Three-dimensional US of the Fetus: Volume Imaging
Authors:
- Beryl R. BenacerrafBBBeryl R. Benacerraf
- Thomas D. ShippTSThomas D. Shipp
- Bryann BromleyBBBryann Bromley
- 1 March 2006
- journal article
- research article
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 238 (3) , 988-996
Abstract
To retrospectively compare the rapidity, efficiency, and accuracy of three-dimensional (3D) and two-dimensional (2D) ultrasonography (US) for complete anatomic survey in fetuses at 17-21 weeks of gestation. Institutional review board approval was obtained, informed consent was waived, and the study was HIPAA compliant. Fifty consecutive women undergoing fetal anatomic survey at 17-21 weeks of gestation formed the study cohort. After standard 2D US was performed by one of eight sonographers, the same sonographer also obtained five 3D volumes to encompass the entire fetal anatomy. Three physicians interpreting the scans independently evaluated the completeness of the examination and time needed to read the scans, comparing the standard 2D method with the 3D volume reconstruction technique. The paired t test was used to compare biparietal diameter (BPD), femur length, and performance times between the 3D measurements and the 2D measurement. The t test was used to compare fetal anatomy according to volume angle. Differences were significant when P < .05. Mean time to perform 2D US was 19.6 minutes per examination, whereas mean time to perform complete 3D volume acquisition was 1.8 minutes. Mean times needed to interpret 3D images and measure the BPD and femur were 5.53, 4.79, and 5.34 minutes for the three interpreting physicians. Compared with complete fetal surveys performed with 2D US, individual fetal anatomic landmarks (except for fetal arms and cavum septum pellucidum) were identified more than 94% of the time by using 3D US. Grouping anatomic views by region, the heart, head, extremities, and abdominal views were completely seen in 88%, 90%, 90%, and 95% of patients, respectively. No significant difference was seen between the three physicians regarding completeness of the 3D examinations (P = .7). One fetus had multiple anomalies, with 3D volumes identified as abnormal by all three physicians. Overall, 74% of 3D BPD measurements were within 1 mm of the 2D measurements, and 64% of 3D femur measurements were within 1 mm of the 2D measurements. The standard fetal anatomic survey can be performed in less than 2 minutes with 3D volume US, and the volumes can be interpreted in 6-7 minutes, compared with a mean of 19.6 minutes to perform standard 2D US.Keywords
This publication has 9 references indexed in Scilit:
- How Sonographic Tomography Will Change the Face of Obstetric SonographyJournal of Ultrasound in Medicine, 2005
- The future of ultrasound: viewing the dark side of the moon?Ultrasound in Obstetrics & Gynecology, 2004
- The prevalence of musculoskeletal symptoms among British Columbia sonographersApplied Ergonomics, 2002
- Three-dimensional Ultrasonographic Presentation of MicrognathiaJournal of Ultrasound in Medicine, 2002
- A Diagnostic Approach for the Evaluation of Spina Bifida by Three-dimensional UltrasonographyJournal of Ultrasound in Medicine, 2002
- Feasibility of performing a virtual patient examination using three‐dimensional ultrasonographic data acquired at remote locations.Journal of Ultrasound in Medicine, 2001
- Three‐dimensional ultrasonographic imaging in obstetrics: present and future applications.Journal of Ultrasound in Medicine, 2001
- Three‐dimensional ultrasound in the evaluation of fetal anomaliesUltrasound in Obstetrics & Gynecology, 2000
- Fetal face: What we can see using two-dimensional and three-dimensional ultrasound imagingSeminars in Roentgenology, 1998