Liliana Werner
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Liliana Werner has a total of 306 co-authors. Here are the top co-authors by number of shared publications:
Nick Mamalis
Intermountain Ocular Research Center, Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, UT, USA
54 shared publications- Nick Mamalis
Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, UT, United States of America
8 shared publications Nathan Ellis
From the Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah (Bontu, Werner, Kennedy, Kamae, Jiang, Ellis, Mamalis), Salt Lake City, Utah, and LensGen (Brady), Irvine, California, USA
7 shared publicationsBill Jiang
From the Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah (Bontu, Werner, Kennedy, Kamae, Jiang, Ellis, Mamalis), Salt Lake City, Utah, and LensGen (Brady), Irvine, California, USA
6 shared publications- David J. Apple
Intermountain Ocular Research Center, John A Moran Eye Center, University of Utah, Salt Lake City, USA
6 shared publications Brian Hunter
Old Mill Medical Center
5 shared publications
Latest Publications
- Open Access
- 5 November 2026
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
Joint Assessment of Materials Exposure in Space: laboratory analyses of intraocular lenses after low-Earth-orbit exposure on the exterior of the International Space Station
Purpose: To evaluate effects of low Earth orbit (LEO) space conditions on intraocular lenses (IOLs) manufactured from different materials. Setting: International Space Station (ISS); Intermountain Ocular Research Center (John A. Moran Eye Center, University of Utah, Salt Lake City, Utah). Design: Experimental study. Methods: 135 IOLs made of hydrophobic acrylic, hydrophilic acrylic, and silicone materials were launched to the ISS as pressurized cargo. Of these, 61 were analyzed. On the ISS, the IOLs were placed in 3 external locations, differentiated by their exposure conditions: Ram (high atomic oxygen flux), Zenith (filtered UV-channel exposure), and Underdeck (external ISS environment with partial shielding). 45 corresponding controls remained on Earth. Of these, 20 were analyzed. After 6 months, the flight IOLs returned to Earth; 61 flight IOLs and 20 controls underwent gross and light microscopy. Changes were further assessed through scanning electron microscopy coupled with elemental analyses or spectrophotometry. Results: Postmission analysis of space-exposed IOLs demonstrated changes consistent with polymer erosion in 5 hydrophobic and 3 hydrophilic acrylic IOLs. 2 hydrophobic acrylic and 3 silicone lenses demonstrated yellow optic discoloration with changes in light transmission. These IOLs were all in the tray closest to exposure to Ram or Zenith conditions. All 6 space-exposed light-adjustable lenses in the 3 locations, with or without ActivShield, exhibited similar “cobblestone” changes on the anterior and posterior optic surfaces, as well as the optic edge. Conclusions: This exploratory study showed that IOL materials may differ in susceptibility to environmental hazards in LEO. These findings may inform packaging, shipping, and storage of IOLs in space because ophthalmic care will be required for future long-duration space missions and eventual extraterrestrial habitation.
- 5 November 2026
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
Open AccessJoint Assessment of Materials Exposure in Space: laboratory analyses of intraocular lenses after low-Earth-orbit exposure on the exterior of the International Space Station
Purpose: To evaluate effects of low Earth orbit (LEO) space conditions on intraocular lenses (IOLs) manufactured from different materials. Setting: International Space Station (ISS); Intermountain Ocular Research Center (John A. Moran Eye Center, University of Utah, Salt Lake City, Utah). Design: Experimental study. Methods: 135 IOLs made of hydrophobic acrylic, hydrophilic acrylic, and silicone materials were launched to the ISS as pressurized cargo. Of these, 61 were analyzed. On the ISS, the IOLs were placed in 3 external locations, differentiated by their exposure conditions: Ram (high atomic oxygen flux), Zenith (filtered UV-channel exposure), and Underdeck (external ISS environment with partial shielding). 45 corresponding controls remained on Earth. Of these, 20 were analyzed. After 6 months, the flight IOLs returned to Earth; 61 flight IOLs and 20 controls underwent gross and light microscopy. Changes were further assessed through scanning electron microscopy coupled with elemental analyses or spectrophotometry. Results: Postmission analysis of space-exposed IOLs demonstrated changes consistent with polymer erosion in 5 hydrophobic and 3 hydrophilic acrylic IOLs. 2 hydrophobic acrylic and 3 silicone lenses demonstrated yellow optic discoloration with changes in light transmission. These IOLs were all in the tray closest to exposure to Ram or Zenith conditions. All 6 space-exposed light-adjustable lenses in the 3 locations, with or without ActivShield, exhibited similar “cobblestone” changes on the anterior and posterior optic surfaces, as well as the optic edge. Conclusions: This exploratory study showed that IOL materials may differ in susceptibility to environmental hazards in LEO. These findings may inform packaging, shipping, and storage of IOLs in space because ophthalmic care will be required for future long-duration space missions and eventual extraterrestrial habitation.
- 13 August 2026
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 52 (11) , 1151
Dead bag syndrome associated with dislocated silicone intraocular lens
Was not provided for this article.
- 13 August 2026
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 52 (11) , 1151
Dead bag syndrome associated with dislocated silicone intraocular lens
Was not provided for this article.
- 15 July 2026
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
Clinical indications and microscopic findings in 151 explanted intraocular lenses over 12 years
Purpose: To analyze intraocular lenses (IOL) explanted at a single center between December 2012 and March 2025 with regard to explantation indications, patient demographics and light microscopic findings. Setting: Goethe University Frankfurt, and John A. Moran Eye Center, University of Utah. Design: Retrospective laboratory study. Methods: Explanted IOLs were catalogued according to patient demographics, intraocular duration, explantation indication and light microscopic appearance. When required, histochemical and histological staining was performed to further characterize observed deposits. Results: One hundred and fifty-one IOLs from 151 patients were examined. 87 of the patients were male (58%), 64 were female (42%). The mean patient age at explantation was 70.9 years ± 16.2 (standard deviation, SD), the mean intraocular duration was 10.5 years ± 8.1. Single-piece IOLs showed a predisposition to pigmentary dispersion, hydrophobic acrylic IOLs to glistenings and hydrophilic acrylic IOLs to calcification. Silicone IOLs demonstrated the highest rate of Soemmering’s ring (SR) traces within their capsular bag, although only in less advanced stages. Conclusions: The findings largely confirm the known material-specific susceptibility of IOLs to characteristic microscopic changes. Owing to its long observation period, this study reflects temporal changes in IOL material selection, model usage, and explantation indications over the past decades.
- 15 July 2026
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
Clinical indications and microscopic findings in 151 explanted intraocular lenses over 12 years
Purpose: To analyze intraocular lenses (IOL) explanted at a single center between December 2012 and March 2025 with regard to explantation indications, patient demographics and light microscopic findings. Setting: Goethe University Frankfurt, and John A. Moran Eye Center, University of Utah. Design: Retrospective laboratory study. Methods: Explanted IOLs were catalogued according to patient demographics, intraocular duration, explantation indication and light microscopic appearance. When required, histochemical and histological staining was performed to further characterize observed deposits. Results: One hundred and fifty-one IOLs from 151 patients were examined. 87 of the patients were male (58%), 64 were female (42%). The mean patient age at explantation was 70.9 years ± 16.2 (standard deviation, SD), the mean intraocular duration was 10.5 years ± 8.1. Single-piece IOLs showed a predisposition to pigmentary dispersion, hydrophobic acrylic IOLs to glistenings and hydrophilic acrylic IOLs to calcification. Silicone IOLs demonstrated the highest rate of Soemmering’s ring (SR) traces within their capsular bag, although only in less advanced stages. Conclusions: The findings largely confirm the known material-specific susceptibility of IOLs to characteristic microscopic changes. Owing to its long observation period, this study reflects temporal changes in IOL material selection, model usage, and explantation indications over the past decades.
- Open Access
- 1 January 2026
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery Online Case Reports
- Vol. 14
In-the-bag uveitis–glaucoma–hyphema syndrome caused by dead bag syndrome: case series
Introduction: Although out-of-the-bag uveitis–glaucoma–hyphema (UGH) syndrome is well described, to our knowledge, this is the first case series describing in-the-bag UGH syndrome with a posterior chamber lens completely within the capsular bag and no iris transillumination defect. This case series will describe disease presentation, pathologic findings, and treatment of in-the-bag UGH caused by dead bag syndrome (DBS). Patient and Clinical Findings: We present a case series of 3 patients diagnosed with in-the-bag UGH caused by DBS. All patients presented with bilateral DBS, pseudophacodonesis, and unilateral in-the-bag UGH in the left eye. Diagnosis, Intervention, and Outcomes: Ultrasound biomicroscopy (UBM) demonstrated uveal chafing by an in-the-bag IOL in all 3, confirming the diagnosis of in-the-bag UGH. 1 patient underwent intraocular lens (IOL) repositioning with scleral fixation, 1 patient underwent IOL exchange with scleral fixation, and the last patient was medically managed. Histopathological examination of the explanted IOL–bag complex of the second patient demonstrated features consistent with DBS. Pseudophacodonesis and UGH resolved with surgical intervention. In 2 of 3 patients, UGH resolved while on medical treatment but recurred when treatment was stopped. Conclusions: In-the-bag UGH caused by DBS is previously undescribed and currently diagnosed as idiopathic. Medical management may provide temporary control of uveitis, glaucoma, and hyphema. However, definitive management requires surgical intervention to fixate the IOL and eliminate uveal chafing. UBM imaging aids in the diagnosis of in-the-bag UGH by demonstrating uveal chafing caused by the mobile IOL.
- 1 January 2026
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery Online Case Reports
- Vol. 14
Open AccessIn-the-bag uveitis–glaucoma–hyphema syndrome caused by dead bag syndrome: case series
Introduction: Although out-of-the-bag uveitis–glaucoma–hyphema (UGH) syndrome is well described, to our knowledge, this is the first case series describing in-the-bag UGH syndrome with a posterior chamber lens completely within the capsular bag and no iris transillumination defect. This case series will describe disease presentation, pathologic findings, and treatment of in-the-bag UGH caused by dead bag syndrome (DBS). Patient and Clinical Findings: We present a case series of 3 patients diagnosed with in-the-bag UGH caused by DBS. All patients presented with bilateral DBS, pseudophacodonesis, and unilateral in-the-bag UGH in the left eye. Diagnosis, Intervention, and Outcomes: Ultrasound biomicroscopy (UBM) demonstrated uveal chafing by an in-the-bag IOL in all 3, confirming the diagnosis of in-the-bag UGH. 1 patient underwent intraocular lens (IOL) repositioning with scleral fixation, 1 patient underwent IOL exchange with scleral fixation, and the last patient was medically managed. Histopathological examination of the explanted IOL–bag complex of the second patient demonstrated features consistent with DBS. Pseudophacodonesis and UGH resolved with surgical intervention. In 2 of 3 patients, UGH resolved while on medical treatment but recurred when treatment was stopped. Conclusions: In-the-bag UGH caused by DBS is previously undescribed and currently diagnosed as idiopathic. Medical management may provide temporary control of uveitis, glaucoma, and hyphema. However, definitive management requires surgical intervention to fixate the IOL and eliminate uveal chafing. UBM imaging aids in the diagnosis of in-the-bag UGH by demonstrating uveal chafing caused by the mobile IOL.
- 1 January 2026
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 52 (1) , 109-110
Comment on: Intraocular ointment after phacoemulsification
- 1 January 2026
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 52 (1) , 109-110
Comment on: Intraocular ointment after phacoemulsification
- 1 November 2025
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 51 (11) , 1019-1025
Variations in morphology and patency of disposable hydrodissection cannulas used in cataract surgery
Purpose: To perform a detailed laboratory assessment of the variability in morphology (shape of opening port and surface finishing) and patency of Chang-style hydrodissection cannulas used in cataract surgery. Setting: John A. Moran Eye Center, University of Utah, Salt Lake City, Utah. Design: Experimental study. Methods: 44 disposable cannulas from 3 different manufacturers were evaluated in this study. 17 cannulas were primed with solution and then underwent analyses under gross and light microscopy. 27 other cannulas were directly removed from the package and underwent the same abovementioned analyses, before priming. Selected cannulas from the 3 manufacturers were also evaluated under scanning electron microscopy and surface analyses for elemental composition. Results: There was variability in all parameters evaluated in this study, including opening ports that were irregular in shape, partially or totally blocked, and a cannula with a second, lateral opening port. The surface finishing of the tips of the cannulas was also variable, with cannulas exhibiting irregular and/or sharp edges, as well as what seemed to be debris/residues. Fluid streams obtained with the cannulas also varied, and although some cannulas produced a normal stream, others produced a weak stream, no stream, or double stream. All cannulas were composed of stainless steel, and debris/residues seemed to correspond to organic residues. Conclusions: The findings in this study raise concerns about potential damage to the capsule and toxic anterior segment syndrome. Priming before use in surgery is advisable to confirm appropriate fluid flow.
- 1 November 2025
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 51 (11) , 1019-1025
Variations in morphology and patency of disposable hydrodissection cannulas used in cataract surgery
Purpose: To perform a detailed laboratory assessment of the variability in morphology (shape of opening port and surface finishing) and patency of Chang-style hydrodissection cannulas used in cataract surgery. Setting: John A. Moran Eye Center, University of Utah, Salt Lake City, Utah. Design: Experimental study. Methods: 44 disposable cannulas from 3 different manufacturers were evaluated in this study. 17 cannulas were primed with solution and then underwent analyses under gross and light microscopy. 27 other cannulas were directly removed from the package and underwent the same abovementioned analyses, before priming. Selected cannulas from the 3 manufacturers were also evaluated under scanning electron microscopy and surface analyses for elemental composition. Results: There was variability in all parameters evaluated in this study, including opening ports that were irregular in shape, partially or totally blocked, and a cannula with a second, lateral opening port. The surface finishing of the tips of the cannulas was also variable, with cannulas exhibiting irregular and/or sharp edges, as well as what seemed to be debris/residues. Fluid streams obtained with the cannulas also varied, and although some cannulas produced a normal stream, others produced a weak stream, no stream, or double stream. All cannulas were composed of stainless steel, and debris/residues seemed to correspond to organic residues. Conclusions: The findings in this study raise concerns about potential damage to the capsule and toxic anterior segment syndrome. Priming before use in surgery is advisable to confirm appropriate fluid flow.
- 1 February 2025
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 51 (2) , 126-132
Severe intraocular lens tilt after the Yamane technique
Purpose: To evaluate CT Lucia 602 intraocular lenses implanted in cases lacking capsular support and explanted because of decentration/dislocation with subsequent pathological analysis. The main objectives were to (1) document the status of haptics and (2) verify the presence of the rotisserie effect. Setting: John A. Moran Eye Center, University of Utah, Salt Lake City, Utah. Design: Case series with clinicopathological correlation. Methods: 13 explanted CT Lucia 602 lenses were included: 12 implanted by the Yamane technique and 1 that was iris-fixated. 4 lenses were explanted between October 2020 and February 2022. 9 lenses, explanted between November 2022 and February 2024, also exhibited severe optic tilt, leading to explantation. A chart review was performed to obtain clinical information from each case. Explanted lenses underwent gross and microscopic examination for haptic status and rotation, in the dry state (room temperature) and after hydration (body temperature). Results: Time between implantation and explantation was longer for lenses explanted before November 2022 (without severe tilt). Among the 26 haptics evaluated, 15 were deformed, 6 were broken, 2 were detached, and 3 were unremarkable. 4 haptics of Yamane lenses explanted between November 2022 and February 2024 showed free rotation within the optic insertion, after hydration at body temperature. Conclusions: Anecdotal reports of the rotisserie effect of CT Lucia 602 lenses implanted by the Yamane technique appeared mostly during the second half of 2022 and suggested that affected lenses were from specific batches, which seems to be consistent with the findings of this study.
- 1 February 2025
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 51 (2) , 126-132
Severe intraocular lens tilt after the Yamane technique
Purpose: To evaluate CT Lucia 602 intraocular lenses implanted in cases lacking capsular support and explanted because of decentration/dislocation with subsequent pathological analysis. The main objectives were to (1) document the status of haptics and (2) verify the presence of the rotisserie effect. Setting: John A. Moran Eye Center, University of Utah, Salt Lake City, Utah. Design: Case series with clinicopathological correlation. Methods: 13 explanted CT Lucia 602 lenses were included: 12 implanted by the Yamane technique and 1 that was iris-fixated. 4 lenses were explanted between October 2020 and February 2022. 9 lenses, explanted between November 2022 and February 2024, also exhibited severe optic tilt, leading to explantation. A chart review was performed to obtain clinical information from each case. Explanted lenses underwent gross and microscopic examination for haptic status and rotation, in the dry state (room temperature) and after hydration (body temperature). Results: Time between implantation and explantation was longer for lenses explanted before November 2022 (without severe tilt). Among the 26 haptics evaluated, 15 were deformed, 6 were broken, 2 were detached, and 3 were unremarkable. 4 haptics of Yamane lenses explanted between November 2022 and February 2024 showed free rotation within the optic insertion, after hydration at body temperature. Conclusions: Anecdotal reports of the rotisserie effect of CT Lucia 602 lenses implanted by the Yamane technique appeared mostly during the second half of 2022 and suggested that affected lenses were from specific batches, which seems to be consistent with the findings of this study.
- 21 January 2025
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 51 (4) , 323-331
Toxic Anterior Segment Syndrome: A 2012-2022 Update on the Most Common Causes
Purpose: To identify trends in the reporting of toxic anterior segment syndrome (TASS) to the American Society of Cataract and Refractive Surgery (ASCRS) TASS Force from 2012-2022. Setting: John A. Moran Eye Center, University of Utah, Salt Lake City, UT, USA. Design: Cross-sectional study. Methods: TASS questionnaires on instrument cleaning and sterilization, and extraocular and intraocular products used during cataract surgery were available on the American Society of Cataract and Refractive Surgery website. A retrospective analysis of questionnaires submitted by surgical centers reporting cases of TASS was performed between January 1, 2012, and December 31, 2022, to identify commonly held practices that could cause TASS. Results: Data from 77 questionnaires were analyzed. The reporting centers performed 56,319 cataract surgeries and reported 539 cases of TASS from January 1, 2012, to December 31, 2022. Common practices associated with the TASS outbreaks in the surveys included re-use of single-use cannulas, phacoemulsification, and irrigation/aspiration tips (69%), use of enzymatic cleaners (40%), inadequate flushing of phacoemulsification and irrigation/aspiration handpieces (27%), reuse of phacoemulsification tubing (22%), use of preservative-containing intracameral anesthetic (18%), and addition of antibiotics to balanced salt solution (17%). Conclusions: The surveys identified commonly held practices associated with TASS while showcasing trends over the past 10 years. Understanding these findings and the safe alternatives will allow surgical center personnel to change their practices as needed to prevent this complication.
- 21 January 2025
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 51 (4) , 323-331
Toxic Anterior Segment Syndrome: A 2012-2022 Update on the Most Common Causes
Purpose: To identify trends in the reporting of toxic anterior segment syndrome (TASS) to the American Society of Cataract and Refractive Surgery (ASCRS) TASS Force from 2012-2022. Setting: John A. Moran Eye Center, University of Utah, Salt Lake City, UT, USA. Design: Cross-sectional study. Methods: TASS questionnaires on instrument cleaning and sterilization, and extraocular and intraocular products used during cataract surgery were available on the American Society of Cataract and Refractive Surgery website. A retrospective analysis of questionnaires submitted by surgical centers reporting cases of TASS was performed between January 1, 2012, and December 31, 2022, to identify commonly held practices that could cause TASS. Results: Data from 77 questionnaires were analyzed. The reporting centers performed 56,319 cataract surgeries and reported 539 cases of TASS from January 1, 2012, to December 31, 2022. Common practices associated with the TASS outbreaks in the surveys included re-use of single-use cannulas, phacoemulsification, and irrigation/aspiration tips (69%), use of enzymatic cleaners (40%), inadequate flushing of phacoemulsification and irrigation/aspiration handpieces (27%), reuse of phacoemulsification tubing (22%), use of preservative-containing intracameral anesthetic (18%), and addition of antibiotics to balanced salt solution (17%). Conclusions: The surveys identified commonly held practices associated with TASS while showcasing trends over the past 10 years. Understanding these findings and the safe alternatives will allow surgical center personnel to change their practices as needed to prevent this complication.
- 1 September 2024
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 50 (9) , 970-975
3D X-ray computed tomography in the analyses of intraocular lenses explanted because of postoperative opacification
Purpose: To use X-ray computed tomography (CT) –which describes the acquisition and reconstruction of 2-dimensional X-ray transmission images to create a 3D representation of a specimen –in the analyses of intraocular lenses (IOLs) explanted because of optical opacification occurring postoperatively. Setting: John A. Moran Eye Center, and Utah Nanofab, University of Utah, Salt Lake City, Utah. Design: Laboratory study. Methods: A hydrophilic acrylic and a silicone lens (the latter from an eye with asteroid hyalosis) explanted because of postoperative calcification, as well as a poly(methyl methacrylate) (PMMA) lens explanted because of snowflake degeneration underwent analysis under gross and light microscopy. Then, they were attached to an appropriate support and scanned under a Zeiss Xradia Versa X-ray microscope. After data acquisition, data segmentation was performed with a commercially available program to separate image data into components. Results: Morphology, size/volume, and specific location of calcified deposits on the surface or within the substance of explanted IOLs could be demonstrated by X-ray CT within the entire volume of each lens with high contrast and resolution. The PMMA lens showed multiple spaces/fissures in relation to Nd:YAG pitting of the optic, and what appeared to be sheets of delaminated PMMA material at different levels within the optic substance. Conclusions: The key benefit of X-ray CT is that it can be performed without physically sectioning the specimen. This preliminary study demonstrates that this technology can be potentially useful in the imaging and analyses of explanted, opacified lenses.
- 1 September 2024
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 50 (9) , 970-975
3D X-ray computed tomography in the analyses of intraocular lenses explanted because of postoperative opacification
Purpose: To use X-ray computed tomography (CT) –which describes the acquisition and reconstruction of 2-dimensional X-ray transmission images to create a 3D representation of a specimen –in the analyses of intraocular lenses (IOLs) explanted because of optical opacification occurring postoperatively. Setting: John A. Moran Eye Center, and Utah Nanofab, University of Utah, Salt Lake City, Utah. Design: Laboratory study. Methods: A hydrophilic acrylic and a silicone lens (the latter from an eye with asteroid hyalosis) explanted because of postoperative calcification, as well as a poly(methyl methacrylate) (PMMA) lens explanted because of snowflake degeneration underwent analysis under gross and light microscopy. Then, they were attached to an appropriate support and scanned under a Zeiss Xradia Versa X-ray microscope. After data acquisition, data segmentation was performed with a commercially available program to separate image data into components. Results: Morphology, size/volume, and specific location of calcified deposits on the surface or within the substance of explanted IOLs could be demonstrated by X-ray CT within the entire volume of each lens with high contrast and resolution. The PMMA lens showed multiple spaces/fissures in relation to Nd:YAG pitting of the optic, and what appeared to be sheets of delaminated PMMA material at different levels within the optic substance. Conclusions: The key benefit of X-ray CT is that it can be performed without physically sectioning the specimen. This preliminary study demonstrates that this technology can be potentially useful in the imaging and analyses of explanted, opacified lenses.
- 1 March 2024
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 50 (3) , 289-294
Rotational stability of a new hydrophobic acrylic intraocular lens platform
Purpose: To evaluate rotational stability for ease of rotation of a new intraocular lens (IOL) platform with 4 haptics in an ex vivo model and compare it with a control single-piece lens with 2 open loops. Setting: Intermountain Ocular Research Center, John A. Moran Eye Center, University of Utah, Salt Lake City, Utah. Design: Experimental study. Methods: 10 human cadaver eyes were prepared as per the Miyake-Apple technique. After injection of the test or control lens, clockwise and counterclockwise rotations were attempted with a hook, with and without an ophthalmic viscosurgical device in place. Ease of rotation was scored as (1) very easy, (2) easy, (3) difficult, and (4) very difficult. Rotation of the entire eye containing test or control IOL was also performed with a multipurpose rotator (2 minutes; 220 revolutions per minute) to evaluate its effect on IOL alignment. Results: There were statistically significant differences regarding ease of rotation between test and control lenses in all 4 scenarios, with rotation being more difficult with the test lens (P < .05, Wilcoxon signed-rank test). No change in the alignment of test or control lenses was observed after eye rotation with the multipurpose rotator. Conclusions: The new IOL platform showed greater rotational stability than the control lens in this model, owing to design features such as 4 small arcs of contact between the haptics and the bag equator, a bulge at the distal end of each haptic, and arcuate haptics with curvatures oriented toward each other.
- 1 March 2024
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 50 (3) , 289-294
Rotational stability of a new hydrophobic acrylic intraocular lens platform
Purpose: To evaluate rotational stability for ease of rotation of a new intraocular lens (IOL) platform with 4 haptics in an ex vivo model and compare it with a control single-piece lens with 2 open loops. Setting: Intermountain Ocular Research Center, John A. Moran Eye Center, University of Utah, Salt Lake City, Utah. Design: Experimental study. Methods: 10 human cadaver eyes were prepared as per the Miyake-Apple technique. After injection of the test or control lens, clockwise and counterclockwise rotations were attempted with a hook, with and without an ophthalmic viscosurgical device in place. Ease of rotation was scored as (1) very easy, (2) easy, (3) difficult, and (4) very difficult. Rotation of the entire eye containing test or control IOL was also performed with a multipurpose rotator (2 minutes; 220 revolutions per minute) to evaluate its effect on IOL alignment. Results: There were statistically significant differences regarding ease of rotation between test and control lenses in all 4 scenarios, with rotation being more difficult with the test lens (P < .05, Wilcoxon signed-rank test). No change in the alignment of test or control lenses was observed after eye rotation with the multipurpose rotator. Conclusions: The new IOL platform showed greater rotational stability than the control lens in this model, owing to design features such as 4 small arcs of contact between the haptics and the bag equator, a bulge at the distal end of each haptic, and arcuate haptics with curvatures oriented toward each other.