Dosimetric evaluation of VMAT treatment plans for patients with stage IIB or III non-small cell lung carcinomas
Authors:
- 31 May 2023
- journal article
- research article
- Published by Cambridge University Press (CUP) in Journal of Radiotherapy in Practice
- Vol. 22, e100
Abstract
Introduction: Volumetric-modulated arc therapy (VMAT) has emerged as a promising radiation treatment technique. One of the challenges in VMAT planning for lung carcinoma is the lack of consistency among different institutions with respect to what is considered an acceptable treatment plan in terms of target coverage and doses to the organs at risk (OAR). Additionally, the accuracy of dose calculations in the presence of heterogeneous medium (i.e. air) is another challenge in lung VMAT planning. Our objective is to develop an institutional criteria for non-stereotactic body radiotherapy (non-SBRT) lung treatment plans by evaluating the dosimetric impact of plan normalisation and dose calculation algorithms, including the Anisotropic Analytical Algorithm (AAA), AcurosXB (AXB) and Monte Carlo (MC) simulation, on VMAT plans for non-small cell lung cancer (NSCLC). Methods: The CT dataset of 20 patients with NSCLC was randomly selected to ensure a spectrum of target sizes and locations. All treatment planning was accomplished with 2–3 VMAT arcs and a prescription of 60 Gy in 30 fractions. Two plan normalisation methods were employed: (i) planning target volume (PTV) V100% = 95% and (ii) PTV V95% = 95%. Results: All three dose calculation algorithms revealed heterogeneous and conformal plans irrespective of plan normalisations. The PTV and OARs dose–volume constraints were met using both normalisation methods. However, we observed that AAA overestimated the minimum PTV doses by 2–5% regardless of plan normalisation. The mean PTV-V100% was lower for AAA in comparison with AXB and MC algorithms. Conclusions: VMAT is an effective radiotherapy technique for achieving greater target dose conformity, heterogeneity and dose fall-off from the PTV for the treatment of NSCLC. The results of this study can provide the basis for the development of local plan acceptability criteria for NSCLC VMAT plans, and the clinical implementation can be achieved with minimal or no imposition on resources and time constraints. Occasionally, plan normalisation of PTV-V95% = 95% may be required to ensure that the OAR dose tolerances are not exceeded.Keywords
This publication has 45 references indexed in Scilit:
- Surgery for nonsmall cell lung cancerEuropean Respiratory Review, 2013
- Dosimetric accuracy and clinical quality of Acuros XB and AAA dose calculation algorithm for stereotactic and conventional lung volumetric modulated arc therapy plansRadiation Oncology, 2013
- Combined Radio- and Chemotherapy for Non-Small Cell Lung Cancer: Systematic Review of Landmark Studies Based on Acquired CitationsFrontiers in Oncology, 2013
- Volumetric-Modulated Arc Therapy for Stereotactic Body Radiotherapy of Lung Tumors: A Comparison With Intensity-Modulated Radiotherapy TechniquesInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2011
- Planning analysis for locally advanced lung cancer: dosimetric and efficiency comparisons between intensity-modulated radiotherapy (IMRT), single-arc/partial-arc volumetric modulated arc therapy (SA/PA-VMAT)Radiation Oncology, 2011
- Sequential vs Concurrent Chemoradiation for Stage III Non-Small Cell Lung Cancer: Randomized Phase III Trial RTOG 9410JNCI: Journal of the National Cancer Institute, 2011
- Dosimetric evaluation of Acuros XB Advanced Dose Calculation algorithm in heterogeneous mediaRadiation Oncology, 2011
- Stereotactic Body Radiation Therapy for Inoperable Early Stage Lung CancerJAMA, 2010
- Quantitative Analyses of Normal Tissue Effects in the Clinic (QUANTEC): An Introduction to the Scientific IssuesInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2010
- Treatment of lung cancer using volumetric modulated arc therapy and image guidance: A case studyActa Oncologica, 2008