Weiqiang Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Weiqiang Liu has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
Zhenhua Liao
Biomechanics and Biotechnology Lab, Research Institute of Tsinghua University in Shenzhen, Shenzhen 518057, China
5 shared publicationsGuy R. Fogel
Spine Pain Begone Clinic San Antonio TX USA
3 shared publications- Hangkai Shen
Department of Mechanical Engineering Tsinghua University Beijing China
3 shared publications Jia Zhu
Biomechanics and Biotechnology Lab, Research Institute of Tsinghua University in Shenzhen, Shenzhen 518057, China
3 shared publicationsHangkai Shen
China United Engineering Corporation, China
2 shared publications- Jia Zhu
Tsinghua Shenzhen International Graduate School, Tsinghua University, Shenzhen 518055, China
2 shared publications
Latest Publications
- Open Access
- 3 April 2025
- Published by MDPI AG in Bioengineering
- Vol. 12 (4) , 384
A Biomechanical Evaluation of a Novel Interspinous Process Device: In Vitro Flexibility Assessment and Finite Element Analysis
The interspinous process device (IPD) has emerged as a viable alternative for managing lumbar degenerative pathologies. Nevertheless, limited research exists regarding mechanical failure modes including device failure and spinous process fracture. This study developed a novel IPD (IPD-NEW) and systematically evaluated its biomechanical characteristics through finite element (FE) analysis and in vitro cadaveric biomechanical testing. Six human L1–L5 lumbar specimens were subjected to mechanical testing under four experimental conditions: (1) Intact spine (control); (2) L3–L4 implanted with IPD-NEW; (3) L3–L4 implanted with Wallis device; (4) L3–L4 implanted with Coflex device. Segmental range of motion (ROM) was quantified across all test conditions. A validated L1–L5 finite element model was subsequently employed to assess biomechanical responses under both static and vertical vibration loading regimes. Comparative analysis revealed that IPD-NEW demonstrated comparable segmental ROM to the Wallis device while exhibiting lower rigidity than the Coflex implant. The novel design effectively preserved physiological spinal mobility while enhancing load distribution capacity. IPD-NEW demonstrated notable reductions in facet joint forces, device stress concentrations, and spinous process loading compared to conventional implants, particularly under vibrational loading conditions. These findings suggest that IPD-NEW may mitigate risks associated with facetogenic pain, device failure, and spinous process fracture through optimized load redistribution.
- 3 April 2025
- Published by MDPI AG in Bioengineering
- Vol. 12 (4) , 384
Open AccessA Biomechanical Evaluation of a Novel Interspinous Process Device: In Vitro Flexibility Assessment and Finite Element Analysis
The interspinous process device (IPD) has emerged as a viable alternative for managing lumbar degenerative pathologies. Nevertheless, limited research exists regarding mechanical failure modes including device failure and spinous process fracture. This study developed a novel IPD (IPD-NEW) and systematically evaluated its biomechanical characteristics through finite element (FE) analysis and in vitro cadaveric biomechanical testing. Six human L1–L5 lumbar specimens were subjected to mechanical testing under four experimental conditions: (1) Intact spine (control); (2) L3–L4 implanted with IPD-NEW; (3) L3–L4 implanted with Wallis device; (4) L3–L4 implanted with Coflex device. Segmental range of motion (ROM) was quantified across all test conditions. A validated L1–L5 finite element model was subsequently employed to assess biomechanical responses under both static and vertical vibration loading regimes. Comparative analysis revealed that IPD-NEW demonstrated comparable segmental ROM to the Wallis device while exhibiting lower rigidity than the Coflex implant. The novel design effectively preserved physiological spinal mobility while enhancing load distribution capacity. IPD-NEW demonstrated notable reductions in facet joint forces, device stress concentrations, and spinous process loading compared to conventional implants, particularly under vibrational loading conditions. These findings suggest that IPD-NEW may mitigate risks associated with facetogenic pain, device failure, and spinous process fracture through optimized load redistribution.
- 12 August 2022
- Published by Elsevier in Clinical Biomechanics
- Vol. 98, 105738
Study on the process of intervertebral disc disease by the theory of continuum damage mechanics
- 12 August 2022
- Published by Elsevier in Clinical Biomechanics
- Vol. 98, 105738
Study on the process of intervertebral disc disease by the theory of continuum damage mechanics
- Open Access
- 10 August 2022
- Published by Wiley in Orthopaedic Surgery
- Vol. 14 (9) , 2339-2349
Biomechanical Evaluation of Transforaminal Lumbar Interbody Fusion with Coflex‐F and Pedicle Screw Fixation: Finite Element Analysis of Static and Vibration Conditions
Objective: To investigate the biomechanics of transforaminal lumbar interbody fusion (TLIF) with interspinous process device (IPD) or pedicle screw fixation under both static and vibration conditions by the finite element (FE) method.Method: A validated FE model of the L1‐5 lumbar spine was used in this study. This FE model derived from computed tomography images of a healthy female adult volunteer of appropriate age. Then the model was modified to simulate L3‐4 TLIF. Four conditions were compared: (i) intact; (ii) TLIF combined with bilateral pedicle screw fixation (BPSF); (iii) TLIF combined with U‐shaped IPD Coflex‐F (CF); and (iv) TLIF combined with unilateral pedicle screw fixation (UPSF). The intact and surgical FE models were analyzed under static and vibration loading conditions respectively. For static loading conditions, four motion modes (flexion, extension, lateral bending, and axial rotation) were simulated. For vibration loading conditions, the dynamic responses of lumbar spine under sinusoidal vertical load were simulated.Result: Under static loading conditions, compared with intact case, BPSF decreased range of motion (ROM) by 92%, 95%, 89% and 92% in flexion, extension, lateral bending and axial rotation, respectively. While CF decreased ROM by 87%, 90%, 69% and 80%, and UPSF decreased ROM by 84%, 89%, 66% and 82%, respectively. Compared with CF, UPSF increased the endplate stress by 5%–8% in flexion, 7%–10% in extension, 2%–4% in lateral bending, and decreased the endplate stress by 16%–19% in axial rotation. Compared with CF, UPSF increased the cage stress by 9% in flexion, 10% in extension, and decreased the cage stress by 3% in lateral bending, and 13% in axial rotation. BPSF decreased the stress responses of endplates and cage compared with CF and UPSF. Compared BPSF, CF decreased the facet joint force (FJF) by 6%–13%, and UPSF decreased the FJF by 4%–12%. During vibration loading conditions, compared with BPSF, CF reduced maximum values of the FJF by 16%–32%, and vibration amplitudes by 22%–35%, while UPSF reduced maximum values by 20%–40%, and vibration amplitudes by 31%–45%.Conclusion: Compared with other surgical models, BPSF increased the stability of lumbar spine, and also showed advantages in cage stress and endplate stress. CF showed advantages in IDP and FJF especially during vertical vibration, which may lead to lower risk of adjacent segment degeneration. CF may be an effective alternative to pedicle screw fixation in TLIF procedures.
- 10 August 2022
- Published by Wiley in Orthopaedic Surgery
- Vol. 14 (9) , 2339-2349
Open AccessBiomechanical Evaluation of Transforaminal Lumbar Interbody Fusion with Coflex‐F and Pedicle Screw Fixation: Finite Element Analysis of Static and Vibration Conditions
Objective: To investigate the biomechanics of transforaminal lumbar interbody fusion (TLIF) with interspinous process device (IPD) or pedicle screw fixation under both static and vibration conditions by the finite element (FE) method.Method: A validated FE model of the L1‐5 lumbar spine was used in this study. This FE model derived from computed tomography images of a healthy female adult volunteer of appropriate age. Then the model was modified to simulate L3‐4 TLIF. Four conditions were compared: (i) intact; (ii) TLIF combined with bilateral pedicle screw fixation (BPSF); (iii) TLIF combined with U‐shaped IPD Coflex‐F (CF); and (iv) TLIF combined with unilateral pedicle screw fixation (UPSF). The intact and surgical FE models were analyzed under static and vibration loading conditions respectively. For static loading conditions, four motion modes (flexion, extension, lateral bending, and axial rotation) were simulated. For vibration loading conditions, the dynamic responses of lumbar spine under sinusoidal vertical load were simulated.Result: Under static loading conditions, compared with intact case, BPSF decreased range of motion (ROM) by 92%, 95%, 89% and 92% in flexion, extension, lateral bending and axial rotation, respectively. While CF decreased ROM by 87%, 90%, 69% and 80%, and UPSF decreased ROM by 84%, 89%, 66% and 82%, respectively. Compared with CF, UPSF increased the endplate stress by 5%–8% in flexion, 7%–10% in extension, 2%–4% in lateral bending, and decreased the endplate stress by 16%–19% in axial rotation. Compared with CF, UPSF increased the cage stress by 9% in flexion, 10% in extension, and decreased the cage stress by 3% in lateral bending, and 13% in axial rotation. BPSF decreased the stress responses of endplates and cage compared with CF and UPSF. Compared BPSF, CF decreased the facet joint force (FJF) by 6%–13%, and UPSF decreased the FJF by 4%–12%. During vibration loading conditions, compared with BPSF, CF reduced maximum values of the FJF by 16%–32%, and vibration amplitudes by 22%–35%, while UPSF reduced maximum values by 20%–40%, and vibration amplitudes by 31%–45%.Conclusion: Compared with other surgical models, BPSF increased the stability of lumbar spine, and also showed advantages in cage stress and endplate stress. CF showed advantages in IDP and FJF especially during vertical vibration, which may lead to lower risk of adjacent segment degeneration. CF may be an effective alternative to pedicle screw fixation in TLIF procedures.
- 17 May 2021
- Published by Wiley in International Journal for Numerical Methods in Biomedical Engineering
- Vol. 37 (8) , e3498
Biomechanical analysis of lumbar fusion with proximal interspinous process device implantation
Lumbar spinal fusion may cause adjacent segment degeneration (ASD) in the long term. Recently, inserting an interspinous process device (IPD) proximal to the fusion has been proposed to prevent ASD. The aim of this study was to investigate the biomechanics of lumbar fusion with proximal IPD implantation (LFPI) under both static loads and whole body vibration (WBV). A previously validated finite element (FE) model of the L1‐5 lumbar spine was modified to simulate L4‐5 fusion. Three different IPDs (Coflex‐F, Wallis and DIAM) were inserted at the L3‐4 segment of the fusion model to construct the LFPI models. The intact and surgical FE models were analyzed under static loads and WBV, respectively. Under static loading conditions, LFPI decreased range of motion (ROM) and intradiscal pressure (IDP) at the transition segment L3‐4 compared with the fusion case. At the segment (L2‐3) adjacent to the transition level, LFPI induced higher motion and IDP than rigid fusion. Under WBV, vibration amplitudes of the L3‐4 IDP and L4‐5 facet joint force (FJF) decreased by more than 54.3% after surgery. The LFPI model with the DIAM system offered the most comparable biomechanics to the intact model under static loads, and decreased the dynamic responses of the L4‐5 FJF under WBV. The LFPI model with the Wallis and Coflex‐F systems could stabilize the transition segment, and decrease dynamic responses of the L3‐4 IDP. The DIAM system may be more suitable in LFPI.
- 17 May 2021
- Published by Wiley in International Journal for Numerical Methods in Biomedical Engineering
- Vol. 37 (8) , e3498
Biomechanical analysis of lumbar fusion with proximal interspinous process device implantation
Lumbar spinal fusion may cause adjacent segment degeneration (ASD) in the long term. Recently, inserting an interspinous process device (IPD) proximal to the fusion has been proposed to prevent ASD. The aim of this study was to investigate the biomechanics of lumbar fusion with proximal IPD implantation (LFPI) under both static loads and whole body vibration (WBV). A previously validated finite element (FE) model of the L1‐5 lumbar spine was modified to simulate L4‐5 fusion. Three different IPDs (Coflex‐F, Wallis and DIAM) were inserted at the L3‐4 segment of the fusion model to construct the LFPI models. The intact and surgical FE models were analyzed under static loads and WBV, respectively. Under static loading conditions, LFPI decreased range of motion (ROM) and intradiscal pressure (IDP) at the transition segment L3‐4 compared with the fusion case. At the segment (L2‐3) adjacent to the transition level, LFPI induced higher motion and IDP than rigid fusion. Under WBV, vibration amplitudes of the L3‐4 IDP and L4‐5 facet joint force (FJF) decreased by more than 54.3% after surgery. The LFPI model with the DIAM system offered the most comparable biomechanics to the intact model under static loads, and decreased the dynamic responses of the L4‐5 FJF under WBV. The LFPI model with the Wallis and Coflex‐F systems could stabilize the transition segment, and decrease dynamic responses of the L3‐4 IDP. The DIAM system may be more suitable in LFPI.
- 1 April 2021
- Published by Elsevier in Clinical Biomechanics
- Vol. 84, 105339
Biomechanical evaluation of anterior lumbar interbody fusion with various fixation options: Finite element analysis of static and vibration conditions
- 1 April 2021
- Published by Elsevier in Clinical Biomechanics
- Vol. 84, 105339
Biomechanical evaluation of anterior lumbar interbody fusion with various fixation options: Finite element analysis of static and vibration conditions
- 1 July 2019
- Published by Elsevier in World Neurosurgery
- Vol. 127, e1112-e1119
Biomechanical Analysis of Different Lumbar Interspinous Process Devices: A Finite Element Study
- 1 July 2019
- Published by Elsevier in World Neurosurgery
- Vol. 127, e1112-e1119
Biomechanical Analysis of Different Lumbar Interspinous Process Devices: A Finite Element Study