Comparison of Perpendicular to the Coronal Plane versus Medial Inclination for C2 Pedicle Screw Insertion Assisted by 3D Printed Navigation Template
Open Access
- 11 October 2022
- journal article
- research article
- Published by Wiley in Orthopaedic Surgery
- Vol. 15 (2) , 563-571
Abstract
Objective C2 pedicle screw insertion is very important in posterior upper cervical surgery. The traditional screw placement technique requires us to consider both medial inclination and cephalad angle, it is difficult to operate intraoperatively. This paper is to explore a novel method of C2 pedicle screw placement compared with traditional C2 pedicle screw. Methods A total of 44 patients diagnosed with atlantoaxial fracture or instability from May 2018 to November 2020 were involved in this retrospective study, and they were divided into C2-PPS group (perpendicular to the coronal plane C2 screw, 24 patients) and C2-TPS group (traditional C2 pedicle screw, 20 patients). The diameter of the maximum tangential circle, distance between geometric center and median sagittal plane and screw length of PPS and TPS were measured based on the 3D model of C2, respectively. Then the 3D printed navigation templated were designed and manufactured by 3D printing to assisted the PPS and TPS placement, respectively. The surgical time and radiation exposure times during operation were recorded; the post-operative grading criteria, deviation of screw entry point and deviation of screw angle of two groups were evaluated, respectively. Results A total of 48 screws were inserted in the C2-PPS group, and 40 screws were inserted in the C2-TPS group. There were 46 screws with grade 0 (95.8%) in the PPS group and 31 screws with grade 0 (77.5%) in the TPS group, (P = 0.03). The radiation exposure times in the C2-PPS group and C2-TPS group were 4.7 +/- 1.5 and 7.8 +/- 3.8, respectively, (P = 0.045). The deviations of screw entry point in the C2-PPS group and C2-TPS group were 1.2 +/- 0.8 mm and 3.2 +/- 1.3 mm, respectively; the deviations of screw angle in the C2-PPS group and C2-TPS group were 2.1 +/- 1.6 degrees and 4.8 +/- 2.0 degrees, respectively, (P = 0.000). The diameters of the maximum tangential circle in the C2-PPS group and C2-TPS group were 5.5 +/- 1.0 mm and 5.3 +/- 0.9 mm, respectively. The distances between the geometric center and median sagittal plane in the C2-PPS group and C2-TPS group were 15.4 +/- 2.3 mm and 18.0 +/- 3.3 mm, respectively; The screw lengths in the C2-PPS group and C2-TPS group were 25.9 +/- 3.2 mm and 27.6 +/- 3.7 mm, respectively, (P = 0.000). Conclusion Eighty percent of C2-PPS corridor can accommodate a 3.5 mm diameter screw, and with an average screw length of 26 mm. Navigation templates assisted the C2-PPS placement is less surgical time, less radiation exposure times, more safe and more accurate than C2-TPS.Keywords
This publication has 28 references indexed in Scilit:
- Análise tomográfica dos parâmetros anatômicos do áxis de criançasActa Ortopedica Brasileira, 2012
- Clinical application of C2 laminar screw techniqueEuropean Spine Journal, 2010
- Anatomical Considerations for Subaxial (C2) Pedicle Screw PlacementJournal of Spinal Disorders & Techniques, 2010
- C1–C2 Transarticular Screw Fixation for Atlantoaxial Instability due to Rheumatoid ArthritisSpine, 2009
- Outcomes of C1 and C2 posterior screw fixation for upper cervical spine fusionEuropean Spine Journal, 2009
- Posterior Screw Placement on the Lateral Mass of AtlasSpine, 2004
- Anatomic Consideration of C2 Pedicle Screw PlacementSpine, 1996
- Plate and screw fixation for atlanto-axial subluxationActa Neurochirurgica, 1994
- Stable Posterior Fusion of the Atlas and Axis by Transarticular Screw Fixation1987
- Treatment of pedicular fractures of the axisJournal of Neurosurgery, 1984