Emiel R. van der Graaf
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Emiel R. van der Graaf has a total of 83 co-authors. Here are the top co-authors by number of shared publications:
- Sytze Brandenburg
KVI-Center for Advanced Radiation Technology, University of Groningen, Zernikelaan 25, 9747AA Groningen, The Netherlands
14 shared publications R.J. de Meijer
Department of Physics, University of the Western Cape, Private Bag X17, Bellville 7535, South Africa
10 shared publications- Peter Dendooven
Helsinki Institute of Physics, University of Helsinki, Helsinki, Finland
5 shared publications - Jun Takatsu
Department of Radiation Oncology, Juntendo University Graduate School of Medicine, Tokyo, Japan
4 shared publications J. Limburg
Medusa Radiometrics, Groningen, Skagerrak 26, 9723 JR, Groningen, the Netherlands
3 shared publicationsJ. Visser
National Institute for Subatomic Physics (Nikhef), Science Park 105, 1098 XG Amsterdam, the Netherlands
3 shared publications
Latest Publications
- Open Access
- 1 October 2021
- Published by Elsevier in Journal of Environmental Radioactivity
- Vol. 237, 106717
Optimizing gamma-ray spectrometers for UAV-borne surveys with geophysical applications
- 1 October 2021
- Published by Elsevier in Journal of Environmental Radioactivity
- Vol. 237, 106717
Open AccessOptimizing gamma-ray spectrometers for UAV-borne surveys with geophysical applications
- Open Access
- 1 May 2021
- Published by Elsevier in Journal of Environmental Radioactivity
- Vol. 231, 106545
Footprint and height corrections for UAV-borne gamma-ray spectrometry studies
- 1 May 2021
- Published by Elsevier in Journal of Environmental Radioactivity
- Vol. 231, 106545
Open AccessFootprint and height corrections for UAV-borne gamma-ray spectrometry studies
- Open Access
- 11 December 2020
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 65 (24) , 245013
Feasibility of quasi-prompt PET-based range verification in proton therapy
Compared to photon therapy, proton therapy allows a better conformation of the dose to the tumour volume with reduced radiation dose to co-irradiated tissues. Invivoverification techniques including Positron Emission Tomography (PET) have been proposed as quality assurance tools to mitigate proton range uncertainties. Detection of differences between planned and actual dose delivery on a short timescale provides a fast trigger for corrective actions. Conventional PET-based imaging of15O (T1/2= 2 min) and11C (T1/2= 20 min) distributions precludes such immediate feedback. We here present a demonstration of near real-time range verification by means of PET imaging of12N (T1/2= 11 ms). PMMA and graphite targets were irradiated with a 150 MeV proton pencil beam consisting of a series of pulses of 10 ms beam-on and 90 ms beam-off. Two modules of a modified Siemens Biograph mCT PET scanner (21 × 21 cm2each), installed 25 cm apart, were used to image the beam-induced PET activity during the beam-off periods. The modifications enable the detectors to be switched off during the beam-on periods.12N images were reconstructed using planar tomography. Using a 1D projection of the 2D reconstructed12N image, the activity range was obtained from a fit of the activity profile with a sigmoid function. Range shifts due to modified target configurations were assessed for multiples of the clinically relevant 108protons per pulse (approximately equal to the highest intensity spots in the pencil beam scanning delivery of a dose of 1 Gy over a cubic 1 liter volume). The standard deviation of the activity range, determined from 30 datasets obtained from three irradiations on PMMA and graphite targets, was found to be 2.5 and 2.6 mm (1σ) with 108protons per pulse and 0.9 and 0.8 mm (1σ) with 109protons per pulse. Analytical extrapolation of the results from this study shows that using a scanner with a solid angle coverage of 57%, with optimized detector switching and spot delivery times much smaller than the12N half-life, an activity range measurement precision of 2.0 mm (1σ) and 1.3 mm (1σ) within 50 milliseconds into an irradiation with 4 × 107and 108protons per pencil beam spot can be potentially realized. Aggregated imaging of neighbouring spots or, if possible, increasing the number of protons for a few probe beam spots will enable the realization of higher precision range measurement.
- 11 December 2020
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 65 (24) , 245013
Open AccessFeasibility of quasi-prompt PET-based range verification in proton therapy
Compared to photon therapy, proton therapy allows a better conformation of the dose to the tumour volume with reduced radiation dose to co-irradiated tissues. Invivoverification techniques including Positron Emission Tomography (PET) have been proposed as quality assurance tools to mitigate proton range uncertainties. Detection of differences between planned and actual dose delivery on a short timescale provides a fast trigger for corrective actions. Conventional PET-based imaging of15O (T1/2= 2 min) and11C (T1/2= 20 min) distributions precludes such immediate feedback. We here present a demonstration of near real-time range verification by means of PET imaging of12N (T1/2= 11 ms). PMMA and graphite targets were irradiated with a 150 MeV proton pencil beam consisting of a series of pulses of 10 ms beam-on and 90 ms beam-off. Two modules of a modified Siemens Biograph mCT PET scanner (21 × 21 cm2each), installed 25 cm apart, were used to image the beam-induced PET activity during the beam-off periods. The modifications enable the detectors to be switched off during the beam-on periods.12N images were reconstructed using planar tomography. Using a 1D projection of the 2D reconstructed12N image, the activity range was obtained from a fit of the activity profile with a sigmoid function. Range shifts due to modified target configurations were assessed for multiples of the clinically relevant 108protons per pulse (approximately equal to the highest intensity spots in the pencil beam scanning delivery of a dose of 1 Gy over a cubic 1 liter volume). The standard deviation of the activity range, determined from 30 datasets obtained from three irradiations on PMMA and graphite targets, was found to be 2.5 and 2.6 mm (1σ) with 108protons per pulse and 0.9 and 0.8 mm (1σ) with 109protons per pulse. Analytical extrapolation of the results from this study shows that using a scanner with a solid angle coverage of 57%, with optimized detector switching and spot delivery times much smaller than the12N half-life, an activity range measurement precision of 2.0 mm (1σ) and 1.3 mm (1σ) within 50 milliseconds into an irradiation with 4 × 107and 108protons per pencil beam spot can be potentially realized. Aggregated imaging of neighbouring spots or, if possible, increasing the number of protons for a few probe beam spots will enable the realization of higher precision range measurement.
- 1 December 2019
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 64 (23) , 235012
The production of positron emitters with millisecond half-life during helium beam radiotherapy
Therapy with helium ions is currently receiving significantly increasing interest because helium ions have a sharper penumbra than protons and undergo less fragmentation than carbon ions and thus require less complicated dose calculations. For any ion of interest in hadron therapy, the accuracy of dose delivery is limited by range uncertainties. This has led to efforts by several groups to develop in vivo verification techniques, including positron emission tomography (PET), for monitoring of the dose delivery. Beam-on PET monitoring during proton therapy through the detection of short-lived positron emitters such as 12 N ( T 1/2 = 11 ms), an emerging PET technique, provides an attractive option given the achievable range accuracy, minimal susceptibility to biological washout and provision of near prompt feedback. Extension of this approach to helium ions requires information on the production yield of relevant short-lived positron emitters. This study presents the first measurements of the production of short-lived positron emitters in water, graphite, calcium and phosphorus targets irradiated with 59 MeV/u 3 He and 50 MeV/u 4 He beams. For these targets, the most produced short-lived nuclides are 13 O/ 12 N ( T 1/2 = 8.6/11 ms) on water, 13 O/ 12 N on graphite, 43 Ti/ 41 Sc/ 42 Sc ( T 1/2 = 509–680 ms) on calcium, 28 P ( T 1/2 = 268 ms) on phosphorus. A translation of the results from elemental targets to PMMA and representative tissues such as adipose tissue, muscle, compact and cortical bone, shows the dominance of 13 O/ 12 N in at least the first 20 s of an irradiation with 4 He and somewhat longer with 3 He. As the production of 13 O/ 12 N in a 3 He irradiation is 3–4 times higher than in a 4 He irradiation, from a statistical point of view, range verification using 13 O/ 12 N PET imaging will be about 2 times more precise for a 3 He irradiation compared to a 4 He irradiation.
- 1 December 2019
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 64 (23) , 235012
The production of positron emitters with millisecond half-life during helium beam radiotherapy
Therapy with helium ions is currently receiving significantly increasing interest because helium ions have a sharper penumbra than protons and undergo less fragmentation than carbon ions and thus require less complicated dose calculations. For any ion of interest in hadron therapy, the accuracy of dose delivery is limited by range uncertainties. This has led to efforts by several groups to develop in vivo verification techniques, including positron emission tomography (PET), for monitoring of the dose delivery. Beam-on PET monitoring during proton therapy through the detection of short-lived positron emitters such as 12 N ( T 1/2 = 11 ms), an emerging PET technique, provides an attractive option given the achievable range accuracy, minimal susceptibility to biological washout and provision of near prompt feedback. Extension of this approach to helium ions requires information on the production yield of relevant short-lived positron emitters. This study presents the first measurements of the production of short-lived positron emitters in water, graphite, calcium and phosphorus targets irradiated with 59 MeV/u 3 He and 50 MeV/u 4 He beams. For these targets, the most produced short-lived nuclides are 13 O/ 12 N ( T 1/2 = 8.6/11 ms) on water, 13 O/ 12 N on graphite, 43 Ti/ 41 Sc/ 42 Sc ( T 1/2 = 509–680 ms) on calcium, 28 P ( T 1/2 = 268 ms) on phosphorus. A translation of the results from elemental targets to PMMA and representative tissues such as adipose tissue, muscle, compact and cortical bone, shows the dominance of 13 O/ 12 N in at least the first 20 s of an irradiation with 4 He and somewhat longer with 3 He. As the production of 13 O/ 12 N in a 3 He irradiation is 3–4 times higher than in a 4 He irradiation, from a statistical point of view, range verification using 13 O/ 12 N PET imaging will be about 2 times more precise for a 3 He irradiation compared to a 4 He irradiation.
- 1 August 2018
- Published by Elsevier in Physica Medica
- Vol. 52, 22
[OA054] Short-lived positron emitters for in-beam positron emission tomography (PET) verification of helium therapy
- 1 August 2018
- Published by Elsevier in Physica Medica
- Vol. 52, 22
[OA054] Short-lived positron emitters for in-beam positron emission tomography (PET) verification of helium therapy
- Open Access
- 1 February 2016
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 118, S10-S11
From 2D to 3D: Proton radiography and proton CT in proton therapy: A simulation study
- 1 February 2016
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 118, S10-S11
Open AccessFrom 2D to 3D: Proton radiography and proton CT in proton therapy: A simulation study
- 1 January 2016
- Published by Jagiellonian University in Acta Physica Polonica B
- Vol. 47 (2) , 329-334
Proton Radiography to Improve Proton Radiotherapy: Simulation Study at Different Proton Beam Energies
- 1 January 2016
- Published by Jagiellonian University in Acta Physica Polonica B
- Vol. 47 (2) , 329-334
Proton Radiography to Improve Proton Radiotherapy: Simulation Study at Different Proton Beam Energies
- 1 January 2016
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 11 (01) , C01004
Proton radiography to improve proton therapy treatment
The quality of cancer treatment with protons critically depends on an accurate prediction of the proton stopping powers for the tissues traversed by the protons. Today, treatment planning in proton radiotherapy is based on stopping power calculations from densities of X-ray Computed Tomography (CT) images. This causes systematic uncertainties in the calculated proton range in a patient of typically 3–4%, but can become even 10% in bone regions [1,2,3,4,5,6,7,8]. This may lead to no dose in parts of the tumor and too high dose in healthy tissues [1]. A direct measurement of proton stopping powers with high-energy protons will allow reducing these uncertainties and will improve the quality of the treatment. Several studies have shown that a sufficiently accurate radiograph can be obtained by tracking individual protons traversing a phantom (patient) [4,6,10]. Our studies benefit from the gas-filled time projection chambers based on GridPix technology [2], developed at Nikhef, capable of tracking a single proton. A BaF2 crystal measuring the residual energy of protons was used. Proton radiographs of phantom consisting of different tissue-like materials were measured with a 30×30 mm2 150 MeV proton beam. Measurements were simulated with the Geant4 toolkit.First experimental and simulated energy radiographs are in very good agreement [3]. In this paper we focus on simulation studies of the proton scattering angle as it affects the position resolution of the proton energy loss radiograph. By selecting protons with a small scattering angle, the image quality can be improved significantly.
- 1 January 2016
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 11 (01) , C01004
Proton radiography to improve proton therapy treatment
The quality of cancer treatment with protons critically depends on an accurate prediction of the proton stopping powers for the tissues traversed by the protons. Today, treatment planning in proton radiotherapy is based on stopping power calculations from densities of X-ray Computed Tomography (CT) images. This causes systematic uncertainties in the calculated proton range in a patient of typically 3–4%, but can become even 10% in bone regions [1,2,3,4,5,6,7,8]. This may lead to no dose in parts of the tumor and too high dose in healthy tissues [1]. A direct measurement of proton stopping powers with high-energy protons will allow reducing these uncertainties and will improve the quality of the treatment. Several studies have shown that a sufficiently accurate radiograph can be obtained by tracking individual protons traversing a phantom (patient) [4,6,10]. Our studies benefit from the gas-filled time projection chambers based on GridPix technology [2], developed at Nikhef, capable of tracking a single proton. A BaF2 crystal measuring the residual energy of protons was used. Proton radiographs of phantom consisting of different tissue-like materials were measured with a 30×30 mm2 150 MeV proton beam. Measurements were simulated with the Geant4 toolkit.First experimental and simulated energy radiographs are in very good agreement [3]. In this paper we focus on simulation studies of the proton scattering angle as it affects the position resolution of the proton energy loss radiograph. By selecting protons with a small scattering angle, the image quality can be improved significantly.
- 5 November 2015
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 60 (23) , 8923-8947
Short-lived positron emitters in beam-on PET imaging during proton therapy
The only method for in vivo dose delivery verification in proton beam radiotherapy in clinical use today is positron emission tomography (PET) of the positron emitters produced in the patient during irradiation. PET imaging while the beam is on (so called beam-on PET) is an attractive option, providing the largest number of counts, the least biological washout and the fastest feedback. In this implementation, all nuclides, independent of their half-life, will contribute. As a first step towards assessing the relevance of short-lived nuclides (half-life shorter than that of 10 C, T 1/2 = 19 s) for in vivo dose delivery verification using beam-on PET, we measured their production in the stopping of 55 MeV protons in water, carbon, phosphorus and calcium The most copiously produced short-lived nuclides and their production rates relative to the relevant long-lived nuclides are: 12 N ( T 1/2 = 11 ms) on carbon (9% of 11 C), 29 P ( T 1/2 = 4.1 s) on phosphorus (20% of 30 P) and 38m K ( T 1/2 = 0.92 s) on calcium (113% of 38g K). No short-lived nuclides are produced on oxygen. The number of decays integrated from the start of an irradiation as a function of time during the irradiation of PMMA and 4 tissue materials has been determined. For (carbon-rich) adipose tissue, 12 N dominates up to 70 s. On bone tissue, 12 N dominates over 15 O during the first 8–15 s (depending on carbon-to-oxygen ratio). The short-lived nuclides created on phosphorus and calcium provide 2.5 times more beam-on PET counts than the long-lived ones produced on these elements during a 70 s irradiation. From the estimated number of 12 N PET counts, we conclude that, for any tissue, 12 N PET imaging potentially provides equal to superior proton range information compared to prompt gamma imaging with an optimized knife-edge slit camera. The practical implementation of 12 N PET imaging is discussed.
- 5 November 2015
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 60 (23) , 8923-8947
Short-lived positron emitters in beam-on PET imaging during proton therapy
The only method for in vivo dose delivery verification in proton beam radiotherapy in clinical use today is positron emission tomography (PET) of the positron emitters produced in the patient during irradiation. PET imaging while the beam is on (so called beam-on PET) is an attractive option, providing the largest number of counts, the least biological washout and the fastest feedback. In this implementation, all nuclides, independent of their half-life, will contribute. As a first step towards assessing the relevance of short-lived nuclides (half-life shorter than that of 10 C, T 1/2 = 19 s) for in vivo dose delivery verification using beam-on PET, we measured their production in the stopping of 55 MeV protons in water, carbon, phosphorus and calcium The most copiously produced short-lived nuclides and their production rates relative to the relevant long-lived nuclides are: 12 N ( T 1/2 = 11 ms) on carbon (9% of 11 C), 29 P ( T 1/2 = 4.1 s) on phosphorus (20% of 30 P) and 38m K ( T 1/2 = 0.92 s) on calcium (113% of 38g K). No short-lived nuclides are produced on oxygen. The number of decays integrated from the start of an irradiation as a function of time during the irradiation of PMMA and 4 tissue materials has been determined. For (carbon-rich) adipose tissue, 12 N dominates up to 70 s. On bone tissue, 12 N dominates over 15 O during the first 8–15 s (depending on carbon-to-oxygen ratio). The short-lived nuclides created on phosphorus and calcium provide 2.5 times more beam-on PET counts than the long-lived ones produced on these elements during a 70 s irradiation. From the estimated number of 12 N PET counts, we conclude that, for any tissue, 12 N PET imaging potentially provides equal to superior proton range information compared to prompt gamma imaging with an optimized knife-edge slit camera. The practical implementation of 12 N PET imaging is discussed.
- 1 October 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-3
Influence of proton scattering angles on the energy radiograph in proton radiotherapy: A simulation study
The treatment quality of cancer patients with a proton beam critically depends on accurate predictions of proton stopping powers. Uncertainties in proton range that occur from translation of an X-ray CT patient image, of typical 3-4% or more, lead to necessary enlargements of contours around the tumor, and thus delivery of unnecessary dose to healthy tissues. A 2-dimentional proton radiography imaging technique, in which proton stopping powers of various materials (tissues) are measured directly, can improve quality of proton treatment. The proton scattering angle, causing the image degradation, has to be studied with a special care.
- 1 October 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-3
Influence of proton scattering angles on the energy radiograph in proton radiotherapy: A simulation study
The treatment quality of cancer patients with a proton beam critically depends on accurate predictions of proton stopping powers. Uncertainties in proton range that occur from translation of an X-ray CT patient image, of typical 3-4% or more, lead to necessary enlargements of contours around the tumor, and thus delivery of unnecessary dose to healthy tissues. A 2-dimentional proton radiography imaging technique, in which proton stopping powers of various materials (tissues) are measured directly, can improve quality of proton treatment. The proton scattering angle, causing the image degradation, has to be studied with a special care.