Comparison of the corneal endothelial protective effects of Healon‐D and Viscoat
Authors:
- 1 May 2009
- journal article
- research article
- Published by Wiley in Clinical & Experimental Ophthalmology
- Vol. 37 (4) , 397-401
Abstract
Background: The use of dispersive ophthalmic viscosurgical devices (OVDs) has been shown to provide significant protection against air bubble damage to the corneal endothelium when compared with cohesive OVDs. We compared the corneal endothelial protective effects of a new dispersive OVD, Healon‐D, with Viscoat.Methods: Healon‐D and Viscoat were used in a randomized and masked fashion in the anterior chamber of 40 rabbit eyes during a procedure where ultrasound at 70% continuous energy was delivered for 2 min. Two millilitres of air bubbles were injected into the anterior chamber during the first minute of the procedure on each eye. Corneas were then stained with trypan blue and alizarin red and evaluated via light microscopy for endothelial injury. Both denuding of the endothelial layer, as well as damage to endothelial cells were quantified by using the Evaluation of Posterior Capsule Opacification digital imaging system.Results: The denuded area for eyes treated with Healon‐D and Viscoat were not significantly different (medians of 0.004167and 0.003333, respectively, P = 0.8908). There was no significant difference in the area of endothelial cell damaged (medians of 0.02183 and 0.01433, respectively, P = 0.4565). When the denuded and damaged areas were calculated together, there was also no difference in the total injured area (medians of 0.05817 and 0.05821, respectively, P = 0.5740).Conclusion: The new dispersive OVD Healon‐D is equally as effective as Viscoat in protecting the corneal endothelial layer from denuding and damage from air bubbles during anterior segment surgery.Keywords
This publication has 19 references indexed in Scilit:
- Corneal endothelial safety with the irradiation system for light-adjustable intraocular lensesJournal of Cataract & Refractive Surgery, 2007
- In vitro behavior of ophthalmic viscosurgical devices during phacoemulsificationJournal of Cataract & Refractive Surgery, 2006
- Quantitative assessment of ophthalmic viscosurgical device retention using in vivo confocal microscopyJournal of Cataract & Refractive Surgery, 2005
- New classification of ophthalmic viscosurgical devices—2005Journal of Cataract & Refractive Surgery, 2005
- Photographic image analysis system of posterior capsule opacificationJournal of Cataract & Refractive Surgery, 1997
- Protective effects of Healon and Occucoat against air bubble endothelial damage during ultrasonic agitation of the anterior chamberJournal of Cataract & Refractive Surgery, 1991
- Air bubble endothelial damage during phacoemulsification in human eye bank eyes: The protective effects of Healon and ViscoatJournal of Cataract & Refractive Surgery, 1990
- Endothelial Damage With Phacoemulsification and Intraocular Lens ImplantationArchives of Ophthalmology (1950), 1978
- Corneal Endothelial Damage Associated by PhacoemulsificationAmerican Journal of Ophthalmology, 1976
- Phaco-Emulsification and AspirationAmerican Journal of Ophthalmology, 1967