Tao Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Tao Li has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
Chao Wu
Orthopaedics, Zigong Fourth People's Hospital, Zigong, China.
8 shared publications- Chao Wu
Department of Orthopedics, Zigong Fourth People's Hospital, Zigong, China
6 shared publications Jiayan Deng
Institute of Digital Medicine Zigong Academy of Big Data for Medical Science and Artificial Intelligence Zigong 643000 China
6 shared publicationsXu Lin
Orthopaedics, Zigong Fourth People's Hospital, Zigong, China
5 shared publicationsLun Tan
Orthopedics Center of Zigong Fourth People’s Hospital, No. 19, Tanmulin street, Ziliujing district, Zigong, Sichuan Province, China
4 shared publicationsHai-Gang Hu
Orthopaedics of Zigong Fourth People’s Hospital, Zigong, Sichuan, China
3 shared publications
Latest Publications
- Open Access
- 14 July 2026
- Published by Springer Nature in European Spine Journal
- Vol. 35 (9) , 5731-5739
Radiograph-based intervertebral sagittal translation-to-canal diameter ratio as a quantitative imaging marker for suspected lower cervical instability
To compare radiographic differences between clinically suspected symptomatic lower cervical instability segments and asymptomatic normal segments and to evaluate the value of the radiograph-based intervertebral sagittal translation-to-canal diameter ratio (TCDR) as a quantitative imaging marker for lower cervical instability. This single-center retrospective study screened 197 clinically suspected cases of lower cervical instability. Seventeen cases with multilevel abnormalities but without a clearly identifiable clinically dominant responsible segment were excluded, leaving 180 patients with one clinically prespecified responsible segment. The control group included 60 asymptomatic examinees, with four segments from C3/4 to C6/7 measured in each participant. Group differences in intervertebral sagittal translation, radiographic sagittal canal diameter, intervertebral angulation, TCDR, and related indices were compared. ROC analysis, patient-cluster bootstrap, segment-stratified analysis, patient-level sensitivity analysis, cluster-robust logistic regression, and interobserver reliability analysis were performed. Age and sex did not differ between groups, but segment distribution differed significantly (P < 0.001). TCDR was higher in the study group than in controls (0.170 ± 0.066 vs. 0.067 ± 0.060, P < 0.001). The segment-level AUC of TCDR for lower cervical instability was 0.889 with an optimal cutoff of 0.087, 91.11% sensitivity, and 72.08% specificity. TCDR outperformed absolute intervertebral sagittal translation and intervertebral angulation, was positively correlated with instability (r = 0.631, P < 0.001), showed segment-specific AUCs of 0.811-0.929, and remained independently associated with lower cervical instability after adjustment (OR = 1.26, 95% CI 1.19-1.34, P < 0.001). Radiograph-based TCDR showed good segment-level discriminative ability for clinically suspected lower cervical instability and may serve as an adjunctive quantitative radiographic marker for assessing a responsible segment.
- 14 July 2026
- Published by Springer Nature in European Spine Journal
- Vol. 35 (9) , 5731-5739
Open AccessRadiograph-based intervertebral sagittal translation-to-canal diameter ratio as a quantitative imaging marker for suspected lower cervical instability
To compare radiographic differences between clinically suspected symptomatic lower cervical instability segments and asymptomatic normal segments and to evaluate the value of the radiograph-based intervertebral sagittal translation-to-canal diameter ratio (TCDR) as a quantitative imaging marker for lower cervical instability. This single-center retrospective study screened 197 clinically suspected cases of lower cervical instability. Seventeen cases with multilevel abnormalities but without a clearly identifiable clinically dominant responsible segment were excluded, leaving 180 patients with one clinically prespecified responsible segment. The control group included 60 asymptomatic examinees, with four segments from C3/4 to C6/7 measured in each participant. Group differences in intervertebral sagittal translation, radiographic sagittal canal diameter, intervertebral angulation, TCDR, and related indices were compared. ROC analysis, patient-cluster bootstrap, segment-stratified analysis, patient-level sensitivity analysis, cluster-robust logistic regression, and interobserver reliability analysis were performed. Age and sex did not differ between groups, but segment distribution differed significantly (P < 0.001). TCDR was higher in the study group than in controls (0.170 ± 0.066 vs. 0.067 ± 0.060, P < 0.001). The segment-level AUC of TCDR for lower cervical instability was 0.889 with an optimal cutoff of 0.087, 91.11% sensitivity, and 72.08% specificity. TCDR outperformed absolute intervertebral sagittal translation and intervertebral angulation, was positively correlated with instability (r = 0.631, P < 0.001), showed segment-specific AUCs of 0.811-0.929, and remained independently associated with lower cervical instability after adjustment (OR = 1.26, 95% CI 1.19-1.34, P < 0.001). Radiograph-based TCDR showed good segment-level discriminative ability for clinically suspected lower cervical instability and may serve as an adjunctive quantitative radiographic marker for assessing a responsible segment.
- 15 February 2026
- Vol. 40 (2) , 227-233
[Risk factor analysis of excessive resection of facet joint after large-channel spinal endoscopic depression for degenerative lumbar diseases].
To investigate the risk factors of facet joint excessive resection and its influence on effectiveness after the treatment of degenerative lumbar diseases under large-channel endoscope. The clinical data of 212 patients with degenerative lumbar diseases treated with large-channel spinal endoscopic technology between June 2022 and June 2024 were retrospectively analyzed. Among them, 120 were male and 92 were female. The age ranged from 18 to 85 years, with an average of 54 years. According to the facet joint resection rate measured by CT after operation, the patients were divided into preservation group (facet joint preservation rate≥50%) and excessive resection group (facet joint preservation rate1), distance between the base of the ipsilateral spinous process and the midline of the facet joint at the responsible segment (d 2), as well as the width (d 3) and height (d 4) of the interlaminar space at the responsible segment on anteroposterior X-ray films] between the preservation group and the excessive resection group. And logistic regression analysis was further used to identify risk factors for facet joint excessive resection. All patients underwent operative procedures successfully, and all incisions healed by first intention. No complication such as vascular and nerve injury, infection, and spinal cord hypertension-like syndrome occurred. There were 55 patients enrolled in the excessive resection group, and 157 patients in the preservation group. All patients were followed up 12-36 months, with a mean of 23.5 months. There was no significant difference in low back pain VAS score, leg pain VAS score, ODI, and JOA score between the two groups preoperatively ( P>0.05). The low back pain VAS score, ODI of the excessive resection group were significantly higher than those of the preservation group, and JOA score was significantly lower at 1 month after operation ( P<0.05), and there was no significant difference in the above indicators between the two groups at other time point ( P>0.05). At last follow-up, the effectiveness evaluated according to the modified MacNab assessment criteria was no significant difference between two groups ( Z=4.270, P=0.118). During the follow-up, 5 cases occurred lumbar instability in the excessive resection group and 4 cases in the preservation group, there was no significant difference between two groups ( χ 2=2.831, P=0.092). Univariate analysis showed that there were significant differences between the two groups in terms of age, gender, responsible segment, whether presence of lateral recess stenosis, FJA, d 1, d 2, laminar lateral-oblique angle, and d 3 ( P<0.05). Further logistic regression analysis showed that female patients, presence of lateral recess stenosis, FJA (≤45°), d 2 (≤11 mm), d 3 (≤21 mm) were risk factors for excessive resection of facet joint ( P<0.05). The incidence of excessive resection of facet joint in lumbar degenerative diseases treated by large-channel endoscopic depression reached 25.94% (55/212), and excessive resection of facet joint affects the recovery of lumbar pain and function in the short term after operation. Female patients, lateral recess stenosis, and FJA (≤45°), d 2 (≤11 mm), d 3 (≤21 mm) are risk factors for excessive resection of facet joint, which should be paid attention to in order to reduce the incidence of excessive resection of facet joint.
- 15 February 2026
- Vol. 40 (2) , 227-233
[Risk factor analysis of excessive resection of facet joint after large-channel spinal endoscopic depression for degenerative lumbar diseases].
To investigate the risk factors of facet joint excessive resection and its influence on effectiveness after the treatment of degenerative lumbar diseases under large-channel endoscope. The clinical data of 212 patients with degenerative lumbar diseases treated with large-channel spinal endoscopic technology between June 2022 and June 2024 were retrospectively analyzed. Among them, 120 were male and 92 were female. The age ranged from 18 to 85 years, with an average of 54 years. According to the facet joint resection rate measured by CT after operation, the patients were divided into preservation group (facet joint preservation rate≥50%) and excessive resection group (facet joint preservation rate1), distance between the base of the ipsilateral spinous process and the midline of the facet joint at the responsible segment (d 2), as well as the width (d 3) and height (d 4) of the interlaminar space at the responsible segment on anteroposterior X-ray films] between the preservation group and the excessive resection group. And logistic regression analysis was further used to identify risk factors for facet joint excessive resection. All patients underwent operative procedures successfully, and all incisions healed by first intention. No complication such as vascular and nerve injury, infection, and spinal cord hypertension-like syndrome occurred. There were 55 patients enrolled in the excessive resection group, and 157 patients in the preservation group. All patients were followed up 12-36 months, with a mean of 23.5 months. There was no significant difference in low back pain VAS score, leg pain VAS score, ODI, and JOA score between the two groups preoperatively ( P>0.05). The low back pain VAS score, ODI of the excessive resection group were significantly higher than those of the preservation group, and JOA score was significantly lower at 1 month after operation ( P<0.05), and there was no significant difference in the above indicators between the two groups at other time point ( P>0.05). At last follow-up, the effectiveness evaluated according to the modified MacNab assessment criteria was no significant difference between two groups ( Z=4.270, P=0.118). During the follow-up, 5 cases occurred lumbar instability in the excessive resection group and 4 cases in the preservation group, there was no significant difference between two groups ( χ 2=2.831, P=0.092). Univariate analysis showed that there were significant differences between the two groups in terms of age, gender, responsible segment, whether presence of lateral recess stenosis, FJA, d 1, d 2, laminar lateral-oblique angle, and d 3 ( P<0.05). Further logistic regression analysis showed that female patients, presence of lateral recess stenosis, FJA (≤45°), d 2 (≤11 mm), d 3 (≤21 mm) were risk factors for excessive resection of facet joint ( P<0.05). The incidence of excessive resection of facet joint in lumbar degenerative diseases treated by large-channel endoscopic depression reached 25.94% (55/212), and excessive resection of facet joint affects the recovery of lumbar pain and function in the short term after operation. Female patients, lateral recess stenosis, and FJA (≤45°), d 2 (≤11 mm), d 3 (≤21 mm) are risk factors for excessive resection of facet joint, which should be paid attention to in order to reduce the incidence of excessive resection of facet joint.
- Open Access
- 9 April 2025
- Published by Frontiers Media SA in Frontiers in Immunology
- Vol. 16, 1560570
The relationship between the composite dietary antioxidant index and rheumatoid arthritis risk in American adults: the mediating role of BMI
Background: The Clinical Dietary Antioxidant Index (CDAI) is a dietary antioxidant assessment index. Although CDAI has been shown to play a role in various chronic diseases, its association with rheumatoid arthritis (RA) remains underexplored. The aim of this study was to investigate the relationship between the CDAI and RA in U.S. adults, and to examine the mediating role of body mass index (BMI) in the relationship between CDAI and RA incidence.Methods: This cross-sectional study utilized data from the 2015–2023 National Health and Nutrition Examination Survey (NHANES). Weighted multivariate logistic regression models, restricted cubic spline (RCS) functions, and subgroup analyses were employed to examine the association between CDAI levels and RA in American adults. Mediation analysis was conducted to explore the mediating role of BMI in the relationship between CDAI and RA incidence.Results: A total of 13,288 participants were included, of whom 787 were diagnosed with RA, with a prevalence rate of 5.9%. Weighted multivariate logistic regression analyses across all four models showed a negative correlation between CDAI levels in the highest quartile and RA incidence. Restricted cubic spline curves revealed a non-linear negative association between CDAI, vitamin E, carotenoids, selenium, and RA incidence. As levels of CDAI, vitamin E, carotenoids, and selenium increased, the risk of RA decreased. Subgroup analyses and forest plots indicated significant associations between CDAI levels and RA across subgroups, including females, individuals aged over 60 years, Other Race - Including Multi-Racial groups, smokers, non-drinkers, individuals with heavy physical activity, hypertension, and BMI >25 (P < 0.05). Mediation analysis showed that BMI partially mediated the relationship between CDAI and RA, accounting for 10.88% of the effect.Conclusions: CDAI levels were negatively associated with RA incidence, particularly the components of CDAI such as vitamin E, carotenoids, and selenium. BMI mediated the relationship between CDAI and RA.
- 9 April 2025
- Published by Frontiers Media SA in Frontiers in Immunology
- Vol. 16, 1560570
Open AccessThe relationship between the composite dietary antioxidant index and rheumatoid arthritis risk in American adults: the mediating role of BMI
Background: The Clinical Dietary Antioxidant Index (CDAI) is a dietary antioxidant assessment index. Although CDAI has been shown to play a role in various chronic diseases, its association with rheumatoid arthritis (RA) remains underexplored. The aim of this study was to investigate the relationship between the CDAI and RA in U.S. adults, and to examine the mediating role of body mass index (BMI) in the relationship between CDAI and RA incidence.Methods: This cross-sectional study utilized data from the 2015–2023 National Health and Nutrition Examination Survey (NHANES). Weighted multivariate logistic regression models, restricted cubic spline (RCS) functions, and subgroup analyses were employed to examine the association between CDAI levels and RA in American adults. Mediation analysis was conducted to explore the mediating role of BMI in the relationship between CDAI and RA incidence.Results: A total of 13,288 participants were included, of whom 787 were diagnosed with RA, with a prevalence rate of 5.9%. Weighted multivariate logistic regression analyses across all four models showed a negative correlation between CDAI levels in the highest quartile and RA incidence. Restricted cubic spline curves revealed a non-linear negative association between CDAI, vitamin E, carotenoids, selenium, and RA incidence. As levels of CDAI, vitamin E, carotenoids, and selenium increased, the risk of RA decreased. Subgroup analyses and forest plots indicated significant associations between CDAI levels and RA across subgroups, including females, individuals aged over 60 years, Other Race - Including Multi-Racial groups, smokers, non-drinkers, individuals with heavy physical activity, hypertension, and BMI >25 (P < 0.05). Mediation analysis showed that BMI partially mediated the relationship between CDAI and RA, accounting for 10.88% of the effect.Conclusions: CDAI levels were negatively associated with RA incidence, particularly the components of CDAI such as vitamin E, carotenoids, and selenium. BMI mediated the relationship between CDAI and RA.
- Open Access
- 20 March 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-13
Association between body roundness index and osteoarthritis/rheumatoid arthritis: a cross-sectional study
To explore the relationship between the Body Roundness Index (BRI) and the prevalence of osteoarthritis (OA) and rheumatoid arthritis (RA) among American adults, providing new insights for identifying OA and RA in adults. We analyzed data from the National Health and Nutrition Examination Survey (NHANES) 2015–2023 and conducted a large cross-sectional study. BRI was calculated based on body measurements, while OA and RA cases were identified through questionnaires. Participants under 20 years of age and those with incomplete data were excluded. Weighted multivariate logistic regression models, restricted cubic spline (RCS) functions, and stratified analyses were used to assess the relationship between BRI levels and the prevalence of OA and RA in American adults. To further evaluate BRI’s diagnostic potential for OA and RA, receiver operating characteristic (ROC) curves were employed to analyze and calculate the area under the curve (AUC). After screening, 17,544 participants were included, with 2,382 cases of OA (13.58%) and 987 cases of RA (5.63%). Multivariate logistic regression analyses showed a positive correlation between BRI and OA prevalence in American adults in both the unadjusted and adjusted models. A similar correlation was observed for RA in the unadjusted and partially adjusted models (P < 0.001), but the fully adjusted model showed no significant association between BRI and RA (P > 0.05). In the unadjusted model, the prevalence of OA in the highest BRI quartile was 3.47 times than that of the lowest quartile (95% CI: 2.84, 4.24, P < 0.001). Even in the fully adjusted model, the prevalence of OA in the highest BRI quartile remained 1.46 times higher than that of the lowest quartile (95% CI: 1.02, 2.08, P < 0.05). RCS curves demonstrated a non-linear relationship between BRI and both OA and RA, with a significant increase in prevalence as BRI levels rose (P < 0.001). Subgroup analyses and forest plots indicated a positive correlation between BRI and OA and RA in most subgroups (P < 0.05). ROC curves showed that BRI had a better predictive ability for OA and RA risk compared to BMI. There is a significant positive correlation between BRI and the prevalence of OA and RA in American adults, especially OA. Maintaining a lower BRI may help prevent the onset of OA and RA.
- 20 March 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-13
Open AccessAssociation between body roundness index and osteoarthritis/rheumatoid arthritis: a cross-sectional study
To explore the relationship between the Body Roundness Index (BRI) and the prevalence of osteoarthritis (OA) and rheumatoid arthritis (RA) among American adults, providing new insights for identifying OA and RA in adults. We analyzed data from the National Health and Nutrition Examination Survey (NHANES) 2015–2023 and conducted a large cross-sectional study. BRI was calculated based on body measurements, while OA and RA cases were identified through questionnaires. Participants under 20 years of age and those with incomplete data were excluded. Weighted multivariate logistic regression models, restricted cubic spline (RCS) functions, and stratified analyses were used to assess the relationship between BRI levels and the prevalence of OA and RA in American adults. To further evaluate BRI’s diagnostic potential for OA and RA, receiver operating characteristic (ROC) curves were employed to analyze and calculate the area under the curve (AUC). After screening, 17,544 participants were included, with 2,382 cases of OA (13.58%) and 987 cases of RA (5.63%). Multivariate logistic regression analyses showed a positive correlation between BRI and OA prevalence in American adults in both the unadjusted and adjusted models. A similar correlation was observed for RA in the unadjusted and partially adjusted models (P < 0.001), but the fully adjusted model showed no significant association between BRI and RA (P > 0.05). In the unadjusted model, the prevalence of OA in the highest BRI quartile was 3.47 times than that of the lowest quartile (95% CI: 2.84, 4.24, P < 0.001). Even in the fully adjusted model, the prevalence of OA in the highest BRI quartile remained 1.46 times higher than that of the lowest quartile (95% CI: 1.02, 2.08, P < 0.05). RCS curves demonstrated a non-linear relationship between BRI and both OA and RA, with a significant increase in prevalence as BRI levels rose (P < 0.001). Subgroup analyses and forest plots indicated a positive correlation between BRI and OA and RA in most subgroups (P < 0.05). ROC curves showed that BRI had a better predictive ability for OA and RA risk compared to BMI. There is a significant positive correlation between BRI and the prevalence of OA and RA in American adults, especially OA. Maintaining a lower BRI may help prevent the onset of OA and RA.
- Open Access
- 15 February 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-9
Association between serum high-sensitivity C-reactive protein levels and osteoarthritis in adults from NHANES 2015 to 2018
To explore the association between serum high-sensitivity C-reactive protein (HSCRP) levels and osteoarthritis (OA) in adults, providing new evidence for the diagnosis of adult OA. We selected data from the 2015–2018 National Health and Nutrition Examination Survey (NHANES) and conducted a cross-sectional study. Serum HSCRP levels were extracted from laboratory data, and OA patients were identified through questionnaire responses. Participants under the age of 20 and those with incomplete data were excluded. We used multivariable logistic regression models, restricted cubic spline (RCS) functions, and stratified analyses to study the association between serum HSCRP levels and osteoarthritis in adults. After screening, a total of 9,948 participants were included, among whom 1,196 were osteoarthritis patients, representing a prevalence rate of 12.02%. Multivariable logistic regression analysis, along with three adjusted models, showed a positive correlation between serum HSCRP levels and the occurrence of osteoarthritis in adults. Compared to the lowest HSCRP quartile, the highest quartile showed a 1.86-fold higher prevalence of OA (95% confidence interval: 1.55 ~ 2.23, P < 0.001). The restricted cubic spline analysis showed a significant increase in OA incidence with rising serum HSCRP levels (P < 0.05). Subgroup and forest plot analyses indicated a positive correlation between HSCRP levels and osteoarthritis across different subgroups, such as age, gender, hypertension status, activity status, drinking status, and Smoke status (P < 0.05). There is a positive correlation between serum HSCRP levels and the occurrence of osteoarthritis in adults. When a patient’s serum HSCRP level is elevated, the possibility of osteoarthritis should be considered.
- 15 February 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-9
Open AccessAssociation between serum high-sensitivity C-reactive protein levels and osteoarthritis in adults from NHANES 2015 to 2018
To explore the association between serum high-sensitivity C-reactive protein (HSCRP) levels and osteoarthritis (OA) in adults, providing new evidence for the diagnosis of adult OA. We selected data from the 2015–2018 National Health and Nutrition Examination Survey (NHANES) and conducted a cross-sectional study. Serum HSCRP levels were extracted from laboratory data, and OA patients were identified through questionnaire responses. Participants under the age of 20 and those with incomplete data were excluded. We used multivariable logistic regression models, restricted cubic spline (RCS) functions, and stratified analyses to study the association between serum HSCRP levels and osteoarthritis in adults. After screening, a total of 9,948 participants were included, among whom 1,196 were osteoarthritis patients, representing a prevalence rate of 12.02%. Multivariable logistic regression analysis, along with three adjusted models, showed a positive correlation between serum HSCRP levels and the occurrence of osteoarthritis in adults. Compared to the lowest HSCRP quartile, the highest quartile showed a 1.86-fold higher prevalence of OA (95% confidence interval: 1.55 ~ 2.23, P < 0.001). The restricted cubic spline analysis showed a significant increase in OA incidence with rising serum HSCRP levels (P < 0.05). Subgroup and forest plot analyses indicated a positive correlation between HSCRP levels and osteoarthritis across different subgroups, such as age, gender, hypertension status, activity status, drinking status, and Smoke status (P < 0.05). There is a positive correlation between serum HSCRP levels and the occurrence of osteoarthritis in adults. When a patient’s serum HSCRP level is elevated, the possibility of osteoarthritis should be considered.
- Open Access
- 11 October 2022
- Published by Wiley in Orthopaedic Surgery
- Vol. 15 (2) , 563-571
Comparison of Perpendicular to the Coronal Plane versus Medial Inclination for C2 Pedicle Screw Insertion Assisted by 3D Printed Navigation Template
Objective C2 pedicle screw insertion is very important in posterior upper cervical surgery. The traditional screw placement technique requires us to consider both medial inclination and cephalad angle, it is difficult to operate intraoperatively. This paper is to explore a novel method of C2 pedicle screw placement compared with traditional C2 pedicle screw. Methods A total of 44 patients diagnosed with atlantoaxial fracture or instability from May 2018 to November 2020 were involved in this retrospective study, and they were divided into C2-PPS group (perpendicular to the coronal plane C2 screw, 24 patients) and C2-TPS group (traditional C2 pedicle screw, 20 patients). The diameter of the maximum tangential circle, distance between geometric center and median sagittal plane and screw length of PPS and TPS were measured based on the 3D model of C2, respectively. Then the 3D printed navigation templated were designed and manufactured by 3D printing to assisted the PPS and TPS placement, respectively. The surgical time and radiation exposure times during operation were recorded; the post-operative grading criteria, deviation of screw entry point and deviation of screw angle of two groups were evaluated, respectively. Results A total of 48 screws were inserted in the C2-PPS group, and 40 screws were inserted in the C2-TPS group. There were 46 screws with grade 0 (95.8%) in the PPS group and 31 screws with grade 0 (77.5%) in the TPS group, (P = 0.03). The radiation exposure times in the C2-PPS group and C2-TPS group were 4.7 +/- 1.5 and 7.8 +/- 3.8, respectively, (P = 0.045). The deviations of screw entry point in the C2-PPS group and C2-TPS group were 1.2 +/- 0.8 mm and 3.2 +/- 1.3 mm, respectively; the deviations of screw angle in the C2-PPS group and C2-TPS group were 2.1 +/- 1.6 degrees and 4.8 +/- 2.0 degrees, respectively, (P = 0.000). The diameters of the maximum tangential circle in the C2-PPS group and C2-TPS group were 5.5 +/- 1.0 mm and 5.3 +/- 0.9 mm, respectively. The distances between the geometric center and median sagittal plane in the C2-PPS group and C2-TPS group were 15.4 +/- 2.3 mm and 18.0 +/- 3.3 mm, respectively; The screw lengths in the C2-PPS group and C2-TPS group were 25.9 +/- 3.2 mm and 27.6 +/- 3.7 mm, respectively, (P = 0.000). Conclusion Eighty percent of C2-PPS corridor can accommodate a 3.5 mm diameter screw, and with an average screw length of 26 mm. Navigation templates assisted the C2-PPS placement is less surgical time, less radiation exposure times, more safe and more accurate than C2-TPS.
- 11 October 2022
- Published by Wiley in Orthopaedic Surgery
- Vol. 15 (2) , 563-571
Open AccessComparison of Perpendicular to the Coronal Plane versus Medial Inclination for C2 Pedicle Screw Insertion Assisted by 3D Printed Navigation Template
Objective C2 pedicle screw insertion is very important in posterior upper cervical surgery. The traditional screw placement technique requires us to consider both medial inclination and cephalad angle, it is difficult to operate intraoperatively. This paper is to explore a novel method of C2 pedicle screw placement compared with traditional C2 pedicle screw. Methods A total of 44 patients diagnosed with atlantoaxial fracture or instability from May 2018 to November 2020 were involved in this retrospective study, and they were divided into C2-PPS group (perpendicular to the coronal plane C2 screw, 24 patients) and C2-TPS group (traditional C2 pedicle screw, 20 patients). The diameter of the maximum tangential circle, distance between geometric center and median sagittal plane and screw length of PPS and TPS were measured based on the 3D model of C2, respectively. Then the 3D printed navigation templated were designed and manufactured by 3D printing to assisted the PPS and TPS placement, respectively. The surgical time and radiation exposure times during operation were recorded; the post-operative grading criteria, deviation of screw entry point and deviation of screw angle of two groups were evaluated, respectively. Results A total of 48 screws were inserted in the C2-PPS group, and 40 screws were inserted in the C2-TPS group. There were 46 screws with grade 0 (95.8%) in the PPS group and 31 screws with grade 0 (77.5%) in the TPS group, (P = 0.03). The radiation exposure times in the C2-PPS group and C2-TPS group were 4.7 +/- 1.5 and 7.8 +/- 3.8, respectively, (P = 0.045). The deviations of screw entry point in the C2-PPS group and C2-TPS group were 1.2 +/- 0.8 mm and 3.2 +/- 1.3 mm, respectively; the deviations of screw angle in the C2-PPS group and C2-TPS group were 2.1 +/- 1.6 degrees and 4.8 +/- 2.0 degrees, respectively, (P = 0.000). The diameters of the maximum tangential circle in the C2-PPS group and C2-TPS group were 5.5 +/- 1.0 mm and 5.3 +/- 0.9 mm, respectively. The distances between the geometric center and median sagittal plane in the C2-PPS group and C2-TPS group were 15.4 +/- 2.3 mm and 18.0 +/- 3.3 mm, respectively; The screw lengths in the C2-PPS group and C2-TPS group were 25.9 +/- 3.2 mm and 27.6 +/- 3.7 mm, respectively, (P = 0.000). Conclusion Eighty percent of C2-PPS corridor can accommodate a 3.5 mm diameter screw, and with an average screw length of 26 mm. Navigation templates assisted the C2-PPS placement is less surgical time, less radiation exposure times, more safe and more accurate than C2-TPS.
- 6 July 2021
- Published by Taylor & Francis in Neurological Research
- Vol. 43 (12) , 961-969
Three-dimensional anatomic analysis and navigation templates for C1 pedicle screw placement perpendicular to the coronal plane: a retrospective study
To explore the corridor for atlas pedicle screw placement perpendicular to the coronal plane and to develop patient-specific navigation templates for pedicle screw placement.This study is a retrosp...
- 6 July 2021
- Published by Taylor & Francis in Neurological Research
- Vol. 43 (12) , 961-969
Three-dimensional anatomic analysis and navigation templates for C1 pedicle screw placement perpendicular to the coronal plane: a retrospective study
To explore the corridor for atlas pedicle screw placement perpendicular to the coronal plane and to develop patient-specific navigation templates for pedicle screw placement.This study is a retrosp...
- 15 June 2021
- Vol. 35 (6) , 742-749
3D 打印皮外导板辅助微创椎弓根螺钉植入治疗多节段胸腰椎骨折
评价 3D 打印皮外导板辅助经皮椎弓根螺钉植入治疗多节段胸腰椎骨折的可行性和安全性。 回顾分析 2017 年 5 月—2019 年 1 月手术治疗的 19 例无神经损伤多节段胸腰椎骨折患者临床资料。其中男 9 例,女 10 例;年龄 22~63 岁,平均 43.6 岁。致伤原因:交通事故伤 12 例,高处坠落伤 7 例。骨折椎体涉及 T10~L3 共 40 个,单个椎体骨折按 AO 分型:A1 型 29 个,A2 型 9 个,A3 型 2 个;多节段胸腰椎骨折按唐三元分型:ⅠA 型 17 例,ⅠB 型 1 例,ⅡC 型 1 例。受伤至手术时间 2~6 d,平均 3.1 d。术中采用 3D 打印皮外导板辅助经皮椎弓根螺钉植入。记录术中出血量、平均每枚螺钉植入手术时间和透射次数;术前、术后 3 d 及末次随访时采用疼痛视觉模拟评分(VAS)评价腰痛改善情况。根据术后 3 d CT 采用 Gertzbein 和 Robbins 量表评价植钉准确性(A、B 级为植钉准确,A 级为植钉优秀),测量骨折节段矢状面 Cobb 角,计算伤椎前缘高度百分比;测量术后双侧椎弓根螺钉内倾角差值,分析其一致性,并与术中选用皮外导板的角度进行对比,以验证皮外导板控制内倾角的有效性。 19 例患者均顺利完成手术,术中出血量 44~67 mL,平均 54.3 mL;平均每枚螺钉植入手术时间 7.3~11.1 min,平均 9.6 min;平均每枚螺钉植入透射次数 1.6~2.5 次,平均 2.0 次。无脊髓、神经根损伤及感染等并发症发生。患者均获随访,随访时间 24~38 个月,平均 28.7 个月。采用 Gertzbein 和 Robbins 量表评价植钉准确性:A 级 145 枚,B 级 11 枚;植钉准确率达 100%,优秀率 92.9%。术后 3 d CT 测量示同椎体左、右侧螺钉内倾角差异无统计学意义(t=0.93,P=0.36);术中选用皮外导板的内倾角与螺钉内倾角比较差异均无统计学意义(P>0.05)。患者术后 3 d 与末次随访时腰痛 VAS 评分、矢状面 Cobb 角及伤椎前缘高度百分比均较术前显著改善,末次随访时腰痛 VAS 评分较术后 3 d 进一步改善(P0.05)。所有患者末次随访时均未见内固定物松动、断裂,骨折均愈合良好。 使用 3D 打印皮外导板辅助经皮椎弓根螺钉植入治疗多节段胸腰椎骨折,可减少手术时间、术中出血量及透视次数,植钉准确,有较好的复位效果。
- 15 June 2021
- Vol. 35 (6) , 742-749
3D 打印皮外导板辅助微创椎弓根螺钉植入治疗多节段胸腰椎骨折
评价 3D 打印皮外导板辅助经皮椎弓根螺钉植入治疗多节段胸腰椎骨折的可行性和安全性。 回顾分析 2017 年 5 月—2019 年 1 月手术治疗的 19 例无神经损伤多节段胸腰椎骨折患者临床资料。其中男 9 例,女 10 例;年龄 22~63 岁,平均 43.6 岁。致伤原因:交通事故伤 12 例,高处坠落伤 7 例。骨折椎体涉及 T10~L3 共 40 个,单个椎体骨折按 AO 分型:A1 型 29 个,A2 型 9 个,A3 型 2 个;多节段胸腰椎骨折按唐三元分型:ⅠA 型 17 例,ⅠB 型 1 例,ⅡC 型 1 例。受伤至手术时间 2~6 d,平均 3.1 d。术中采用 3D 打印皮外导板辅助经皮椎弓根螺钉植入。记录术中出血量、平均每枚螺钉植入手术时间和透射次数;术前、术后 3 d 及末次随访时采用疼痛视觉模拟评分(VAS)评价腰痛改善情况。根据术后 3 d CT 采用 Gertzbein 和 Robbins 量表评价植钉准确性(A、B 级为植钉准确,A 级为植钉优秀),测量骨折节段矢状面 Cobb 角,计算伤椎前缘高度百分比;测量术后双侧椎弓根螺钉内倾角差值,分析其一致性,并与术中选用皮外导板的角度进行对比,以验证皮外导板控制内倾角的有效性。 19 例患者均顺利完成手术,术中出血量 44~67 mL,平均 54.3 mL;平均每枚螺钉植入手术时间 7.3~11.1 min,平均 9.6 min;平均每枚螺钉植入透射次数 1.6~2.5 次,平均 2.0 次。无脊髓、神经根损伤及感染等并发症发生。患者均获随访,随访时间 24~38 个月,平均 28.7 个月。采用 Gertzbein 和 Robbins 量表评价植钉准确性:A 级 145 枚,B 级 11 枚;植钉准确率达 100%,优秀率 92.9%。术后 3 d CT 测量示同椎体左、右侧螺钉内倾角差异无统计学意义(t=0.93,P=0.36);术中选用皮外导板的内倾角与螺钉内倾角比较差异均无统计学意义(P>0.05)。患者术后 3 d 与末次随访时腰痛 VAS 评分、矢状面 Cobb 角及伤椎前缘高度百分比均较术前显著改善,末次随访时腰痛 VAS 评分较术后 3 d 进一步改善(P0.05)。所有患者末次随访时均未见内固定物松动、断裂,骨折均愈合良好。 使用 3D 打印皮外导板辅助经皮椎弓根螺钉植入治疗多节段胸腰椎骨折,可减少手术时间、术中出血量及透视次数,植钉准确,有较好的复位效果。
- Open Access
- 7 April 2021
- Published by Wiley in Orthopaedic Surgery
- Vol. 13 (3) , 1006-1015
3D‐Printed Screw‐Rod Auxiliary System for Unstable Atlas Fractures: A Retrospective Analysis
Objective: To develop and validate the efficacy of a 3D‐printed screw‐rod auxiliary system for unstable atlas fractures.Methods: This research is a retrospective analysis, and a total of 14 patients, including 11 males and three females, were enrolled in our hospital from January 2017 to March 2019 who underwent occipitocervical fusion assisted by the 3D‐printed screw‐rod auxiliary system were reviewed, and with an average age of 53.21 ± 14.81 years, an average body mass index (BMI) of 23.61 ± 1.93 kg/m2. The operation time, blood loss and radiation times during the operation were recorded. The maximum fracture displacement values of pre‐ and post‐operation were measured based on CT imaging. All screw grades were evaluated after surgery. The occipital‐cervical 2 (O‐C2) angle and occipitocervical inclination (OCI) angle of pre‐operation, post‐operation and the last following‐up were measured. The dysphagia scale 3 months after surgery and at the last follow‐up, the Neck Disability Index (NDI) 3 months after surgery and at the last follow‐up were assessed.Results: All patients were completed the surgery successfully. There was no patient with severe dysphagia or aggravation of nerve injury. The follow‐up was from 12 to 14 months, and with an average of 12.5 months. The average surgery time, average blood loss and average radiation times for the 14 patients were 112.14 min, 171.43 mL and 5.07 times, respectively. There was a significant difference in maximum fracture displacement between pre‐ and post‐operation values (P < 0.05). A total of 56 screws were inserted in 14 patients, among them, three screws were classified as grade 1, and the other screws were classified as grade 0. There was a significant difference in the O‐C2 between pre‐operation and 3 days after operation (P = 0.002); There was a significant difference in OCI angles between pre‐operation and 3 days after operation (P < 0.05); there was no significant difference in the O‐C2 or OCI angle between 3 days after the operation and the last follow‐up (P = 0.079; P = 0.201). The dysphagia scales of two patients were assessed as mild at 3 months after surgery, and the others were assessed as normal at 3 months after surgery. All patients' dysphagia scores returned to normal at the last follow‐up. The average NDI and average neck Visual Analogue Scale (VAS) scores at the last follow‐up were 2.53 and 8.41, respectively.Conclusion: It can objectively restore the OCI to normal with few post‐operative complications under the assistance of a screw‐rod auxiliary system to perform occipitocervical fusion for unstable atlas fractures and atlantooccipital joint instability.
- 7 April 2021
- Published by Wiley in Orthopaedic Surgery
- Vol. 13 (3) , 1006-1015
Open Access3D‐Printed Screw‐Rod Auxiliary System for Unstable Atlas Fractures: A Retrospective Analysis
Objective: To develop and validate the efficacy of a 3D‐printed screw‐rod auxiliary system for unstable atlas fractures.Methods: This research is a retrospective analysis, and a total of 14 patients, including 11 males and three females, were enrolled in our hospital from January 2017 to March 2019 who underwent occipitocervical fusion assisted by the 3D‐printed screw‐rod auxiliary system were reviewed, and with an average age of 53.21 ± 14.81 years, an average body mass index (BMI) of 23.61 ± 1.93 kg/m2. The operation time, blood loss and radiation times during the operation were recorded. The maximum fracture displacement values of pre‐ and post‐operation were measured based on CT imaging. All screw grades were evaluated after surgery. The occipital‐cervical 2 (O‐C2) angle and occipitocervical inclination (OCI) angle of pre‐operation, post‐operation and the last following‐up were measured. The dysphagia scale 3 months after surgery and at the last follow‐up, the Neck Disability Index (NDI) 3 months after surgery and at the last follow‐up were assessed.Results: All patients were completed the surgery successfully. There was no patient with severe dysphagia or aggravation of nerve injury. The follow‐up was from 12 to 14 months, and with an average of 12.5 months. The average surgery time, average blood loss and average radiation times for the 14 patients were 112.14 min, 171.43 mL and 5.07 times, respectively. There was a significant difference in maximum fracture displacement between pre‐ and post‐operation values (P < 0.05). A total of 56 screws were inserted in 14 patients, among them, three screws were classified as grade 1, and the other screws were classified as grade 0. There was a significant difference in the O‐C2 between pre‐operation and 3 days after operation (P = 0.002); There was a significant difference in OCI angles between pre‐operation and 3 days after operation (P < 0.05); there was no significant difference in the O‐C2 or OCI angle between 3 days after the operation and the last follow‐up (P = 0.079; P = 0.201). The dysphagia scales of two patients were assessed as mild at 3 months after surgery, and the others were assessed as normal at 3 months after surgery. All patients' dysphagia scores returned to normal at the last follow‐up. The average NDI and average neck Visual Analogue Scale (VAS) scores at the last follow‐up were 2.53 and 8.41, respectively.Conclusion: It can objectively restore the OCI to normal with few post‐operative complications under the assistance of a screw‐rod auxiliary system to perform occipitocervical fusion for unstable atlas fractures and atlantooccipital joint instability.
- Open Access
- 13 July 2020
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 15 (1) , 1-11
Anatomical conditions and patient-specific locked navigation templates for transverse sacroiliac screw placement: a retrospective study
Objective: To analyse the anatomical conditions of transverse sacroiliac screw (TSS) about the S1 and S2 segments in order to develop and validate a locked navigational template for TSS placement. Methods: A total of 22 patients with sacral fractures were involved in this study from May 2018 to February 2019. Patients were divided into two groups according to the surgery procedure: locked template group and conventional group. The CT data of 90 normal sacra were analysed. The long axis, short axis and lengths of TSS, cancellous corridors were measured through 3D modelling. A patient-specific locked navigation template based on simulated screws was designed and 3D printed and then used to assist in TSS placement. The operative time and radiation times were recorded. The Matta criteria and grading score were evaluated. The entry point deviation of the actual screw placement relative to the simulated screw placement was measured, and whether the whole screw was in the cancellous corridor was ob`served. Results: S1 screws with a diameter of 7.3 mm could be inserted into 69 pelvises, and S2 screws could be inserted in all pelvises. The S1 cancellous corridor had a long axis of 25.44 ± 3.32 mm in males and 22.91 ± 2.46 mm in females, a short axis of 14.21 ± 2.19 mm in males and 12.15 ± 3.22 mm in females, a corridor length of 153.07 ± 11.99 mm in males and 151.11 ± 8.73 mm in females, and a proportional position of the optimal entry point in the long axis of the cancellous corridor of 35.96 ± 10.31% in males and 33.28 ± 7.2% in females. There were significant differences in the corridor long axis and corridor short axis between sexes (p < 0.05), and there were no significant differences in corridor length and proportional position of the optimal entry point in the long axis of the cancellous corridor between sexes (p > 0.05). The S2 cancellous corridor had a long axis of 17.58 ± 2.36 mm in males and 16 ± 2.64 mm in females, a short axis of 14.21 ± 2.19 mm in males and 13.14 ± 2.2 mm in females, a corridor length of 129.95 ± 0.89 mm in males and 136.5 ± 7.96 mm in females, and a proportional position of the optimal entry point in the long axis of the cancellous corridor of 46.77 ± 9.02% in males and 42.25 ± 11.95% in females. There were significant differences in the long axis, short axis and corridor length (p < 0.05). There was no significant difference in the proportional position of the optimal entry point in the long axis of the cancellous corridor (p > 0.05). A total of 20 transversal sacroiliac screws were successfully implanted into 10 patients with the assistance of locked navigation templates, and a total of 24 transversal sacroiliac screws were successfully implanted into 12 patients under C-arm fluoroscopy. There was a significant difference in surgical time (88 ± 14.76 min vs 102.5 ± 17.12 min, p = 0.048), radiation times (11.5 ± 1.78 vs 54.83 ± 6.59, p < 0.05) and screw grading between two groups (nineteen screws in grade 0, one screw in grade 1 and 0 screws in grade 2 vs fourteen screws in grade 0, 8 screws in grade 1 and 2 screws in grade 2, p = 0.005). All screw entry point deviations were shorter than the short axis of the cancellous corridor, and all screws were located completely within the cancellous corridor. Conclusion: Approximately 76% of males and females can accommodate screws with diameters of 7.3 mm in S1, and all persons can accommodate the same screw in S2. From the standard lateral perspective of the sacrum, the optimal entry point of the transverse screw is in the first 1/3 of the cancellous corridor for S1 and the centre of the cancellous corridor for S2. The patient-specific locked navigation template assisted in TSS placement with less operative time, less intraoperative fluoroscopy and higher safety of screw placement compared with traditional surgery.
- 13 July 2020
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 15 (1) , 1-11
Open AccessAnatomical conditions and patient-specific locked navigation templates for transverse sacroiliac screw placement: a retrospective study
Objective: To analyse the anatomical conditions of transverse sacroiliac screw (TSS) about the S1 and S2 segments in order to develop and validate a locked navigational template for TSS placement. Methods: A total of 22 patients with sacral fractures were involved in this study from May 2018 to February 2019. Patients were divided into two groups according to the surgery procedure: locked template group and conventional group. The CT data of 90 normal sacra were analysed. The long axis, short axis and lengths of TSS, cancellous corridors were measured through 3D modelling. A patient-specific locked navigation template based on simulated screws was designed and 3D printed and then used to assist in TSS placement. The operative time and radiation times were recorded. The Matta criteria and grading score were evaluated. The entry point deviation of the actual screw placement relative to the simulated screw placement was measured, and whether the whole screw was in the cancellous corridor was ob`served. Results: S1 screws with a diameter of 7.3 mm could be inserted into 69 pelvises, and S2 screws could be inserted in all pelvises. The S1 cancellous corridor had a long axis of 25.44 ± 3.32 mm in males and 22.91 ± 2.46 mm in females, a short axis of 14.21 ± 2.19 mm in males and 12.15 ± 3.22 mm in females, a corridor length of 153.07 ± 11.99 mm in males and 151.11 ± 8.73 mm in females, and a proportional position of the optimal entry point in the long axis of the cancellous corridor of 35.96 ± 10.31% in males and 33.28 ± 7.2% in females. There were significant differences in the corridor long axis and corridor short axis between sexes (p < 0.05), and there were no significant differences in corridor length and proportional position of the optimal entry point in the long axis of the cancellous corridor between sexes (p > 0.05). The S2 cancellous corridor had a long axis of 17.58 ± 2.36 mm in males and 16 ± 2.64 mm in females, a short axis of 14.21 ± 2.19 mm in males and 13.14 ± 2.2 mm in females, a corridor length of 129.95 ± 0.89 mm in males and 136.5 ± 7.96 mm in females, and a proportional position of the optimal entry point in the long axis of the cancellous corridor of 46.77 ± 9.02% in males and 42.25 ± 11.95% in females. There were significant differences in the long axis, short axis and corridor length (p < 0.05). There was no significant difference in the proportional position of the optimal entry point in the long axis of the cancellous corridor (p > 0.05). A total of 20 transversal sacroiliac screws were successfully implanted into 10 patients with the assistance of locked navigation templates, and a total of 24 transversal sacroiliac screws were successfully implanted into 12 patients under C-arm fluoroscopy. There was a significant difference in surgical time (88 ± 14.76 min vs 102.5 ± 17.12 min, p = 0.048), radiation times (11.5 ± 1.78 vs 54.83 ± 6.59, p < 0.05) and screw grading between two groups (nineteen screws in grade 0, one screw in grade 1 and 0 screws in grade 2 vs fourteen screws in grade 0, 8 screws in grade 1 and 2 screws in grade 2, p = 0.005). All screw entry point deviations were shorter than the short axis of the cancellous corridor, and all screws were located completely within the cancellous corridor. Conclusion: Approximately 76% of males and females can accommodate screws with diameters of 7.3 mm in S1, and all persons can accommodate the same screw in S2. From the standard lateral perspective of the sacrum, the optimal entry point of the transverse screw is in the first 1/3 of the cancellous corridor for S1 and the centre of the cancellous corridor for S2. The patient-specific locked navigation template assisted in TSS placement with less operative time, less intraoperative fluoroscopy and higher safety of screw placement compared with traditional surgery.