Chul Young Choi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Chul Young Choi has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Ramin Khoramnia
The David J. Apple Center for Vision Research, Department of Ophthalmology, University of Heidelberg, Heidelberg, Germany
9 shared publications - Gerd Uwe Auffarth
International Vision Correction Research Centre (IVCRC), Department of Ophthalmology, University of Heidelberg, INF 400, 69120 Heidelberg, Germany
8 shared publications - Tamer Tandogan
Department of Ophthalmology, University of Heidelberg, Heidelberg, Germany
4 shared publications - Hyeck-Soo Son
The David J. Apple Center for Vision Research, Department of Ophthalmology, University of Heidelberg, Heidelberg, Germany
3 shared publications - Tamer Tandogan
Department of Ophthalmology, Pallas Kliniken, Olten, Switzerland
3 shared publications - Grzegorz Łabuz
The David J. Apple Center for Vision Research, Department of Ophthalmology, University of Heidelberg, Heidelberg, Germany
2 shared publications
Latest Publications
- Open Access
- 19 May 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (10) , 1804
Imaging Function and Relative Light Transmission of Explanted Opacified Hydrophilic Acrylic Intraocular Lenses
We evaluated the influence of intraocular lens (IOL) opacification on the optical performance of explanted hydrophilic acrylic IOLs. We performed a laboratory analysis of 32 Lentis LS-502-1 (Oculentis GmbH, Berlin, Germany) IOLs, explanted due to opacification, in comparison with six clear unused samples of the same IOL model. Using an optical bench setup, we obtained modulation transfer function (MTF), Strehl ratio, two-dimensional MTF, and United States Air Force (USAF) chart images. In addition, we assessed light transmission through the IOLs. The MTF values of opacified IOLs at 3-mm aperture were similar to those of clear lenses, with the median (interquartile range) values of 0.74 (0.01) vs. 0.76 (0.03) at the spatial frequency of 50 line pairs per millimeter in clear and opacified IOLs, respectively. The Strehl ratio of opacified lenses was not lower than that of clear lenses. The USAF-chart analysis showed a considerable reduction in brightness in opacified IOLs. The median (interquartile range) relative light transmission of opacified IOLs in comparison to clear lenses was 55.6% (20.8%) at the aperture size of 3 mm. In conclusion, the explanted opacified IOLs had comparable MTF values to those of clear lenses but significantly reduced light transmission.
- 19 May 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (10) , 1804
Open AccessImaging Function and Relative Light Transmission of Explanted Opacified Hydrophilic Acrylic Intraocular Lenses
We evaluated the influence of intraocular lens (IOL) opacification on the optical performance of explanted hydrophilic acrylic IOLs. We performed a laboratory analysis of 32 Lentis LS-502-1 (Oculentis GmbH, Berlin, Germany) IOLs, explanted due to opacification, in comparison with six clear unused samples of the same IOL model. Using an optical bench setup, we obtained modulation transfer function (MTF), Strehl ratio, two-dimensional MTF, and United States Air Force (USAF) chart images. In addition, we assessed light transmission through the IOLs. The MTF values of opacified IOLs at 3-mm aperture were similar to those of clear lenses, with the median (interquartile range) values of 0.74 (0.01) vs. 0.76 (0.03) at the spatial frequency of 50 line pairs per millimeter in clear and opacified IOLs, respectively. The Strehl ratio of opacified lenses was not lower than that of clear lenses. The USAF-chart analysis showed a considerable reduction in brightness in opacified IOLs. The median (interquartile range) relative light transmission of opacified IOLs in comparison to clear lenses was 55.6% (20.8%) at the aperture size of 3 mm. In conclusion, the explanted opacified IOLs had comparable MTF values to those of clear lenses but significantly reduced light transmission.
- Open Access
- 22 August 2021
- Published by MDPI AG in Diagnostics
- Vol. 11 (8) , 1512
Visualization of Forward Light Scatter in Opacified Intraocular Lenses and Straylight Assessment
Background: Qualitative visualization of forward light scatter and quantitative straylight measurement of intraocular lenses (IOLs). Methods: We analyzed two calcified IOL-explants, the Euromaxx ALI313Y (Argonoptics GmbH) and the LS-312 MF30 (Oculentis BV), one IOL with artificially induced glistenings (PC-60AD, Hoya), and one control (CT Asphina 409MP, Carl Zeiss Meditec AG) free of any opacification. Analysis included light microscopy, qualitative light scatter visualization using ray propagation imaging technique, and quantitative straylight measurement using C-Quant (Oculus). Results: More light scattering effect—visible as increased light intensity outside the IOL’s main focus—was evident in all opacified IOLs than the control. The highest straylight levels were observed in the Euromaxx (289.71 deg2/sr), which showed extensive granular deposits throughout its optic, followed by the MF30 (78.58 deg2/sr), which only showed opacification in its center. The glistenings-IOL demonstrated numerous microvacuoles within the optic and had straylight levels of 22.6 deg2/sr, while the control showed the lowest straylight levels (1.7 deg2/sr). Conclusions: Ray propagation imaging technique allowed qualitative assessment of off-axis veils of light that result from increased forward light scattering. Straylight was increased in all opacified lenses compared to the clear control lens. The IOL opacifications are significant sources of glare.
- 22 August 2021
- Published by MDPI AG in Diagnostics
- Vol. 11 (8) , 1512
Open AccessVisualization of Forward Light Scatter in Opacified Intraocular Lenses and Straylight Assessment
Background: Qualitative visualization of forward light scatter and quantitative straylight measurement of intraocular lenses (IOLs). Methods: We analyzed two calcified IOL-explants, the Euromaxx ALI313Y (Argonoptics GmbH) and the LS-312 MF30 (Oculentis BV), one IOL with artificially induced glistenings (PC-60AD, Hoya), and one control (CT Asphina 409MP, Carl Zeiss Meditec AG) free of any opacification. Analysis included light microscopy, qualitative light scatter visualization using ray propagation imaging technique, and quantitative straylight measurement using C-Quant (Oculus). Results: More light scattering effect—visible as increased light intensity outside the IOL’s main focus—was evident in all opacified IOLs than the control. The highest straylight levels were observed in the Euromaxx (289.71 deg2/sr), which showed extensive granular deposits throughout its optic, followed by the MF30 (78.58 deg2/sr), which only showed opacification in its center. The glistenings-IOL demonstrated numerous microvacuoles within the optic and had straylight levels of 22.6 deg2/sr, while the control showed the lowest straylight levels (1.7 deg2/sr). Conclusions: Ray propagation imaging technique allowed qualitative assessment of off-axis veils of light that result from increased forward light scattering. Straylight was increased in all opacified lenses compared to the clear control lens. The IOL opacifications are significant sources of glare.
- Open Access
- 19 May 2021
- Published by Springer Nature in International Ophthalmology
- Vol. 41 (9) , 3073-3080
Comparative analysis of in vitro accelerated glistening formation in foldable hydrophobic intraocular lenses
Purpose: To analyse and compare the propensity to form glistenings in 4 different types of hydrophobic acrylic intraocular lenses (IOLs): Alcon AcrySof ® MA60AC, HOYA iSert® PC-60AD, Bausch&Lomb enVista, and Kowa Avansee™ PU6A. Methods: We used an accelerated laboratory method to create glistenings. IOLs were first immersed in saline at 45 °C for 24 h and then at 37 °C for 2.5 h. Microvacuole (MV) density and size were documented and calculated using an image analysis program. Results: Median density of glistenings [MV/mm2] for Alcon AcrySof ® MA60AC was 623 (range 507–804), for HOYA iSert® PC-60AD 1358 (range 684–2699), for Bausch&Lomb enVista 2 (range 1–2), and for Kowa Avansee™ PU6A 1 (range 1–4). The prevailing MV size was: 0–5 µm for Hoya IOLs, 5–10 µm for Alcon IOLs, 20–50 µm for Bausch&Lomb IOLs, and 5–50 µm for Kowa IOLs. Conclusions: Glistenings could be induced in all studied IOLs using the accelerated laboratory method. The Alcon AcrySof ® MA60AC and HOYA iSert® PC-60AD IOLs showed MV of high density, while the glistenings in the Hoya IOLs were smaller in size compared to the Alcon IOLs. The MV density was minimal in the Bausch&Lomb enVista and Kowa Avansee™ PU6A IOLs. The propensity of the Alcon AcrySof ® MA60AC IOLs to form glistenings in vitro correlated with the findings of clinical results that are already published.
- 19 May 2021
- Published by Springer Nature in International Ophthalmology
- Vol. 41 (9) , 3073-3080
Open AccessComparative analysis of in vitro accelerated glistening formation in foldable hydrophobic intraocular lenses
Purpose: To analyse and compare the propensity to form glistenings in 4 different types of hydrophobic acrylic intraocular lenses (IOLs): Alcon AcrySof ® MA60AC, HOYA iSert® PC-60AD, Bausch&Lomb enVista, and Kowa Avansee™ PU6A. Methods: We used an accelerated laboratory method to create glistenings. IOLs were first immersed in saline at 45 °C for 24 h and then at 37 °C for 2.5 h. Microvacuole (MV) density and size were documented and calculated using an image analysis program. Results: Median density of glistenings [MV/mm2] for Alcon AcrySof ® MA60AC was 623 (range 507–804), for HOYA iSert® PC-60AD 1358 (range 684–2699), for Bausch&Lomb enVista 2 (range 1–2), and for Kowa Avansee™ PU6A 1 (range 1–4). The prevailing MV size was: 0–5 µm for Hoya IOLs, 5–10 µm for Alcon IOLs, 20–50 µm for Bausch&Lomb IOLs, and 5–50 µm for Kowa IOLs. Conclusions: Glistenings could be induced in all studied IOLs using the accelerated laboratory method. The Alcon AcrySof ® MA60AC and HOYA iSert® PC-60AD IOLs showed MV of high density, while the glistenings in the Hoya IOLs were smaller in size compared to the Alcon IOLs. The MV density was minimal in the Bausch&Lomb enVista and Kowa Avansee™ PU6A IOLs. The propensity of the Alcon AcrySof ® MA60AC IOLs to form glistenings in vitro correlated with the findings of clinical results that are already published.
- 12 October 2017
- Published by Georg Thieme Verlag KG in Klinische Monatsblätter für Augenheilkunde
- Vol. 234 (12) , 1533-1539
Auswirkungen der Nahaddition auf die optische Qualität von diffraktiven multifokalen Intraokularlinsen – eine Laborstudie an der optischen Bank
Ziel Analyse und Vergleich der optischen Qualität diffraktiver multifokaler Intraokularlinsen (IOL) mit unterschiedlichen Nahadditionen mithilfe einer optischen Bank im Rahmen einer Laborstudie. Methode Die AcrySof® IQ ReSTOR® + 2.5 D SV25T0 (Alcon, USA), die AcrySof® IQ ReSTOR® + 3.0 D SN6AD1 (Alcon, USA) sowie die TECNIS® ZMA00 und ZMB00 (Abbott Medical Optics, USA) mit einer Brechkraft von 21 dpt für die Ferne wurden an der optischen Bank OptiSpheric® IOL PRO (TRIOPTICS GmbH, Wedel) untersucht. Das optische Design dieser Linsen ist ähnlich, die Modelle unterscheiden sich allerdings hinsichtlich ihrer Nahaddition: Die AcrySof IQ ReSTOR + 2.5 D hat eine Nahaddition von + 2,5 dpt, die AcrySof IQ ReSTOR + 3.0 D eine Nahaddition von + 3,0 dpt und beide TECNIS-Linsen eine Nahaddition von + 4,0 dpt. Untersucht wurden die Fläche unterhalb der Kurve der Modulationstransferfunktion (Modulation Transfer Function Area, MTFA) und die Strehl Ratio. Weiterhin wurden die Abbildungseigenschaften der IOL mithilfe von USAF-Target-Bildern (USAF: United States Air Force) qualitativ miteinander verglichen. Ergebnis Die MTFA-Werte für den Fernfokus waren im Median 47,85/42,06/33,57 (2,5 dpt/3,0 dpt/4,0 dpt). Für den Intermediärfokus erreichten die MTFA-Werte 11,05/9,54/8,60. Die MTFA-Werte für den Nahfokus waren 20,11/29,50/33,39. Die Strehl Ratio des Fernfokus betrug 0,48/0,42/0,29. Für den Intermediärfokus war die Strehl Ratio 0,11/0,10/0,09. Die Strehl Ratio des Nahfokus betrug 0,20/0,30/0,34. Die USAF-Target-Bilder korrelierten mit diesen Messwerten. Schlussfolgerung Für den Nahfokus erzielen die ZMA00 und ZMB00 die besten Ergebnisse, während die IQ ReSTOR + 2.5 D am schlechtesten abschneidet. Im Intermediärbereich erreichen alle IOL ähnliche Ergebnisse. Für den Fernfokus erzielt die IQ ReSTOR + 2.5 D die besten Ergebnisse. Da heutzutage diverse Nahadditionen bei diffraktiven multifokalen IOL zur Verfügung stehen, kann die Wahl der richtigen Linse individuell auf die Bedürfnisse jedes Patienten abgestimmt werden. Purpose To analyse the optical quality of diffractive multifocal intraocular lenses (IOLs) with different near additions in a laboratory study. Methods We analysed the AcrySof® IQ ReSTOR® + 2.5 D SV25T0 (Alcon Laboratories inc., Fort Worth, USA), the AcrySof® IQ ReSTOR® + 3.0 D SN6AD1 (Alcon, USA) and the TECNIS® ZMA00 and ZMB00 (Abbott Medical Optics, USA) with a power of 21D for the distance, using the OptiSpheric® IOL PRO optical bench (TRIOPTICS, Wedel, Germany). The lenses have a similar optical design but different near additions: The ReSTOR + 2.5 D has a near addition of + 2.5 D, the ReSTOR + 3.0 D has a near addition of + 3.0 D and both TECNIS IOLs have a near addition of + 4.0 D. We evaluated the modulation transfer function area (MTFA) and the Strehl ratio. Additionally the optical qualities of the IOL were compared using USAF (United States Air Force)-Target pictures. Results The MTFA at the far focus (ReSTOR + 2.5 D/ReSTOR + 3.0 D/TECNIS) was 47.85/42.06/33.57. The MTFA was 11.05/9.54/8.60 for intermediate distances. MTFA at the near focus was 20.11/29.50/33.39. The Strehl ratio was 0.48/0.42/0.29 at the far focus, 0.11/0.10/0.09 at the intermediate focus and 0.20/0.30/0.34 at the near focus. The USAF Target pictures correlated with these measurements. Conclusion At the near focus, the TECNIS ZMA00 and ZMB00 performed the best, while the ReSTOR + 2.5 D performed the worst. At the intermediate distance, all IOLs achieved similar results. At the far focus, the ReSTOR + 2.5 D performed the best. Surgeons can choose the right IOL for the patientsʼ individual needs, because a broad range of near additions in diffractive multifocal IOLs is available these days.
- 12 October 2017
- Published by Georg Thieme Verlag KG in Klinische Monatsblätter für Augenheilkunde
- Vol. 234 (12) , 1533-1539
Auswirkungen der Nahaddition auf die optische Qualität von diffraktiven multifokalen Intraokularlinsen – eine Laborstudie an der optischen Bank
Ziel Analyse und Vergleich der optischen Qualität diffraktiver multifokaler Intraokularlinsen (IOL) mit unterschiedlichen Nahadditionen mithilfe einer optischen Bank im Rahmen einer Laborstudie. Methode Die AcrySof® IQ ReSTOR® + 2.5 D SV25T0 (Alcon, USA), die AcrySof® IQ ReSTOR® + 3.0 D SN6AD1 (Alcon, USA) sowie die TECNIS® ZMA00 und ZMB00 (Abbott Medical Optics, USA) mit einer Brechkraft von 21 dpt für die Ferne wurden an der optischen Bank OptiSpheric® IOL PRO (TRIOPTICS GmbH, Wedel) untersucht. Das optische Design dieser Linsen ist ähnlich, die Modelle unterscheiden sich allerdings hinsichtlich ihrer Nahaddition: Die AcrySof IQ ReSTOR + 2.5 D hat eine Nahaddition von + 2,5 dpt, die AcrySof IQ ReSTOR + 3.0 D eine Nahaddition von + 3,0 dpt und beide TECNIS-Linsen eine Nahaddition von + 4,0 dpt. Untersucht wurden die Fläche unterhalb der Kurve der Modulationstransferfunktion (Modulation Transfer Function Area, MTFA) und die Strehl Ratio. Weiterhin wurden die Abbildungseigenschaften der IOL mithilfe von USAF-Target-Bildern (USAF: United States Air Force) qualitativ miteinander verglichen. Ergebnis Die MTFA-Werte für den Fernfokus waren im Median 47,85/42,06/33,57 (2,5 dpt/3,0 dpt/4,0 dpt). Für den Intermediärfokus erreichten die MTFA-Werte 11,05/9,54/8,60. Die MTFA-Werte für den Nahfokus waren 20,11/29,50/33,39. Die Strehl Ratio des Fernfokus betrug 0,48/0,42/0,29. Für den Intermediärfokus war die Strehl Ratio 0,11/0,10/0,09. Die Strehl Ratio des Nahfokus betrug 0,20/0,30/0,34. Die USAF-Target-Bilder korrelierten mit diesen Messwerten. Schlussfolgerung Für den Nahfokus erzielen die ZMA00 und ZMB00 die besten Ergebnisse, während die IQ ReSTOR + 2.5 D am schlechtesten abschneidet. Im Intermediärbereich erreichen alle IOL ähnliche Ergebnisse. Für den Fernfokus erzielt die IQ ReSTOR + 2.5 D die besten Ergebnisse. Da heutzutage diverse Nahadditionen bei diffraktiven multifokalen IOL zur Verfügung stehen, kann die Wahl der richtigen Linse individuell auf die Bedürfnisse jedes Patienten abgestimmt werden. Purpose To analyse the optical quality of diffractive multifocal intraocular lenses (IOLs) with different near additions in a laboratory study. Methods We analysed the AcrySof® IQ ReSTOR® + 2.5 D SV25T0 (Alcon Laboratories inc., Fort Worth, USA), the AcrySof® IQ ReSTOR® + 3.0 D SN6AD1 (Alcon, USA) and the TECNIS® ZMA00 and ZMB00 (Abbott Medical Optics, USA) with a power of 21D for the distance, using the OptiSpheric® IOL PRO optical bench (TRIOPTICS, Wedel, Germany). The lenses have a similar optical design but different near additions: The ReSTOR + 2.5 D has a near addition of + 2.5 D, the ReSTOR + 3.0 D has a near addition of + 3.0 D and both TECNIS IOLs have a near addition of + 4.0 D. We evaluated the modulation transfer function area (MTFA) and the Strehl ratio. Additionally the optical qualities of the IOL were compared using USAF (United States Air Force)-Target pictures. Results The MTFA at the far focus (ReSTOR + 2.5 D/ReSTOR + 3.0 D/TECNIS) was 47.85/42.06/33.57. The MTFA was 11.05/9.54/8.60 for intermediate distances. MTFA at the near focus was 20.11/29.50/33.39. The Strehl ratio was 0.48/0.42/0.29 at the far focus, 0.11/0.10/0.09 at the intermediate focus and 0.20/0.30/0.34 at the near focus. The USAF Target pictures correlated with these measurements. Conclusion At the near focus, the TECNIS ZMA00 and ZMB00 performed the best, while the ReSTOR + 2.5 D performed the worst. At the intermediate distance, all IOLs achieved similar results. At the far focus, the ReSTOR + 2.5 D performed the best. Surgeons can choose the right IOL for the patientsʼ individual needs, because a broad range of near additions in diffractive multifocal IOLs is available these days.
- Open Access
- 29 June 2017
- Published by Springer Nature in BMC Ophthalmology
- Vol. 17 (1) , 1-9
In vitro optical quality measurements of three intraocular lens models having identical platform
With recent advances in technology and introduction of new intraocular lens (IOL) models, surgeons today have the opportunity to choose from various optical designs, which can influence the postoperative quality of vision. In our laboratory study, we compared the optical quality of three different IOLs that use the identical platform and are produced by the same manufacturer. The study included two diffractive multifocal IOLs, a bifocal and a trifocal one, as well as a monofocal IOL. Three IOL models: monofocal CT ASPHINA 409 M, diffractive bifocal AT LISA 809 M, and diffractive trifocal AT LISA Tri 839MP (Carl Zeiss Meditec AG, Germany) were assessed for optical quality by measuring modulation transfer function (MTF) and Strehl Ratio (SR) values at pupil sizes of 3.0 and 4.5 mm on the OptiSpheric® IOL PRO (Trioptics GmbH, Germany). The United States Air Force (USAF) Target images were also recorded to comfirm the optical performance qualitatively. For far focus at 50 lp/mm and 3.0 mm pupil size, MTF value of the monofocal lens (MTF = 0.798) was 1.8-fold and 2.1-fold better than the bifocal (MTF = 0.446) and the trifocal (MTF = 0.382) IOLs, respectively. For near focus, bifocal IOL (MTF = 0.265) was 1.4-fold better than trifocal IOL (MTF = 0.187), while for intermediate focus, the trifocal IOL (MTF = 0.148) was 1.7-fold better than the bifocal IOL (MTF = 0.086). For the same pupil size, total sum of light loss amounted to 5.2% for the monofocal, 16.0% for the bifocal and 6.0% for the trifocal IOL. For a larger pupil, the amount of light loss increased significantly for the multifocal IOLs. The monofocal IOL performed the best for far, the bifocal IOL for near and the trifocal IOL for intermediate focus. While the monofocal IOL created the least amount of light loss for both pupil sizes, the trifocal IOL created less than half the amount of light loss than the bifocal IOL for small pupil. For large pupil, however, less light scatter was observed for the bifocal than the trifocal IOL.
- 29 June 2017
- Published by Springer Nature in BMC Ophthalmology
- Vol. 17 (1) , 1-9
Open AccessIn vitro optical quality measurements of three intraocular lens models having identical platform
With recent advances in technology and introduction of new intraocular lens (IOL) models, surgeons today have the opportunity to choose from various optical designs, which can influence the postoperative quality of vision. In our laboratory study, we compared the optical quality of three different IOLs that use the identical platform and are produced by the same manufacturer. The study included two diffractive multifocal IOLs, a bifocal and a trifocal one, as well as a monofocal IOL. Three IOL models: monofocal CT ASPHINA 409 M, diffractive bifocal AT LISA 809 M, and diffractive trifocal AT LISA Tri 839MP (Carl Zeiss Meditec AG, Germany) were assessed for optical quality by measuring modulation transfer function (MTF) and Strehl Ratio (SR) values at pupil sizes of 3.0 and 4.5 mm on the OptiSpheric® IOL PRO (Trioptics GmbH, Germany). The United States Air Force (USAF) Target images were also recorded to comfirm the optical performance qualitatively. For far focus at 50 lp/mm and 3.0 mm pupil size, MTF value of the monofocal lens (MTF = 0.798) was 1.8-fold and 2.1-fold better than the bifocal (MTF = 0.446) and the trifocal (MTF = 0.382) IOLs, respectively. For near focus, bifocal IOL (MTF = 0.265) was 1.4-fold better than trifocal IOL (MTF = 0.187), while for intermediate focus, the trifocal IOL (MTF = 0.148) was 1.7-fold better than the bifocal IOL (MTF = 0.086). For the same pupil size, total sum of light loss amounted to 5.2% for the monofocal, 16.0% for the bifocal and 6.0% for the trifocal IOL. For a larger pupil, the amount of light loss increased significantly for the multifocal IOLs. The monofocal IOL performed the best for far, the bifocal IOL for near and the trifocal IOL for intermediate focus. While the monofocal IOL created the least amount of light loss for both pupil sizes, the trifocal IOL created less than half the amount of light loss than the bifocal IOL for small pupil. For large pupil, however, less light scatter was observed for the bifocal than the trifocal IOL.
- Open Access
- 8 February 2017
- Published by Springer Nature in BMC Ophthalmology
- Vol. 17 (1) , 9
In vitro comparative optical bench analysis of a spherical and aspheric optic design of the same IOL model
To analyse objective optical properties of the spherical and aspheric design of the same intraocular lens (IOL) model using optical bench analysis. This study entailed a comparative analysis of 10 spherical C-flex 570 C and 10 aspheric C-flex 970 C IOLs (Rayner Intraocular Lenses Ltd., Hove, UK) of 26 diopters [D] using an optical bench (OptiSpheric, Trioptics, Germany). In all lenses, we evaluated the modulation transfer function (MTF) at 50 lp/mm and 100 lp/mm and the Strehl Ratio using a 3-mm (photopic) and 4.5-mm (mesopic) aperture. At 50 lp/mm, the MTF values were 0.713/0.805 (C-flex 570 C/C-flex 970 C) for a 3-mm aperture and 0.294/0.591 for a 4.5-mm aperture. At 100 lp/mm, the MTF values were 0.524/0.634 for a 3-mm aperture and 0.198/0.344 for a 4.5-mm aperture. The Strehl Ratio was 0.806/0.925 and 0.237/0.479 for a 3-mm and 4.5-mm aperture respectively. A Mann–Whitney U test revealed all intergroup differences to be statistically significant (p < 0.01). The aspheric IOL design achieved higher MTF values than the spherical design of the same IOL for both apertures. Moreover, the differences between the two designs of the IOL were more prominent for larger apertures. This suggests that the evaluated IOL provides enhanced optical quality to patients with larger pupils or working under mesopic conditions.
- 8 February 2017
- Published by Springer Nature in BMC Ophthalmology
- Vol. 17 (1) , 9
Open AccessIn vitro comparative optical bench analysis of a spherical and aspheric optic design of the same IOL model
To analyse objective optical properties of the spherical and aspheric design of the same intraocular lens (IOL) model using optical bench analysis. This study entailed a comparative analysis of 10 spherical C-flex 570 C and 10 aspheric C-flex 970 C IOLs (Rayner Intraocular Lenses Ltd., Hove, UK) of 26 diopters [D] using an optical bench (OptiSpheric, Trioptics, Germany). In all lenses, we evaluated the modulation transfer function (MTF) at 50 lp/mm and 100 lp/mm and the Strehl Ratio using a 3-mm (photopic) and 4.5-mm (mesopic) aperture. At 50 lp/mm, the MTF values were 0.713/0.805 (C-flex 570 C/C-flex 970 C) for a 3-mm aperture and 0.294/0.591 for a 4.5-mm aperture. At 100 lp/mm, the MTF values were 0.524/0.634 for a 3-mm aperture and 0.198/0.344 for a 4.5-mm aperture. The Strehl Ratio was 0.806/0.925 and 0.237/0.479 for a 3-mm and 4.5-mm aperture respectively. A Mann–Whitney U test revealed all intergroup differences to be statistically significant (p < 0.01). The aspheric IOL design achieved higher MTF values than the spherical design of the same IOL for both apertures. Moreover, the differences between the two designs of the IOL were more prominent for larger apertures. This suggests that the evaluated IOL provides enhanced optical quality to patients with larger pupils or working under mesopic conditions.
- Open Access
- 18 August 2016
- Published by Wiley in Journal of Ophthalmology
- Vol. 2016, 1-2
Visual Rehabilitation in Combined Surgical Procedures: Bridging Two Eye Poles for Better Vision
- 18 August 2016
- Published by Wiley in Journal of Ophthalmology
- Vol. 2016, 1-2
Open AccessVisual Rehabilitation in Combined Surgical Procedures: Bridging Two Eye Poles for Better Vision
- Open Access
- 12 July 2016
- Published by Wiley in Journal of Ophthalmology
- Vol. 2016, 1-9
Impact of Indocyanine Green Concentration, Exposure Time, and Degree of Dissolution in Creating Toxic Anterior Segment Syndrome: Evaluation in a Rabbit Model
Purpose. To investigate the role of indocyanine green (ICG) dye as a causative material of toxic anterior segment syndrome (TASS) in an experimental rabbit model.Method. Eight eyes of four rabbits were allocated to this study. Capsular staining was performed using ICG dye, after which the anterior chamber was irrigated with a balanced salt solution. The effects of different concentrations (control, 0.25, 0.5, and 1.0%), exposure times (10 and 60 seconds), and the degree of dissolution (differently vortexed) were investigated. The analysis involved anterior segment photography, ultrasound pachymetry, prostaglandin assay (PGE2Parameter Assay, R&D systems, Inc.), and scanning electron microscopy of each iris.Result. There was no reaction in the control eye. A higher aqueous level of PGE2and more severe inflammatory reaction were observed in cases of eyes with higher concentration, longer exposure time, and poorly dissolved dye. Additionally, scanning electron microscopy revealed larger and coarser ICG particles.Conclusion. TASS occurrence may be associated with the concentration, exposure time, and degree of dissolution of ICG dye during cataract surgery.
- 12 July 2016
- Published by Wiley in Journal of Ophthalmology
- Vol. 2016, 1-9
Open AccessImpact of Indocyanine Green Concentration, Exposure Time, and Degree of Dissolution in Creating Toxic Anterior Segment Syndrome: Evaluation in a Rabbit Model
Purpose. To investigate the role of indocyanine green (ICG) dye as a causative material of toxic anterior segment syndrome (TASS) in an experimental rabbit model.Method. Eight eyes of four rabbits were allocated to this study. Capsular staining was performed using ICG dye, after which the anterior chamber was irrigated with a balanced salt solution. The effects of different concentrations (control, 0.25, 0.5, and 1.0%), exposure times (10 and 60 seconds), and the degree of dissolution (differently vortexed) were investigated. The analysis involved anterior segment photography, ultrasound pachymetry, prostaglandin assay (PGE2Parameter Assay, R&D systems, Inc.), and scanning electron microscopy of each iris.Result. There was no reaction in the control eye. A higher aqueous level of PGE2and more severe inflammatory reaction were observed in cases of eyes with higher concentration, longer exposure time, and poorly dissolved dye. Additionally, scanning electron microscopy revealed larger and coarser ICG particles.Conclusion. TASS occurrence may be associated with the concentration, exposure time, and degree of dissolution of ICG dye during cataract surgery.
- Open Access
- 3 April 2016
- Published by Hindawi Limited in Journal of Ophthalmology
- Vol. 2016, 1-6
In Vivo Imaging of Intraocular Fluidics in Vitrectomized Swine Eyes Using a Digital Fluoroscopy System
Purpose. To describe the characteristics of intraocular fluidics during cataract surgery in swine eyes with prior vitrectomy.Methods. We prepared three groups of enucleated swine eyes (nonvitrectomized, core, and totally vitrectomized). Irrigation and aspiration were performed (2.7 mm conventional sleeved phacosystem) using a balanced saline solution mixed with a water-soluble radiopaque contrast medium at 1 : 1 ratio. We imaged the eyes using a digital fluoroscopy system (DFS) during phacoemulsification and compared the characteristics of the intraocular fluid dynamics between the groups.Results. The anterior chamber depth (ACD) after the commencement of irrigation differed between groups ( mm; mm; mm), as well as the height of the fluid flowing from the anterior chamber into the posterior cavity that was identified by lifting up the iris to correct the infusion deviation syndrome ( mm; mm; mm).Conclusions. DFS demonstrated differences in fluid dynamics during phacoemulsification in swine eyes with or without prior vitrectomy. In completely vitrectomized eyes, the large ACD, which developed during phacoemulsification, could be reduced by lifting the iris and allowing the fluid to shift to the posterior cavity. Recognizing the differences in fluidics of vitrectomized eyes as compared to those of the nonvitrectomized eyes may reduce the frequency of intraoperative complications.- 3 April 2016
- Published by Hindawi Limited in Journal of Ophthalmology
- Vol. 2016, 1-6
Open AccessIn Vivo Imaging of Intraocular Fluidics in Vitrectomized Swine Eyes Using a Digital Fluoroscopy System
Purpose. To describe the characteristics of intraocular fluidics during cataract surgery in swine eyes with prior vitrectomy.Methods. We prepared three groups of enucleated swine eyes (nonvitrectomized, core, and totally vitrectomized). Irrigation and aspiration were performed (2.7 mm conventional sleeved phacosystem) using a balanced saline solution mixed with a water-soluble radiopaque contrast medium at 1 : 1 ratio. We imaged the eyes using a digital fluoroscopy system (DFS) during phacoemulsification and compared the characteristics of the intraocular fluid dynamics between the groups.Results. The anterior chamber depth (ACD) after the commencement of irrigation differed between groups ( mm; mm; mm), as well as the height of the fluid flowing from the anterior chamber into the posterior cavity that was identified by lifting up the iris to correct the infusion deviation syndrome ( mm; mm; mm).Conclusions. DFS demonstrated differences in fluid dynamics during phacoemulsification in swine eyes with or without prior vitrectomy. In completely vitrectomized eyes, the large ACD, which developed during phacoemulsification, could be reduced by lifting the iris and allowing the fluid to shift to the posterior cavity. Recognizing the differences in fluidics of vitrectomized eyes as compared to those of the nonvitrectomized eyes may reduce the frequency of intraoperative complications. - Open Access
- 25 November 2015
- Published by Springer Nature in BMC Ophthalmology
- Vol. 15 (1) , 1-7
Optical and material analysis of opacified hydrophilic intraocular lenses after explantation: a laboratory study
The opacification of hydrophilic intraocular lenses (IOLs) is a very rare complication in terms of absolute numbers. We report on the analyses of opacified Euromaxx ALI313Y and ALI313 IOLs (Argonoptics, Germany) using light and scanning electron microscopy, X-ray spectroscopy and optical bench analysis. Opacified Euromaxx ALI313Y and ALI313 IOLs were explanted after patients presented with a decrease in visual acuity. The explants were sent to our laboratory and examined using light and scanning electron microscopy. The composition of the deposits was analysed using X-ray spectroscopy. The optical quality of the intraocular lens (IOL) was assessed using the OptiSpheric IOL PRO optical bench (Trioptics GmbH Wedel, Germany). Modulation transfer function (MTF) was measured at all spatial frequencies and United States Air Force (USAF) 1951 resolution target pictures were documented. Macroscopically, the entire optic was opacified in all IOLs. Light and scanning electron microscopy revealed numerous fine, granular, crystalline-like deposits, which were always distributed in a line parallel to the anterior and posterior surfaces of the IOLs. X-ray spectroscopy could prove the deposits consisted of Calcium and Phosphate. Measurements in the optical bench showed deterioration of MTF values at all spatial frequencies and the USAF target pictures demonstrated a significant reduction of brightness as well as resolution with the opacified IOLs. The calcification of hydrophilic IOLs only occurs rarely. The exact chemical composition of the deposits can be assessed by means of X-ray spectroscopy. Optical quality analysis of the explanted Euromaxx ALI313Y and ALI313 IOLs showed significant reduction of MTF values, which was confirmed by USAF target pictures.
- 25 November 2015
- Published by Springer Nature in BMC Ophthalmology
- Vol. 15 (1) , 1-7
Open AccessOptical and material analysis of opacified hydrophilic intraocular lenses after explantation: a laboratory study
The opacification of hydrophilic intraocular lenses (IOLs) is a very rare complication in terms of absolute numbers. We report on the analyses of opacified Euromaxx ALI313Y and ALI313 IOLs (Argonoptics, Germany) using light and scanning electron microscopy, X-ray spectroscopy and optical bench analysis. Opacified Euromaxx ALI313Y and ALI313 IOLs were explanted after patients presented with a decrease in visual acuity. The explants were sent to our laboratory and examined using light and scanning electron microscopy. The composition of the deposits was analysed using X-ray spectroscopy. The optical quality of the intraocular lens (IOL) was assessed using the OptiSpheric IOL PRO optical bench (Trioptics GmbH Wedel, Germany). Modulation transfer function (MTF) was measured at all spatial frequencies and United States Air Force (USAF) 1951 resolution target pictures were documented. Macroscopically, the entire optic was opacified in all IOLs. Light and scanning electron microscopy revealed numerous fine, granular, crystalline-like deposits, which were always distributed in a line parallel to the anterior and posterior surfaces of the IOLs. X-ray spectroscopy could prove the deposits consisted of Calcium and Phosphate. Measurements in the optical bench showed deterioration of MTF values at all spatial frequencies and the USAF target pictures demonstrated a significant reduction of brightness as well as resolution with the opacified IOLs. The calcification of hydrophilic IOLs only occurs rarely. The exact chemical composition of the deposits can be assessed by means of X-ray spectroscopy. Optical quality analysis of the explanted Euromaxx ALI313Y and ALI313 IOLs showed significant reduction of MTF values, which was confirmed by USAF target pictures.