In vitro optical quality measurements of three intraocular lens models having identical platform
Open Access
- 29 June 2017
- journal article
- research article
- Published by Springer Nature in BMC Ophthalmology
- Vol. 17 (1) , 1-9
Abstract
With recent advances in technology and introduction of new intraocular lens (IOL) models, surgeons today have the opportunity to choose from various optical designs, which can influence the postoperative quality of vision. In our laboratory study, we compared the optical quality of three different IOLs that use the identical platform and are produced by the same manufacturer. The study included two diffractive multifocal IOLs, a bifocal and a trifocal one, as well as a monofocal IOL. Three IOL models: monofocal CT ASPHINA 409 M, diffractive bifocal AT LISA 809 M, and diffractive trifocal AT LISA Tri 839MP (Carl Zeiss Meditec AG, Germany) were assessed for optical quality by measuring modulation transfer function (MTF) and Strehl Ratio (SR) values at pupil sizes of 3.0 and 4.5 mm on the OptiSpheric® IOL PRO (Trioptics GmbH, Germany). The United States Air Force (USAF) Target images were also recorded to comfirm the optical performance qualitatively. For far focus at 50 lp/mm and 3.0 mm pupil size, MTF value of the monofocal lens (MTF = 0.798) was 1.8-fold and 2.1-fold better than the bifocal (MTF = 0.446) and the trifocal (MTF = 0.382) IOLs, respectively. For near focus, bifocal IOL (MTF = 0.265) was 1.4-fold better than trifocal IOL (MTF = 0.187), while for intermediate focus, the trifocal IOL (MTF = 0.148) was 1.7-fold better than the bifocal IOL (MTF = 0.086). For the same pupil size, total sum of light loss amounted to 5.2% for the monofocal, 16.0% for the bifocal and 6.0% for the trifocal IOL. For a larger pupil, the amount of light loss increased significantly for the multifocal IOLs. The monofocal IOL performed the best for far, the bifocal IOL for near and the trifocal IOL for intermediate focus. While the monofocal IOL created the least amount of light loss for both pupil sizes, the trifocal IOL created less than half the amount of light loss than the bifocal IOL for small pupil. For large pupil, however, less light scatter was observed for the bifocal than the trifocal IOL.Keywords
Funding Information
- Klaus Tschira Stiftung
This publication has 28 references indexed in Scilit:
- In vitro optical quality differences between multifocal apodized diffractive intraocular lensesJournal of Cataract & Refractive Surgery, 2013
- Evidence-based guidelines for cataract surgery: Guidelines based on data in the European Registry of Quality Outcomes for Cataract and Refractive Surgery databaseJournal of Cataract & Refractive Surgery, 2012
- Global estimates of visual impairment: 2010British Journal of Ophthalmology, 2011
- The effect of chromatic dispersion on pseudophakic optical performanceBritish Journal of Ophthalmology, 2007
- Imaging quality of intraocular lensesJournal of Cataract & Refractive Surgery, 2005
- Analysis of the Optical Quality of Intraocular LensesInvestigative Ophthalmology & Visual Science, 2004
- Effect of Chromatic Aberration on Contrast Sensitivity in Pseudophakic EyesArchives of Ophthalmology (1950), 2001
- A new approach to the study of ocular chromatic aberrationsVision Research, 1999
- [Chromatic aberration in pseudophakic eyes].1999
- Comparison of pseudoaccommodation and visual quality between a diffractive and refractive multifocal intraocular lensJournal of Cataract & Refractive Surgery, 1998