The production of positron emitters with millisecond half-life during helium beam radiotherapy
- 1 December 2019
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 64 (23) , 235012
Abstract
Therapy with helium ions is currently receiving significantly increasing interest because helium ions have a sharper penumbra than protons and undergo less fragmentation than carbon ions and thus require less complicated dose calculations. For any ion of interest in hadron therapy, the accuracy of dose delivery is limited by range uncertainties. This has led to efforts by several groups to develop in vivo verification techniques, including positron emission tomography (PET), for monitoring of the dose delivery. Beam-on PET monitoring during proton therapy through the detection of short-lived positron emitters such as 12 N ( T 1/2 = 11 ms), an emerging PET technique, provides an attractive option given the achievable range accuracy, minimal susceptibility to biological washout and provision of near prompt feedback. Extension of this approach to helium ions requires information on the production yield of relevant short-lived positron emitters. This study presents the first measurements of the production of short-lived positron emitters in water, graphite, calcium and phosphorus targets irradiated with 59 MeV/u 3 He and 50 MeV/u 4 He beams. For these targets, the most produced short-lived nuclides are 13 O/ 12 N ( T 1/2 = 8.6/11 ms) on water, 13 O/ 12 N on graphite, 43 Ti/ 41 Sc/ 42 Sc ( T 1/2 = 509–680 ms) on calcium, 28 P ( T 1/2 = 268 ms) on phosphorus. A translation of the results from elemental targets to PMMA and representative tissues such as adipose tissue, muscle, compact and cortical bone, shows the dominance of 13 O/ 12 N in at least the first 20 s of an irradiation with 4 He and somewhat longer with 3 He. As the production of 13 O/ 12 N in a 3 He irradiation is 3–4 times higher than in a 4 He irradiation, from a statistical point of view, range verification using 13 O/ 12 N PET imaging will be about 2 times more precise for a 3 He irradiation compared to a 4 He irradiation.Keywords
This publication has 87 references indexed in Scilit:
- Nuclear Data Sheets for A = 29Nuclear Data Sheets, 2012
- Monitoring proton radiation therapy with in-room PET imagingPhysics in Medicine & Biology, 2011
- Proton therapy dosimetry using positron emission tomographyWorld Journal of Radiology, 2010
- Prompt gamma-ray emission from biological tissues during proton irradiation: a preliminary studyPhysics in Medicine & Biology, 2009
- Patient Study of In Vivo Verification of Beam Delivery and Range, Using Positron Emission Tomography and Computed Tomography Imaging After Proton TherapyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2007
- Acoustic pulse generated in a patient during treatment by pulsed proton radiation beamRadiation Oncology Investigations, 1995
- Yield and production of 18F by 3He irradiation of waterThe International Journal of Applied Radiation and Isotopes, 1977
- Yield of 18F for various reactions from oxygen and neonThe International Journal of Applied Radiation and Isotopes, 1974
- Total cross sections for the reaction 12C(3He, α)11C and 12C(3He, n)14ONuclear Physics, 1966
- Decay ofand the Levels ofPhysical Review B, 1963