Automatic phase determination for retrospectively gated cardiac CT
Authors:
- 22 November 2004
- journal article
- clinical trial
- Published by Wiley in Medical Physics
- Vol. 31 (12) , 3345-3362
Abstract
The recent improvements in CT detector and gantry technology in combination with new heart rate adaptive cone beam reconstruction algorithms enable the visualization of the heart in three dimensions at high spatial resolution. However, the finite temporal resolution still impedes the artifact‐free reconstruction of the heart at any arbitrary phase of the cardiac cycle. Cardiac phases must be found during which the heart is quasistationary to obtain outmost image quality. It is challenging to find these phases due to intercycle and patient‐to‐patient variability. Electrocardiogram (ECG) information does not always represent the heart motion with an adequate accuracy. In this publication, a simple and efficient image‐based technique is introduced which is able to deliver stable cardiac phases in an automatic and patient‐specific way. From low‐resolution four‐dimensional data sets, the most stable phases are derived by calculating the object similarity between subsequent phases in the cardiac cycle. Patient‐specific information about the object motion can be determined and resolved spatially. This information is used to perform optimized high‐resolution reconstructions at phases of little motion. Results based on a simulation study and three real patient data sets are presented. The projection data were generated using a 16‐slice cone beam CT system in low‐pitch helical mode with parallel ECG recording.Keywords
This publication has 29 references indexed in Scilit:
- Artifact Analysis and Reconstruction Improvement in Helical Cardiac Cone Beam CTIEEE Transactions on Medical Imaging, 2004
- Evaluation of Reconstruction Windows for Multislice Computed Tomography in Quantification of Coronary CalciumInvestigative Radiology, 2003
- Non-invasive coronary angiography with high resolution multidetector-row computed tomography. Results in 102 patientsEuropean Heart Journal, 2002
- Variation of the Coronary Calcium Score Depending on Image Reconstruction Interval and Scoring AlgorithmInvestigative Radiology, 2002
- Kymogram detection and kymogram‐correlated image reconstruction from subsecond spiral computed tomography scans of the heartMedical Physics, 2002
- ECG‐correlated image reconstruction from subsecond multi‐slice spiral CT scans of the heartMedical Physics, 2000
- High temporal resolution for multislice helical computed tomographyMedical Physics, 2000
- Multislice helical CT: image temporal resolutionIEEE Transactions on Medical Imaging, 2000
- ECG-correlated imaging of the heart with subsecond multislice spiral CTIEEE Transactions on Medical Imaging, 2000
- Systolic Time Intervals in Heart Failure in ManCirculation, 1968