fusion has been proposed to prevent ASD. The aim of this study was to investigate the biomechanics of lumbar fusion with proximal IPD implantation (LFPI) under both static loads and whole body vibration (WBV). A previously validated finite element (FE) model of the L1‐5 lumbar spine was modified to simulate L4‐5 fusion. Three different IPDs (Coflex‐F, Wallis and DIAM) were inserted at the L3‐4 segment of the fusion model to construct the LFPI models. The intact and surgical FE models were analyzed under static loads and WBV, respectively. Under static loading conditions, LFPI decreased range of motion (ROM) and intradiscal pressure (IDP) at the transition segment L3‐4 compared with the fusion case. At the segment (L2‐3) adjacent to the transition level, LFPI induced higher motion and IDP than rigid fusion. Under WBV, vibration amplitudes of the L3‐4 IDP and L4‐5 facet joint force (FJF) decreased by more than 54.3% after surgery. The LFPI model with the DIAM system offered the most comparable biomechanics to the intact model under static loads, and decreased the dynamic responses of the L4‐5 FJF under WBV. The LFPI model with the Wallis and Coflex‐F systems could stabilize the transition segment, and decrease dynamic responses of the L3‐4 IDP. The DIAM system may be more suitable in LFPI.Keywords
This publication has 31 references indexed in Scilit:
- Kinematic and Mechanical Comparisons of Lumbar Hybrid Fixation Using Dynesys and Cosmic SystemsSpine, 2014
- The effect of design parameters of interspinous implants on kinematics and load bearing: an in vitro studyEuropean Spine Journal, 2014
- Preventive Effect of Artificial Ligamentous Stabilization on the Upper Adjacent Segment Impairment Following Posterior Lumbar Interbody FusionSpine, 2009
- Does Wallis implant reduce adjacent segment degeneration above lumbosacral instrumented fusion?European Spine Journal, 2009
- Hybrid multidirectional test method to evaluate spinal adjacent-level effectsClinical Biomechanics, 2007
- Biomechanics of posterior dynamic stabilizing device (DIAM) after facetectomy and discectomyThe Spine Journal, 2006
- Critical Analysis of Trends in Fusion for Degenerative Disc Disease Over the Past 20 YearsSpine, 2004
- Correlation between sagittal plane changes and adjacent segment degeneration following lumbar spine fusionEuropean Spine Journal, 2001
- Self-Reported Back Pain in Fork-Lift Truck and Freight-Container Tractor Drivers Exposed to Whole-Body VibrationSpine, 1992